Reliability of a new device to assess the oxygen consumption of human respiratory muscles. 1999

S Ahmaidi, and D Comte, and N Topin, and M Hayot, and S Delanaud, and M Ramonatxo, and N His, and G Vardon, and M Freville, and J P Libert, and C Préfaut
TEF-Adaptations Physiologiques et Comportementales, Faculté de Médecine (EA 2088), Université de Picardie Jules Verne, Amiens, France. Said.Ahmaidi@ca.u-picardie.fr

OBJECTIVE This study tests the reliability of a new device for assessing the oxygen consumption of the respiratory muscles (VO2 resp.). METHODS Fourteen healthy male volunteers participated in the study. The device consists of an expandable external ventilatory dead space created with pieces of plastic tubing and a spirometer filled with 100% oxygen. It also incorporates a carbon dioxide absorber. Total VO2 (VO2 tot.) was recorded from the spirometric closed circuit and ventilation (V(E)), from the spirometer tracing. For each subject the test procedure was carried out in duplicate (T1 and T2) after an overnight fast. The dead space was increased at a constant rate of 260 mL every 90 s, and VO2 tot. and V(E) increased progressively. Because log VO2 tot. was linearly related to V(E), we calculated the slope value (log VO2-V(E)) and the Y-intercept (VE = 0) of the semilog regression representing, respectively, VO2 resp. and metabolic VO2 (VO2 met.). RESULTS When compared with values in the literature, these values did not differ from those recorded in subjects of a similar age group. The VO2 resp. and VO2 met. calculated in T1 and T2 were not different (VO2 resp. = 0.0066 +/- 0.0005 for T1 vs 0.0067 +/- 0.0005 log mL x min(-1)/L x min(-1) for T2 and VO2 met. = 269.3 +/- 28.6 for T1 vs 281.9 +/- 24.1 mL x min(-1) for T2). The coefficients of variation were: 25% at T1 and 23% at T2 for VO2 resp. and 34% at T1 and 29% at T2 for VO2 met. Moreover, significant correlations (r = 0.96, P < 0.001 for VO2 resp., r = 0.95, P < 0.001 for VO2 met.), high coefficients of determination (r2 = 0.92 for VO2 resp., r2 = 0.90 for VO2 met.) and negligible SEE (0.0005 for VO2 resp., 0.2 mL x min(-1) for VO2 met.) were found between the two tests. When we plotted the mean values of VO2 resp. and VO2 met. measured at T1 and T2 against their respective differences, more than 95% of the slight differences ranged between the limits defined by mean value +/- 2 SD, reflecting the small discrepancy between duplicate measurements. CONCLUSIONS The results confirm that the test performed with this device is useful and reliable for assessing the VO2 resp. in healthy subjects.

UI MeSH Term Description Entries
D008297 Male Males
D008991 Monitoring, Physiologic The continuous measurement of physiological processes, blood pressure, heart rate, renal output, reflexes, respiration, etc., in a patient or experimental animal; includes pharmacologic monitoring, the measurement of administered drugs or their metabolites in the blood, tissues, or urine. Patient Monitoring,Monitoring, Physiological,Physiologic Monitoring,Monitoring, Patient,Physiological Monitoring
D010101 Oxygen Consumption The rate at which oxygen is used by a tissue; microliters of oxygen STPD used per milligram of tissue per hour; the rate at which oxygen enters the blood from alveolar gas, equal in the steady state to the consumption of oxygen by tissue metabolism throughout the body. (Stedman, 25th ed, p346) Consumption, Oxygen,Consumptions, Oxygen,Oxygen Consumptions
D012129 Respiratory Function Tests Measurement of the various processes involved in the act of respiration: inspiration, expiration, oxygen and carbon dioxide exchange, lung volume and compliance, etc. Lung Function Tests,Pulmonary Function Tests,Function Test, Pulmonary,Function Tests, Pulmonary,Pulmonary Function Test,Test, Pulmonary Function,Tests, Pulmonary Function,Function Test, Lung,Function Test, Respiratory,Function Tests, Lung,Function Tests, Respiratory,Lung Function Test,Respiratory Function Test,Test, Lung Function,Test, Respiratory Function,Tests, Lung Function,Tests, Respiratory Function
D012132 Respiratory Muscles These include the muscles of the DIAPHRAGM and the INTERCOSTAL MUSCLES. Ventilatory Muscles,Respiratory Muscle,Muscle, Respiratory,Muscle, Ventilatory,Muscles, Respiratory,Muscles, Ventilatory,Ventilatory Muscle
D004867 Equipment Design Methods and patterns of fabricating machines and related hardware. Design, Equipment,Device Design,Medical Device Design,Design, Medical Device,Designs, Medical Device,Device Design, Medical,Device Designs, Medical,Medical Device Designs,Design, Device,Designs, Device,Designs, Equipment,Device Designs,Equipment Designs
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D000328 Adult A person having attained full growth or maturity. Adults are of 19 through 44 years of age. For a person between 19 and 24 years of age, YOUNG ADULT is available. Adults
D015203 Reproducibility of Results The statistical reproducibility of measurements (often in a clinical context), including the testing of instrumentation or techniques to obtain reproducible results. The concept includes reproducibility of physiological measurements, which may be used to develop rules to assess probability or prognosis, or response to a stimulus; reproducibility of occurrence of a condition; and reproducibility of experimental results. Reliability and Validity,Reliability of Result,Reproducibility Of Result,Reproducibility of Finding,Validity of Result,Validity of Results,Face Validity,Reliability (Epidemiology),Reliability of Results,Reproducibility of Findings,Test-Retest Reliability,Validity (Epidemiology),Finding Reproducibilities,Finding Reproducibility,Of Result, Reproducibility,Of Results, Reproducibility,Reliabilities, Test-Retest,Reliability, Test-Retest,Result Reliabilities,Result Reliability,Result Validities,Result Validity,Result, Reproducibility Of,Results, Reproducibility Of,Test Retest Reliability,Validity and Reliability,Validity, Face
D016014 Linear Models Statistical models in which the value of a parameter for a given value of a factor is assumed to be equal to a + bx, where a and b are constants. The models predict a linear regression. Linear Regression,Log-Linear Models,Models, Linear,Linear Model,Linear Regressions,Log Linear Models,Log-Linear Model,Model, Linear,Model, Log-Linear,Models, Log-Linear,Regression, Linear,Regressions, Linear

Related Publications

S Ahmaidi, and D Comte, and N Topin, and M Hayot, and S Delanaud, and M Ramonatxo, and N His, and G Vardon, and M Freville, and J P Libert, and C Préfaut
July 2002, Foot & ankle international,
S Ahmaidi, and D Comte, and N Topin, and M Hayot, and S Delanaud, and M Ramonatxo, and N His, and G Vardon, and M Freville, and J P Libert, and C Préfaut
November 1981, Schweizerische medizinische Wochenschrift,
S Ahmaidi, and D Comte, and N Topin, and M Hayot, and S Delanaud, and M Ramonatxo, and N His, and G Vardon, and M Freville, and J P Libert, and C Préfaut
March 1994, Chest,
S Ahmaidi, and D Comte, and N Topin, and M Hayot, and S Delanaud, and M Ramonatxo, and N His, and G Vardon, and M Freville, and J P Libert, and C Préfaut
July 1990, Journal of applied physiology (Bethesda, Md. : 1985),
S Ahmaidi, and D Comte, and N Topin, and M Hayot, and S Delanaud, and M Ramonatxo, and N His, and G Vardon, and M Freville, and J P Libert, and C Préfaut
December 2021, International journal of molecular sciences,
S Ahmaidi, and D Comte, and N Topin, and M Hayot, and S Delanaud, and M Ramonatxo, and N His, and G Vardon, and M Freville, and J P Libert, and C Préfaut
August 2019, Sports (Basel, Switzerland),
S Ahmaidi, and D Comte, and N Topin, and M Hayot, and S Delanaud, and M Ramonatxo, and N His, and G Vardon, and M Freville, and J P Libert, and C Préfaut
February 1959, Clinical science,
S Ahmaidi, and D Comte, and N Topin, and M Hayot, and S Delanaud, and M Ramonatxo, and N His, and G Vardon, and M Freville, and J P Libert, and C Préfaut
March 1959, The Journal of clinical investigation,
S Ahmaidi, and D Comte, and N Topin, and M Hayot, and S Delanaud, and M Ramonatxo, and N His, and G Vardon, and M Freville, and J P Libert, and C Préfaut
December 1958, Minerva medica,
S Ahmaidi, and D Comte, and N Topin, and M Hayot, and S Delanaud, and M Ramonatxo, and N His, and G Vardon, and M Freville, and J P Libert, and C Préfaut
September 2011, Annals of the New York Academy of Sciences,
Copied contents to your clipboard!