Electrophysiological effects of mexiletine in man. 1976

J C Roos, and A C Paalman, and A J Dunning

The electrophysiological effects of intravenous mexiletine in a dose of 200 to 250 mg given over 5 minutes, followed by continuous infusion of 60 to 90 mg per hour, were studied in 5 patients with normal conduction and in 20 patients with a variety of disturbances of impulse formation and conduction, by means of His bundle electrography, atrial pacing, and the extrastimulus method. In all but 2 patients the plasma level was above the lower therapeutic limit. Mexiletine had no consistent effects on sinus frequency and atrial refractoriness. The sinoatrial recovery time changed inconsistently in both directions; however, of the 5 patients in whom an increase was evident, 3 had sinus node dysfunction. In most patients mexiletine increased the AV nodal conduction time at paced atrial rates and shifted the Wenckebach point to a lower atrial rate. The effective refractory period of the AV node was not consistently influenced, while the functional refractory period increased in 12 out of 14 patients. The HV intervals increased by a mean of 11 ms in 8 patients and were unchanged in 17. Both the relative and effective refractory period of the His-Purkinje system increased after mexiletine. Non-cardiac side effects occurred in 7 out of 25 patients, and cardiac side effects, including one serious, in 2. The results indicate that mexiletine shares some electrophysiological properties with procainamide and quinidine, when given to patients with conduction defects, and that the drug should not be used in patients with pre-existing impairment of impulse formation or conduction. It has additional effects on AV nodal conduction which may be of value in the treatment of re-entrant tachycardias involving the AV node.

UI MeSH Term Description Entries
D008297 Male Males
D008801 Mexiletine Antiarrhythmic agent pharmacologically similar to LIDOCAINE. It may have some anticonvulsant properties. KO-1173,KO1173,KOE-1173,Mexiletene,Mexiletine Hydrochloride,Mexitil,Mexitil PL,Mexityl,Novo-Mexiletine,KO 1173,KOE 1173,KOE1173,Novo Mexiletine
D008875 Middle Aged An adult aged 45 - 64 years. Middle Age
D010138 Pacemaker, Artificial A device designed to stimulate, by electric impulses, contraction of the heart muscles. It may be temporary (external) or permanent (internal or internal-external). Cardiac Pacemaker, Artificial,Artificial Cardiac Pacemaker,Artificial Cardiac Pacemakers,Artificial Pacemaker,Artificial Pacemakers,Cardiac Pacemakers, Artificial,Pacemaker, Artificial Cardiac,Pacemakers, Artificial,Pacemakers, Artificial Cardiac
D011437 Propylamines Derivatives of propylamine (the structural formula NH2CH2CH2CH3).
D011690 Purkinje Fibers Modified cardiac muscle fibers composing the terminal portion of the heart conduction system. Purkinje Fiber,Fiber, Purkinje,Fibers, Purkinje
D002036 Bundle of His Small band of specialized CARDIAC MUSCLE fibers that originates in the ATRIOVENTRICULAR NODE and extends into the membranous part of the interventricular septum. The bundle of His, consisting of the left and the right bundle branches, conducts the electrical impulses to the HEART VENTRICLES in generation of MYOCARDIAL CONTRACTION. Atrioventricular Bundle,Anterior Fascicle,Kent-His Bundle,Left Bundle Branch of His,Posterior Fascicle,Right Bundle Branch of His,Atrioventricular Bundles,Bundle, Atrioventricular,Bundle, Kent-His,Bundles, Atrioventricular,Fascicle, Anterior,Fascicle, Posterior,His Bundle,Kent His Bundle
D003864 Depression, Chemical The decrease in a measurable parameter of a PHYSIOLOGICAL PROCESS, including cellular, microbial, and plant; immunological, cardiovascular, respiratory, reproductive, urinary, digestive, neural, musculoskeletal, ocular, and skin physiological processes; or METABOLIC PROCESS, including enzymatic and other pharmacological processes, by a drug or other chemical. Chemical Depression,Chemical Depressions,Depressions, Chemical
D004562 Electrocardiography Recording of the moment-to-moment electromotive forces of the HEART as projected onto various sites on the body's surface, delineated as a scalar function of time. The recording is monitored by a tracing on slow moving chart paper or by observing it on a cardioscope, which is a CATHODE RAY TUBE DISPLAY. 12-Lead ECG,12-Lead EKG,12-Lead Electrocardiography,Cardiography,ECG,EKG,Electrocardiogram,Electrocardiograph,12 Lead ECG,12 Lead EKG,12 Lead Electrocardiography,12-Lead ECGs,12-Lead EKGs,12-Lead Electrocardiographies,Cardiographies,ECG, 12-Lead,EKG, 12-Lead,Electrocardiograms,Electrocardiographies, 12-Lead,Electrocardiographs,Electrocardiography, 12-Lead
D005260 Female Females

Related Publications

J C Roos, and A C Paalman, and A J Dunning
January 1977, Postgraduate medical journal,
J C Roos, and A C Paalman, and A J Dunning
September 1991, The Journal of pharmacy and pharmacology,
J C Roos, and A C Paalman, and A J Dunning
December 1978, Archives des maladies du coeur et des vaisseaux,
J C Roos, and A C Paalman, and A J Dunning
December 1983, Kokyu to junkan. Respiration & circulation,
J C Roos, and A C Paalman, and A J Dunning
October 1990, Journal of cardiovascular pharmacology,
J C Roos, and A C Paalman, and A J Dunning
January 1986, Archivos del Instituto de Cardiologia de Mexico,
J C Roos, and A C Paalman, and A J Dunning
May 2021, Scientific reports,
J C Roos, and A C Paalman, and A J Dunning
August 1979, The Journal of pharmacology and experimental therapeutics,
J C Roos, and A C Paalman, and A J Dunning
June 1984, Archives des maladies du coeur et des vaisseaux,
J C Roos, and A C Paalman, and A J Dunning
October 2004, Therapeutic drug monitoring,
Copied contents to your clipboard!