Determination of cadmium by differential pulse adsorptive stripping voltammetry. 2000

P Suciu, and M Vega, and L Roman
Department of Analytical Chemistry, University of Medicine and Pharmacy Iuliu Hatieganu, Cluj-Napoca, Romania. psuciu@umfcluj.ro

A study of the adsorptive stripping voltammetry of cadmium on a mercury drop electrode is reported in which 2-mercapto-5-phenyl-amino-1,3,4-thiadiazole (MPATD), synthesized at home has been used as a chelating agent. The most suitable operating conditions and parameters such as buffer, pH, deposition potential, deposition time, ligand concentration, scan rate and others were selected and the determination of cadmium from aqueous solutions using the standard additions method was possible. As validation criteria, the linearity and range, repeatability of the signal, repeatability of the concentration and accuracy were investigated. A limit of detection of 4.67 x 10(-10) M and a limit of quantification of 1.55 x 10(-9) M were achieved. The interference of other metals and organic substances was studied. Concerning a possible catalytic effect, no one was found. The method was designed in order to determine Cd from biological samples.

UI MeSH Term Description Entries
D002104 Cadmium An element with atomic symbol Cd, atomic number 48, and atomic weight 112.41. It is a metal and ingestion will lead to CADMIUM POISONING.
D002614 Chelating Agents Chemicals that bind to and remove ions from solutions. Many chelating agents function through the formation of COORDINATION COMPLEXES with METALS. Chelating Agent,Chelator,Complexons,Metal Antagonists,Chelators,Metal Chelating Agents,Agent, Chelating,Agents, Chelating,Agents, Metal Chelating,Antagonists, Metal,Chelating Agents, Metal
D004563 Electrochemistry The study of chemical changes resulting from electrical action and electrical activity resulting from chemical changes. Electrochemistries
D004566 Electrodes Electric conductors through which electric currents enter or leave a medium, whether it be an electrolytic solution, solid, molten mass, gas, or vacuum. Anode,Anode Materials,Cathode,Cathode Materials,Anode Material,Anodes,Cathode Material,Cathodes,Electrode,Material, Anode,Material, Cathode
D012680 Sensitivity and Specificity Binary classification measures to assess test results. Sensitivity or recall rate is the proportion of true positives. Specificity is the probability of correctly determining the absence of a condition. (From Last, Dictionary of Epidemiology, 2d ed) Specificity,Sensitivity,Specificity and Sensitivity
D013830 Thiadiazoles Heterocyclic compounds composed of a five-membered heterocyclic ring which contains one sulfur and two nitrogen atoms. Thiadiazole
D015203 Reproducibility of Results The statistical reproducibility of measurements (often in a clinical context), including the testing of instrumentation or techniques to obtain reproducible results. The concept includes reproducibility of physiological measurements, which may be used to develop rules to assess probability or prognosis, or response to a stimulus; reproducibility of occurrence of a condition; and reproducibility of experimental results. Reliability and Validity,Reliability of Result,Reproducibility Of Result,Reproducibility of Finding,Validity of Result,Validity of Results,Face Validity,Reliability (Epidemiology),Reliability of Results,Reproducibility of Findings,Test-Retest Reliability,Validity (Epidemiology),Finding Reproducibilities,Finding Reproducibility,Of Result, Reproducibility,Of Results, Reproducibility,Reliabilities, Test-Retest,Reliability, Test-Retest,Result Reliabilities,Result Reliability,Result Validities,Result Validity,Result, Reproducibility Of,Results, Reproducibility Of,Test Retest Reliability,Validity and Reliability,Validity, Face

Related Publications

P Suciu, and M Vega, and L Roman
March 2003, Journal of pharmaceutical and biomedical analysis,
P Suciu, and M Vega, and L Roman
August 2009, Journal of hazardous materials,
P Suciu, and M Vega, and L Roman
May 2002, Bioelectrochemistry (Amsterdam, Netherlands),
P Suciu, and M Vega, and L Roman
February 2004, Talanta,
Copied contents to your clipboard!