Haemolysis during cardiopulmonary bypass: an in vivo comparison of standard roller pumps, nonocclusive roller pumps and centrifugal pumps. 1999

S D Hansbro, and D A Sharpe, and R Catchpole, and K R Welsh, and C M Munsch, and J P McGoldrick, and P H Kay
Yorkshire Heart Centre, General Infirmary at Leeds, UK.

Cardiopulmonary bypass (CPB) involves the use of either an occlusive roller pump or centrifugal pump. Damage to blood elements, including haemolysis, may arise from occlusion when using a roller pump; the appropriate degree of occlusion has not yet been determined scientifically. Centrifugal and nonocclusive roller pumps are reputed to reduce haemolysis. The objective of this study was to compare haemolysis caused by a standard roller pump with a dynamically set nonocclusive roller pump and with a centrifugal pump. We prospectively randomized 60 patients undergoing routine coronary artery surgery into three groups: standard roller pump (STD, n = 20), dynamically set roller pump (DYN, n = 20), or centrifugal pump (CEN, n = 20). The level of plasma free haemoglobin (FHb) was measured preoperatively, and the rate of formation of FHb (in mg/dl/min) was determined at the end of the ischaemic phase and at the end of CPB. Cardiotomy suction blood was isolated for the ischaemic phase and returned before the end of CPB. It was found that there were no differences between the groups in demographic or operative variables. The rate of formation of FHb at the end of the ischaemic phase was similar for all groups (STD 0.108 +/- 0.10, DYN 0.117 +/- 0.08, CEN 0.129 +/- 0.07). At the end of CPB, after return of the cardiotomy suction blood, there was a significant (< 0.001) increase in the rate of formation of FHb in all groups. The increase was similar for each of the groups (STD 0.424 +/- 0.17, DYN 0.481 +/- 0.20, CEN 0.471 +/- 0.18). We conclude that the rates of haemolysis are similar for each of the pump types, and no benefit is conferred by the use of either a dynamically set roller pump or a centrifugal pump compared with the standard roller pump. The return of the cardiotomy suction blood to the circulation is the principal source of plasma free haemoglobin.

UI MeSH Term Description Entries
D007432 Intraoperative Period The period during a surgical operation. Intraoperative Periods,Period, Intraoperative,Periods, Intraoperative
D007958 Leukocyte Count The number of WHITE BLOOD CELLS per unit volume in venous BLOOD. A differential leukocyte count measures the relative numbers of the different types of white cells. Blood Cell Count, White,Differential Leukocyte Count,Leukocyte Count, Differential,Leukocyte Number,White Blood Cell Count,Count, Differential Leukocyte,Count, Leukocyte,Counts, Differential Leukocyte,Counts, Leukocyte,Differential Leukocyte Counts,Leukocyte Counts,Leukocyte Counts, Differential,Leukocyte Numbers,Number, Leukocyte,Numbers, Leukocyte
D008297 Male Males
D008875 Middle Aged An adult aged 45 - 64 years. Middle Age
D010976 Platelet Count The number of PLATELETS per unit volume in a sample of venous BLOOD. Blood Platelet Count,Blood Platelet Number,Platelet Number,Blood Platelet Counts,Blood Platelet Numbers,Count, Blood Platelet,Count, Platelet,Counts, Blood Platelet,Counts, Platelet,Number, Blood Platelet,Number, Platelet,Numbers, Blood Platelet,Numbers, Platelet,Platelet Count, Blood,Platelet Counts,Platelet Counts, Blood,Platelet Number, Blood,Platelet Numbers,Platelet Numbers, Blood
D004867 Equipment Design Methods and patterns of fabricating machines and related hardware. Design, Equipment,Device Design,Medical Device Design,Design, Medical Device,Designs, Medical Device,Device Design, Medical,Device Designs, Medical,Medical Device Designs,Design, Device,Designs, Device,Designs, Equipment,Device Designs,Equipment Designs
D004906 Erythrocyte Count The number of RED BLOOD CELLS per unit volume in a sample of venous BLOOD. Blood Cell Count, Red,Erythrocyte Number,Red Blood Cell Count,Count, Erythrocyte,Counts, Erythrocyte,Erythrocyte Counts,Erythrocyte Numbers
D005260 Female Females
D006355 Heart-Lung Machine Apparatus that provides mechanical circulatory support during open-heart surgery, by passing the heart to facilitate surgery on the organ. The basic function of the machine is to oxygenate the body's venous supply of blood and then pump it back into the arterial system. The machine also provides intracardiac suction, filtration, and temperature control. Some of the more important components of these machines include pumps, oxygenators, temperature regulators, and filters. (UMDNS, 1999) Heart Lung Machine,Heart-Lung Machines,Machine, Heart-Lung,Machines, Heart-Lung
D006400 Hematocrit The volume of packed RED BLOOD CELLS in a blood specimen. The volume is measured by centrifugation in a tube with graduated markings, or with automated blood cell counters. It is an indicator of erythrocyte status in disease. For example, ANEMIA shows a low value; POLYCYTHEMIA, a high value. Erythrocyte Volume, Packed,Packed Red-Cell Volume,Erythrocyte Volumes, Packed,Hematocrits,Packed Erythrocyte Volume,Packed Erythrocyte Volumes,Packed Red Cell Volume,Packed Red-Cell Volumes,Red-Cell Volume, Packed,Red-Cell Volumes, Packed,Volume, Packed Erythrocyte,Volume, Packed Red-Cell,Volumes, Packed Erythrocyte,Volumes, Packed Red-Cell

Related Publications

S D Hansbro, and D A Sharpe, and R Catchpole, and K R Welsh, and C M Munsch, and J P McGoldrick, and P H Kay
February 1998, The Annals of thoracic surgery,
S D Hansbro, and D A Sharpe, and R Catchpole, and K R Welsh, and C M Munsch, and J P McGoldrick, and P H Kay
November 2014, Artificial organs,
S D Hansbro, and D A Sharpe, and R Catchpole, and K R Welsh, and C M Munsch, and J P McGoldrick, and P H Kay
October 1997, Journal of cardiothoracic and vascular anesthesia,
S D Hansbro, and D A Sharpe, and R Catchpole, and K R Welsh, and C M Munsch, and J P McGoldrick, and P H Kay
April 1999, The Annals of thoracic surgery,
S D Hansbro, and D A Sharpe, and R Catchpole, and K R Welsh, and C M Munsch, and J P McGoldrick, and P H Kay
September 1997, Perfusion,
S D Hansbro, and D A Sharpe, and R Catchpole, and K R Welsh, and C M Munsch, and J P McGoldrick, and P H Kay
January 1995, Heart and vessels,
S D Hansbro, and D A Sharpe, and R Catchpole, and K R Welsh, and C M Munsch, and J P McGoldrick, and P H Kay
April 1984, Kyobu geka. The Japanese journal of thoracic surgery,
S D Hansbro, and D A Sharpe, and R Catchpole, and K R Welsh, and C M Munsch, and J P McGoldrick, and P H Kay
December 2006, Perfusion,
S D Hansbro, and D A Sharpe, and R Catchpole, and K R Welsh, and C M Munsch, and J P McGoldrick, and P H Kay
October 2015, Perfusion,
S D Hansbro, and D A Sharpe, and R Catchpole, and K R Welsh, and C M Munsch, and J P McGoldrick, and P H Kay
January 2004, ASAIO journal (American Society for Artificial Internal Organs : 1992),
Copied contents to your clipboard!