Acute and temporary ventricular support with BioMedicus centrifugal pump. 1999

G P Noon, and J A Lafuente, and S Irwin
Department of Surgery, Baylor College of Medicine, The Methodist Hospital, Houston, Texas, USA.

BACKGROUND Short-term ventricular and pulmonary support can be provided by the Medtronic BioMedicus (Eden Prairie, MN) centrifugal pump, which is available in most cardiovascular surgery centers. This versatile pump can provide support during cardiopulmonary resuscitation, cardiopulmonary bypass, extracorporeal membrane oxygenation, and ventricular assistance. A common use of the pump is to provide ventricular assistance for patients after cardiotomy or cardiogenic shock. METHODS From January 1986 to September 1995, 141 patients at The Methodist Hospital in Houston, Texas were placed on the BioMedicus centrifugal pump after postcardiotomy cardiac failure. Patient treatment and postimplant complications are discussed. RESULTS Fifty-four percent of the patients were weaned; however, only 22% survived to discharge. There was a very high mortality rate in the early stage after support was discontinued, after weaning, and after device removal. CONCLUSIONS A high incidence of complications and death is likely related to the period of attempted weaning from cardiopulmonary bypass before the initiation of ventricular support. When weaning a patient from the pump during cardiopulmonary bypass or during ventricular assistance, it is important to optimize preload, after-load, ventricular function, and cardiac rhythm. In patients who have had postcardiotomy support, avoiding fluid overload, low colloid oncotic pressure, hypoperfusion, and use of excessive inotropic and vasoactive medications improve results.

UI MeSH Term Description Entries
D008297 Male Males
D008875 Middle Aged An adult aged 45 - 64 years. Middle Age
D011183 Postoperative Complications Pathologic processes that affect patients after a surgical procedure. They may or may not be related to the disease for which the surgery was done, and they may or may not be direct results of the surgery. Complication, Postoperative,Complications, Postoperative,Postoperative Complication
D005260 Female Females
D006333 Heart Failure A heterogeneous condition in which the heart is unable to pump out sufficient blood to meet the metabolic need of the body. Heart failure can be caused by structural defects, functional abnormalities (VENTRICULAR DYSFUNCTION), or a sudden overload beyond its capacity. Chronic heart failure is more common than acute heart failure which results from sudden insult to cardiac function, such as MYOCARDIAL INFARCTION. Cardiac Failure,Heart Decompensation,Congestive Heart Failure,Heart Failure, Congestive,Heart Failure, Left-Sided,Heart Failure, Right-Sided,Left-Sided Heart Failure,Myocardial Failure,Right-Sided Heart Failure,Decompensation, Heart,Heart Failure, Left Sided,Heart Failure, Right Sided,Left Sided Heart Failure,Right Sided Heart Failure
D006353 Heart-Assist Devices Small pumps, often implantable, designed for temporarily assisting the heart, usually the LEFT VENTRICLE, to pump blood. They consist of a pumping chamber and a power source, which may be partially or totally external to the body and activated by electromagnetic motors. Artificial Ventricle,Heart Assist Device,Heart Ventricle, Artificial,Pumps, Heart-Assist,Vascular-Assist Device,Vascular-Assist Devices,Ventricle-Assist Device,Ventricular Assist Device,Artificial Heart Ventricle,Artificial Heart Ventricles,Artificial Ventricles,Assist Device, Heart,Assist Device, Ventricular,Assist Devices, Heart,Assist Devices, Ventricular,Device, Heart Assist,Device, Heart-Assist,Device, Vascular-Assist,Device, Ventricle-Assist,Device, Ventricular Assist,Devices, Heart Assist,Devices, Heart-Assist,Devices, Vascular-Assist,Devices, Ventricle-Assist,Devices, Ventricular Assist,Heart Assist Devices,Heart Ventricles, Artificial,Heart-Assist Device,Heart-Assist Pump,Heart-Assist Pumps,Pump, Heart-Assist,Pumps, Heart Assist,Vascular Assist Device,Vascular Assist Devices,Ventricle Assist Device,Ventricle, Artificial,Ventricle, Artificial Heart,Ventricle-Assist Devices,Ventricles, Artificial,Ventricles, Artificial Heart,Ventricular Assist Devices
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D000293 Adolescent A person 13 to 18 years of age. Adolescence,Youth,Adolescents,Adolescents, Female,Adolescents, Male,Teenagers,Teens,Adolescent, Female,Adolescent, Male,Female Adolescent,Female Adolescents,Male Adolescent,Male Adolescents,Teen,Teenager,Youths
D000328 Adult A person having attained full growth or maturity. Adults are of 19 through 44 years of age. For a person between 19 and 24 years of age, YOUNG ADULT is available. Adults
D000368 Aged A person 65 years of age or older. For a person older than 79 years, AGED, 80 AND OVER is available. Elderly

Related Publications

G P Noon, and J A Lafuente, and S Irwin
March 2005, Asian cardiovascular & thoracic annals,
G P Noon, and J A Lafuente, and S Irwin
July 1995, Artificial organs,
G P Noon, and J A Lafuente, and S Irwin
September 1994, The International journal of artificial organs,
G P Noon, and J A Lafuente, and S Irwin
September 1989, Canadian journal of surgery. Journal canadien de chirurgie,
G P Noon, and J A Lafuente, and S Irwin
January 2012, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery,
G P Noon, and J A Lafuente, and S Irwin
October 1987, The Annals of thoracic surgery,
G P Noon, and J A Lafuente, and S Irwin
January 2006, Seminars in thoracic and cardiovascular surgery. Pediatric cardiac surgery annual,
G P Noon, and J A Lafuente, and S Irwin
May 2015, Kyobu geka. The Japanese journal of thoracic surgery,
Copied contents to your clipboard!