LIAISON Ferritin--an automated chemiluminescent immunoassay for the determination of Ferritin. 1999

B König, and M Oed, and A Kunz, and R Schlett, and M Mack

An immunoassay utilizing chemiluminescence and paramagnetic particles has been developed for the new fully automated random access LIAISON immunoanalyzer. The LIAISON Ferritin assay is a two-site immunoluminometric one-step assay using two highly specific monoclonal antibodies. A specially designed unique Reagent Integral contains all specific reagents. The cooled reagent compartment guarantees an on-board stability of at least 4 weeks. The assay works with a 2-point calibrated master curve. To perform, the assay, 10 microliters sample is added to 300 microliters tracer and 20 microliters antibody-coated magnetic particles. After 10 min incubation the particles are separated, washed and the chemiluminescent signal is generated. The time to first result is only 15 min. The assay with a unique extended standard range up to 3,000 ng/ml shows no high dose hook effect up to 150,000 ng/ml (spiked sera). The cross-reactivity to human liver ferritin is 100%, to human spleen ferritin 66% and to human heart ferritin 8%. Precision (within-run < 3%; between-run < 5%), linearity, recovery and sensitivity (< 0.2 ng/ml) are excellent. The assay shows a very good correlation to LlA-mat Ferritin (r = 0.994). In summary the LIAISON Ferritin run on the new LIAISON immunoanalyzer and is a very rapid and accurate method rapidly providing reliable results.

UI MeSH Term Description Entries
D007118 Immunoassay A technique using antibodies for identifying or quantifying a substance. Usually the substance being studied serves as antigen both in antibody production and in measurement of antibody by the test substance. Immunochromatographic Assay,Assay, Immunochromatographic,Assays, Immunochromatographic,Immunoassays,Immunochromatographic Assays
D008163 Luminescent Measurements Techniques used for determining the values of photometric parameters of light resulting from LUMINESCENCE. Bioluminescence Measurements,Bioluminescent Assays,Bioluminescent Measurements,Chemiluminescence Measurements,Chemiluminescent Assays,Chemiluminescent Measurements,Chemoluminescence Measurements,Luminescence Measurements,Luminescent Assays,Luminescent Techniques,Phosphorescence Measurements,Phosphorescent Assays,Phosphorescent Measurements,Assay, Bioluminescent,Assay, Chemiluminescent,Assay, Luminescent,Assay, Phosphorescent,Assays, Bioluminescent,Assays, Chemiluminescent,Assays, Luminescent,Assays, Phosphorescent,Bioluminescence Measurement,Bioluminescent Assay,Bioluminescent Measurement,Chemiluminescence Measurement,Chemiluminescent Assay,Chemiluminescent Measurement,Chemoluminescence Measurement,Luminescence Measurement,Luminescent Assay,Luminescent Measurement,Luminescent Technique,Measurement, Bioluminescence,Measurement, Bioluminescent,Measurement, Chemiluminescence,Measurement, Chemiluminescent,Measurement, Chemoluminescence,Measurement, Luminescence,Measurement, Luminescent,Measurement, Phosphorescence,Measurement, Phosphorescent,Measurements, Bioluminescence,Measurements, Bioluminescent,Measurements, Chemiluminescence,Measurements, Chemiluminescent,Measurements, Chemoluminescence,Measurements, Luminescence,Measurements, Luminescent,Measurements, Phosphorescence,Measurements, Phosphorescent,Phosphorescence Measurement,Phosphorescent Assay,Phosphorescent Measurement,Technique, Luminescent,Techniques, Luminescent
D008297 Male Males
D012016 Reference Values The range or frequency distribution of a measurement in a population (of organisms, organs or things) that has not been selected for the presence of disease or abnormality. Normal Range,Normal Values,Reference Ranges,Normal Ranges,Normal Value,Range, Normal,Range, Reference,Ranges, Normal,Ranges, Reference,Reference Range,Reference Value,Value, Normal,Value, Reference,Values, Normal,Values, Reference
D002138 Calibration Determination, by measurement or comparison with a standard, of the correct value of each scale reading on a meter or other measuring instrument; or determination of the settings of a control device that correspond to particular values of voltage, current, frequency or other output. Calibrations
D005260 Female Females
D005293 Ferritins Iron-containing proteins that are widely distributed in animals, plants, and microorganisms. Their major function is to store IRON in a nontoxic bioavailable form. Each ferritin molecule consists of ferric iron in a hollow protein shell (APOFERRITINS) made of 24 subunits of various sequences depending on the species and tissue types. Basic Isoferritin,Ferritin,Isoferritin,Isoferritin, Basic
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D001322 Autoanalysis Method of analyzing chemicals using automation. Autoanalyses
D012680 Sensitivity and Specificity Binary classification measures to assess test results. Sensitivity or recall rate is the proportion of true positives. Specificity is the probability of correctly determining the absence of a condition. (From Last, Dictionary of Epidemiology, 2d ed) Specificity,Sensitivity,Specificity and Sensitivity

Related Publications

B König, and M Oed, and A Kunz, and R Schlett, and M Mack
January 1999, Anticancer research,
B König, and M Oed, and A Kunz, and R Schlett, and M Mack
January 1999, Anticancer research,
B König, and M Oed, and A Kunz, and R Schlett, and M Mack
January 2000, Clinical laboratory,
B König, and M Oed, and A Kunz, and R Schlett, and M Mack
May 2010, Annals of clinical biochemistry,
B König, and M Oed, and A Kunz, and R Schlett, and M Mack
September 2012, Journal of veterinary diagnostic investigation : official publication of the American Association of Veterinary Laboratory Diagnosticians, Inc,
B König, and M Oed, and A Kunz, and R Schlett, and M Mack
July 2017, Clinical chemistry and laboratory medicine,
B König, and M Oed, and A Kunz, and R Schlett, and M Mack
July 2013, Immunologic research,
B König, and M Oed, and A Kunz, and R Schlett, and M Mack
January 2022, Diagnostics (Basel, Switzerland),
B König, and M Oed, and A Kunz, and R Schlett, and M Mack
January 2003, Journal of clinical laboratory analysis,
B König, and M Oed, and A Kunz, and R Schlett, and M Mack
February 2004, Journal of virological methods,
Copied contents to your clipboard!