Antegrade locked nailing for humeral shaft fractures. 1999

J Lin, and S M Hou
Department of Orthopedic Surgery, National Taiwan University Hospital, Taipei, Taiwan.

Treatment results of antegrade locked nailing of acute humeral shaft fractures, including union rate and recovery of shoulder function, have been inconsistent. This led the current authors to hypothesize that implant design and surgical techniques might account for this inconsistency. In the current study, 47 fractures (38 acute; nine pathologic) in 47 patients achieved union with the techniques of closed nailing, short to long segment nailing, and fracture compression. Satisfactory recovery of shoulder function occurred because of minimal surgical trauma, prevention of impingement by the nail or locking screws, and prevention of axillary nerve injury or comminution of the humeral head. Forty-seven patients with 38 acute fractures and nine pathologic fractures were treated with humeral locked nails. Mean followup time was 21.4 months. With a single operation, all 38 acute fractures proceeded to eventual union; the average time to union was 7.8 weeks. Thirty-five patients had excellent or satisfactory recovery of shoulder function. Complications included slipout of the proximal screw, nail breakage, fragment displacement, and transient postoperative radial nerve palsy. All nine patients with pathologic fractures had substantial pain relief and increased arm function after surgery. The current study shows the reliability of antegrade locked nailing for proximal and middle third fractures of the humeral shaft.

UI MeSH Term Description Entries
D007431 Intraoperative Complications Complications that affect patients during surgery. They may or may not be associated with the disease for which the surgery is done, or within the same surgical procedure. Peroperative Complications,Surgical Injuries,Complication, Intraoperative,Complication, Peroperative,Injuries, Surgical,Complications, Intraoperative,Complications, Peroperative,Injury, Surgical,Intraoperative Complication,Peroperative Complication,Surgical Injury
D008297 Male Males
D008875 Middle Aged An adult aged 45 - 64 years. Middle Age
D010243 Paralysis A general term most often used to describe severe or complete loss of muscle strength due to motor system disease from the level of the cerebral cortex to the muscle fiber. This term may also occasionally refer to a loss of sensory function. (From Adams et al., Principles of Neurology, 6th ed, p45) Palsy,Plegia,Todd Paralysis,Todd's Paralysis,Palsies,Paralyses,Paralysis, Todd,Paralysis, Todd's,Plegias,Todds Paralysis
D011826 Radial Nerve A major nerve of the upper extremity. In humans the fibers of the radial nerve originate in the lower cervical and upper thoracic spinal cord (usually C5 to T1), travel via the posterior cord of the brachial plexus, and supply motor innervation to extensor muscles of the arm and cutaneous sensory fibers to extensor regions of the arm and hand. Nerve, Radial,Nerves, Radial,Radial Nerves
D001863 Bone Screws Specialized devices used in ORTHOPEDIC SURGERY to repair bone fractures. Bone Screw,Screw, Bone,Screws, Bone
D004204 Joint Dislocations Displacement of bones from their normal positions at a joint. Inferior Dislocation,Joint Subluxations,Luxatio Erecta,Dislocation, Joint,Dislocations, Joint,Inferior Dislocations,Joint Dislocation,Joint Subluxation,Subluxation, Joint,Subluxations, Joint
D004867 Equipment Design Methods and patterns of fabricating machines and related hardware. Design, Equipment,Device Design,Medical Device Design,Design, Medical Device,Designs, Medical Device,Device Design, Medical,Device Designs, Medical,Medical Device Designs,Design, Device,Designs, Device,Designs, Equipment,Device Designs,Equipment Designs
D004868 Equipment Failure Failure of equipment to perform to standard. The failure may be due to defects or improper use. Defects, Equipment,Device Failure,Failure, Equipment,Malfunction, Equipment,Medical Device Failure,Misuse, Equipment,Device Failure, Medical,Device Failures, Medical,Failure, Medical Device,Failures, Medical Device,Defect, Equipment,Device Failures,Equipment Defect,Equipment Defects,Equipment Failures,Equipment Malfunction,Equipment Malfunctions,Equipment Misuse,Equipment Misuses,Failure, Device,Failures, Device,Failures, Equipment,Malfunctions, Equipment,Misuses, Equipment
D005260 Female Females

Related Publications

J Lin, and S M Hou
January 2007, Orthopedics,
J Lin, and S M Hou
August 2012, Musculoskeletal surgery,
J Lin, and S M Hou
January 2004, Journal of orthopaedic science : official journal of the Japanese Orthopaedic Association,
J Lin, and S M Hou
July 1995, The Journal of bone and joint surgery. British volume,
J Lin, and S M Hou
May 1998, Clinical orthopaedics and related research,
J Lin, and S M Hou
April 2021, Operative Orthopadie und Traumatologie,
J Lin, and S M Hou
January 1999, International orthopaedics,
J Lin, and S M Hou
December 2012, Journal of orthopaedic surgery (Hong Kong),
Copied contents to your clipboard!