Gas chromatographic-mass spectrometric determination of total homocysteine in human plasma by stable isotope dilution: method and clinical applications. 1999

V Ducros, and D Schmitt, and G Pernod, and H Faure, and B Polack, and A Favier
Laboratoire de Biochimie C, CHU de Grenoble, France.

The detection and quantitation of slight increases of plasma homocysteine levels is of growing interest. This has prompted us to develop a highly sensitive and accurate capillary gas chromatography-mass spectrometry (GC-MS) method. The method proved to be highly sensitive (DL=0.17 micromol/l) with between- and within-run precision less than 6% and 7%, respectively. Reference values of plasma total homocysteine have been determined for men (n=39) and women (n=36), showing a significant difference (P=0.003) between gender. Preliminary results in cerebrovascular accidents and in venous thrombosis are presented.

UI MeSH Term Description Entries
D007554 Isotopes Atomic species differing in mass number but having the same atomic number. (Grant & Hackh's Chemical Dictionary, 5th ed) Isotope
D008297 Male Males
D008401 Gas Chromatography-Mass Spectrometry A microanalytical technique combining mass spectrometry and gas chromatography for the qualitative as well as quantitative determinations of compounds. Chromatography, Gas-Liquid-Mass Spectrometry,Chromatography, Gas-Mass Spectrometry,GCMS,Spectrometry, Mass-Gas Chromatography,Spectrum Analysis, Mass-Gas Chromatography,Gas-Liquid Chromatography-Mass Spectrometry,Mass Spectrometry-Gas Chromatography,Chromatography, Gas Liquid Mass Spectrometry,Chromatography, Gas Mass Spectrometry,Chromatography, Mass Spectrometry-Gas,Chromatography-Mass Spectrometry, Gas,Chromatography-Mass Spectrometry, Gas-Liquid,Gas Chromatography Mass Spectrometry,Gas Liquid Chromatography Mass Spectrometry,Mass Spectrometry Gas Chromatography,Spectrometries, Mass-Gas Chromatography,Spectrometry, Gas Chromatography-Mass,Spectrometry, Gas-Liquid Chromatography-Mass,Spectrometry, Mass Gas Chromatography,Spectrometry-Gas Chromatography, Mass,Spectrum Analysis, Mass Gas Chromatography
D008875 Middle Aged An adult aged 45 - 64 years. Middle Age
D012016 Reference Values The range or frequency distribution of a measurement in a population (of organisms, organs or things) that has not been selected for the presence of disease or abnormality. Normal Range,Normal Values,Reference Ranges,Normal Ranges,Normal Value,Range, Normal,Range, Reference,Ranges, Normal,Ranges, Reference,Reference Range,Reference Value,Value, Normal,Value, Reference,Values, Normal,Values, Reference
D002138 Calibration Determination, by measurement or comparison with a standard, of the correct value of each scale reading on a meter or other measuring instrument; or determination of the settings of a control device that correspond to particular values of voltage, current, frequency or other output. Calibrations
D002561 Cerebrovascular Disorders A spectrum of pathological conditions of impaired blood flow in the brain. They can involve vessels (ARTERIES or VEINS) in the CEREBRUM, the CEREBELLUM, and the BRAIN STEM. Major categories include INTRACRANIAL ARTERIOVENOUS MALFORMATIONS; BRAIN ISCHEMIA; CEREBRAL HEMORRHAGE; and others. Brain Vascular Disorders,Intracranial Vascular Disorders,Vascular Diseases, Intracranial,Cerebrovascular Diseases,Cerebrovascular Insufficiency,Cerebrovascular Occlusion,Brain Vascular Disorder,Cerebrovascular Disease,Cerebrovascular Disorder,Cerebrovascular Insufficiencies,Cerebrovascular Occlusions,Disease, Cerebrovascular,Diseases, Cerebrovascular,Insufficiencies, Cerebrovascular,Insufficiency, Cerebrovascular,Intracranial Vascular Disease,Intracranial Vascular Diseases,Intracranial Vascular Disorder,Occlusion, Cerebrovascular,Occlusions, Cerebrovascular,Vascular Disease, Intracranial,Vascular Disorder, Brain,Vascular Disorder, Intracranial,Vascular Disorders, Brain,Vascular Disorders, Intracranial
D005260 Female Females
D006710 Homocysteine A thiol-containing amino acid formed by a demethylation of METHIONINE. 2-amino-4-mercaptobutyric acid,Homocysteine, L-Isomer,2 amino 4 mercaptobutyric acid,Homocysteine, L Isomer,L-Isomer Homocysteine
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man

Related Publications

V Ducros, and D Schmitt, and G Pernod, and H Faure, and B Polack, and A Favier
June 1993, Journal of chromatography,
V Ducros, and D Schmitt, and G Pernod, and H Faure, and B Polack, and A Favier
August 1973, Biochemical medicine,
V Ducros, and D Schmitt, and G Pernod, and H Faure, and B Polack, and A Favier
September 1999, Clinical chemistry,
V Ducros, and D Schmitt, and G Pernod, and H Faure, and B Polack, and A Favier
July 1996, Journal of chromatography. B, Biomedical applications,
V Ducros, and D Schmitt, and G Pernod, and H Faure, and B Polack, and A Favier
January 1996, Analytical biochemistry,
V Ducros, and D Schmitt, and G Pernod, and H Faure, and B Polack, and A Favier
June 1996, Journal of mass spectrometry : JMS,
V Ducros, and D Schmitt, and G Pernod, and H Faure, and B Polack, and A Favier
July 1991, Clinica chimica acta; international journal of clinical chemistry,
V Ducros, and D Schmitt, and G Pernod, and H Faure, and B Polack, and A Favier
October 1988, Biomedical & environmental mass spectrometry,
V Ducros, and D Schmitt, and G Pernod, and H Faure, and B Polack, and A Favier
February 1979, Analytical chemistry,
V Ducros, and D Schmitt, and G Pernod, and H Faure, and B Polack, and A Favier
September 2002, Analytical biochemistry,
Copied contents to your clipboard!