[Radiation exposure during spiral-CT of the paranasal sinuses]. 2000

F Dammann, and E Momino-Traserra, and C Remy, and P L Pereira, and I Baumann, and A Koitschev, and C D Claussen
Abt. f. Radiologische Diagnostik, Radiologische Universitätsklinik Tübingen. florian.dammann@med.uni-tuebingen.de

OBJECTIVE Determination of the radiation doses in spiral CT of the paranasal sinuses using a variety of mAs values and scan protocols. METHODS CT examinations of the paranasal sinuses were performed using an Alderson-Rando phantom. Radiation dose was determined by LiF-TLD at the level of high risk organs in the head and neck region for combinations of different scan parameters (2/3, 3/3, 3/4 mm) and decreasing charges (200, 150, 100, 50, 25 mAs) on a spiral CT. Additional measurements were performed on three other CT scanners using the 2/3 mm protocol at 50 mAs, and a single slice technique (5/5 mm) on one scanner. RESULTS The lowest dose values found were 1.88 mGy for the eye lenses, 1.35 mGy for the parotid gland, 0.03 mGy for the thyroid gland and 0.1 mGy for the medulla oblongata using 2 mm collimation and 3 mm table feed at 25 mAs. Maximal dose values resulted using the 3/3 mm protocol at 200 mAs (31.00 mGy for the eye lense, 0.65 mGy for the thyroid gland). There were no significant differences found between the different CT scanners. CONCLUSIONS Using up-to-date CT scanners, radiation exposure may be reduced by a factor of 15-20 compared to that of conventional CT technique. Thus, the exposure of the eye lens comes to only a thousandth of the value supposedly inducing a cataract, as published by the ICRP.

UI MeSH Term Description Entries
D007908 Lens, Crystalline A transparent, biconvex structure of the EYE, enclosed in a capsule and situated behind the IRIS and in front of the vitreous humor (VITREOUS BODY). It is slightly overlapped at its margin by the ciliary processes. Adaptation by the CILIARY BODY is crucial for OCULAR ACCOMMODATION. Eye Lens,Lens, Eye,Crystalline Lens
D008526 Medulla Oblongata The lower portion of the BRAIN STEM. It is inferior to the PONS and anterior to the CEREBELLUM. Medulla oblongata serves as a relay station between the brain and the spinal cord, and contains centers for regulating respiratory, vasomotor, cardiac, and reflex activities. Accessory Cuneate Nucleus,Ambiguous Nucleus,Arcuate Nucleus of the Medulla,Arcuate Nucleus-1,External Cuneate Nucleus,Lateral Cuneate Nucleus,Nucleus Ambiguus,Ambiguus, Nucleus,Arcuate Nucleus 1,Arcuate Nucleus-1s,Cuneate Nucleus, Accessory,Cuneate Nucleus, External,Cuneate Nucleus, Lateral,Medulla Oblongatas,Nucleus, Accessory Cuneate,Nucleus, Ambiguous,Nucleus, External Cuneate,Nucleus, Lateral Cuneate
D010256 Paranasal Sinuses Air-filled spaces located within the bones around the NASAL CAVITY. They are extensions of the nasal cavity and lined by the ciliated NASAL MUCOSA. Each sinus is named for the cranial bone in which it is located, such as the ETHMOID SINUS; the FRONTAL SINUS; the MAXILLARY SINUS; and the SPHENOID SINUS. Nasal Sinuses,Osteomeatal Complex,Ostiomeatal Complex,Ostiomeatal Unit,Sinonasal Tract,Supraorbital Ethmoid Cell,Cell, Supraorbital Ethmoid,Complex, Osteomeatal,Ethmoid Cell, Supraorbital,Osteomeatal Complices,Ostiomeatal Complices,Ostiomeatal Units,Sinonasal Tracts,Sinuses, Nasal,Supraorbital Ethmoid Cells,Tract, Sinonasal
D010306 Parotid Gland The largest of the three pairs of SALIVARY GLANDS. They lie on the sides of the FACE immediately below and in front of the EAR. Gland, Parotid,Glands, Parotid,Parotid Glands
D011829 Radiation Dosage The amount of radiation energy that is deposited in a unit mass of material, such as tissues of plants or animal. In RADIOTHERAPY, radiation dosage is expressed in gray units (Gy). In RADIOLOGIC HEALTH, the dosage is expressed by the product of absorbed dose (Gy) and quality factor (a function of linear energy transfer), and is called radiation dose equivalent in sievert units (Sv). Sievert Units,Dosage, Radiation,Gray Units,Gy Radiation,Sv Radiation Dose Equivalent,Dosages, Radiation,Radiation Dosages,Units, Gray,Units, Sievert
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D013819 Thermoluminescent Dosimetry The use of a device composed of thermoluminescent material for measuring exposure to IONIZING RADIATION. The thermoluminescent material emits light when heated. The amount of light emitted is proportional to the amount of ionizing radiation to which the material has been exposed. Dosimetries, Thermoluminescent,Dosimetry, Thermoluminescent,Thermoluminescent Dosimetries
D013961 Thyroid Gland A highly vascularized endocrine gland consisting of two lobes joined by a thin band of tissue with one lobe on each side of the TRACHEA. It secretes THYROID HORMONES from the follicular cells and CALCITONIN from the parafollicular cells thereby regulating METABOLISM and CALCIUM level in blood, respectively. Thyroid,Gland, Thyroid,Glands, Thyroid,Thyroid Glands,Thyroids
D014057 Tomography, X-Ray Computed Tomography using x-ray transmission and a computer algorithm to reconstruct the image. CAT Scan, X-Ray,CT Scan, X-Ray,Cine-CT,Computerized Tomography, X-Ray,Electron Beam Computed Tomography,Tomodensitometry,Tomography, Transmission Computed,X-Ray Tomography, Computed,CAT Scan, X Ray,CT X Ray,Computed Tomography, X-Ray,Computed X Ray Tomography,Computerized Tomography, X Ray,Electron Beam Tomography,Tomography, X Ray Computed,Tomography, X-Ray Computer Assisted,Tomography, X-Ray Computerized,Tomography, X-Ray Computerized Axial,Tomography, Xray Computed,X Ray Computerized Tomography,X Ray Tomography, Computed,X-Ray Computer Assisted Tomography,X-Ray Computerized Axial Tomography,Beam Tomography, Electron,CAT Scans, X-Ray,CT Scan, X Ray,CT Scans, X-Ray,CT X Rays,Cine CT,Computed Tomography, Transmission,Computed Tomography, X Ray,Computed Tomography, Xray,Computed X-Ray Tomography,Scan, X-Ray CAT,Scan, X-Ray CT,Scans, X-Ray CAT,Scans, X-Ray CT,Tomographies, Computed X-Ray,Tomography, Computed X-Ray,Tomography, Electron Beam,Tomography, X Ray Computer Assisted,Tomography, X Ray Computerized,Tomography, X Ray Computerized Axial,Transmission Computed Tomography,X Ray Computer Assisted Tomography,X Ray Computerized Axial Tomography,X Ray, CT,X Rays, CT,X-Ray CAT Scan,X-Ray CAT Scans,X-Ray CT Scan,X-Ray CT Scans,X-Ray Computed Tomography,X-Ray Computerized Tomography,Xray Computed Tomography
D019047 Phantoms, Imaging Devices or objects in various imaging techniques used to visualize or enhance visualization by simulating conditions encountered in the procedure. Phantoms are used very often in procedures employing or measuring x-irradiation or radioactive material to evaluate performance. Phantoms often have properties similar to human tissue. Water demonstrates absorbing properties similar to normal tissue, hence water-filled phantoms are used to map radiation levels. Phantoms are used also as teaching aids to simulate real conditions with x-ray or ultrasonic machines. (From Iturralde, Dictionary and Handbook of Nuclear Medicine and Clinical Imaging, 1990) Phantoms, Radiographic,Phantoms, Radiologic,Radiographic Phantoms,Radiologic Phantoms,Phantom, Radiographic,Phantom, Radiologic,Radiographic Phantom,Radiologic Phantom,Imaging Phantom,Imaging Phantoms,Phantom, Imaging

Related Publications

F Dammann, and E Momino-Traserra, and C Remy, and P L Pereira, and I Baumann, and A Koitschev, and C D Claussen
April 1995, AJNR. American journal of neuroradiology,
F Dammann, and E Momino-Traserra, and C Remy, and P L Pereira, and I Baumann, and A Koitschev, and C D Claussen
October 1976, Medizinische Klinik,
F Dammann, and E Momino-Traserra, and C Remy, and P L Pereira, and I Baumann, and A Koitschev, and C D Claussen
August 2000, RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin,
F Dammann, and E Momino-Traserra, and C Remy, and P L Pereira, and I Baumann, and A Koitschev, and C D Claussen
January 1985, Neuroradiology,
F Dammann, and E Momino-Traserra, and C Remy, and P L Pereira, and I Baumann, and A Koitschev, and C D Claussen
May 1996, Neuroradiology,
F Dammann, and E Momino-Traserra, and C Remy, and P L Pereira, and I Baumann, and A Koitschev, and C D Claussen
December 1991, Radiology,
F Dammann, and E Momino-Traserra, and C Remy, and P L Pereira, and I Baumann, and A Koitschev, and C D Claussen
March 1994, Aktuelle Radiologie,
F Dammann, and E Momino-Traserra, and C Remy, and P L Pereira, and I Baumann, and A Koitschev, and C D Claussen
March 1984, Radiologic clinics of North America,
F Dammann, and E Momino-Traserra, and C Remy, and P L Pereira, and I Baumann, and A Koitschev, and C D Claussen
June 2020, Biomedical physics & engineering express,
F Dammann, and E Momino-Traserra, and C Remy, and P L Pereira, and I Baumann, and A Koitschev, and C D Claussen
January 1991, The Journal of laryngology and otology,
Copied contents to your clipboard!