High-performance liquid chromatographic determination of tianeptine in plasma applied to pharmacokinetic studies. 2000

J M Gaulier, and P Marquet, and E Lacassie, and R Desroches, and G Lachatre
Department of Pharmacology and Toxicology, University Hospital, Limoges, France.

An improved analytical method for the quantitative measurement of tianeptine and its main metabolite MC5 in human plasma was designed. Extraction involved ion-paired liquid-liquid extraction of the compounds from 1.0 ml of human plasma adjusted to pH 7.0. HPLC separation was performed using a Nucleosil C18, 5 microm column (150x4.6 mm I.D.) and a mixture of acetonitrile and pH 3, 2.7 g l(-1) solution of sodium heptanesulfonate in distilled water (40:60, v/v) as mobile phase. UV detection was performed using a diode array detector in the 200-400 nm passband, and quantification of the analytes was made at 220 nm. For both tianeptine and MC5 metabolite, the limit of quantitation was 5 microg l(-1) and the calibration curves were linear from 5 to 500 microg l(-1). Intra- and inter-assay precision and accuracy fulfilled the international requirements. The recovery of tianeptine and its metabolite from plasma was, respectively, 71.5 and 74.3% at 20 microg l(-1), 71.2 and 70.8% at 400 microg l(-1). The selectivity of the method was checked by verifying the absence of chromatographic interference from pure solutions of the most commonly associated therapeutic drugs. This method, validated according to the criteria established by the Journal of Chromatography B, was applied to the determination of tianeptine and MC5-metabolite in human plasma in pharmacokinetic studies.

UI MeSH Term Description Entries
D012015 Reference Standards A basis of value established for the measure of quantity, weight, extent or quality, e.g. weight standards, standard solutions, methods, techniques, and procedures used in diagnosis and therapy. Standard Preparations,Standards, Reference,Preparations, Standard,Standardization,Standards,Preparation, Standard,Reference Standard,Standard Preparation,Standard, Reference
D002138 Calibration Determination, by measurement or comparison with a standard, of the correct value of each scale reading on a meter or other measuring instrument; or determination of the settings of a control device that correspond to particular values of voltage, current, frequency or other output. Calibrations
D002851 Chromatography, High Pressure Liquid Liquid chromatographic techniques which feature high inlet pressures, high sensitivity, and high speed. Chromatography, High Performance Liquid,Chromatography, High Speed Liquid,Chromatography, Liquid, High Pressure,HPLC,High Performance Liquid Chromatography,High-Performance Liquid Chromatography,UPLC,Ultra Performance Liquid Chromatography,Chromatography, High-Performance Liquid,High-Performance Liquid Chromatographies,Liquid Chromatography, High-Performance
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D000929 Antidepressive Agents, Tricyclic Substances that contain a fused three-ring moiety and are used in the treatment of depression. These drugs block the uptake of norepinephrine and serotonin into axon terminals and may block some subtypes of serotonin, adrenergic, and histamine receptors. However, the mechanism of their antidepressant effects is not clear because the therapeutic effects usually take weeks to develop and may reflect compensatory changes in the central nervous system. Antidepressants, Tricyclic,Tricyclic Antidepressant,Tricyclic Antidepressant Drug,Tricyclic Antidepressive Agent,Tricyclic Antidepressive Agents,Antidepressant Drugs, Tricyclic,Agent, Tricyclic Antidepressive,Agents, Tricyclic Antidepressive,Antidepressant Drug, Tricyclic,Antidepressant, Tricyclic,Antidepressive Agent, Tricyclic,Drug, Tricyclic Antidepressant,Drugs, Tricyclic Antidepressant,Tricyclic Antidepressant Drugs,Tricyclic Antidepressants
D012680 Sensitivity and Specificity Binary classification measures to assess test results. Sensitivity or recall rate is the proportion of true positives. Specificity is the probability of correctly determining the absence of a condition. (From Last, Dictionary of Epidemiology, 2d ed) Specificity,Sensitivity,Specificity and Sensitivity
D013056 Spectrophotometry, Ultraviolet Determination of the spectra of ultraviolet absorption by specific molecules in gases or liquids, for example Cl2, SO2, NO2, CS2, ozone, mercury vapor, and various unsaturated compounds. (McGraw-Hill Dictionary of Scientific and Technical Terms, 4th ed) Ultraviolet Spectrophotometry
D013841 Thiazepines Compounds that are derivatives of THIEPINS, with a nitrogen replacing a carbon in the seven-membered heterocyclic compound. Thiazepine
D015203 Reproducibility of Results The statistical reproducibility of measurements (often in a clinical context), including the testing of instrumentation or techniques to obtain reproducible results. The concept includes reproducibility of physiological measurements, which may be used to develop rules to assess probability or prognosis, or response to a stimulus; reproducibility of occurrence of a condition; and reproducibility of experimental results. Reliability and Validity,Reliability of Result,Reproducibility Of Result,Reproducibility of Finding,Validity of Result,Validity of Results,Face Validity,Reliability (Epidemiology),Reliability of Results,Reproducibility of Findings,Test-Retest Reliability,Validity (Epidemiology),Finding Reproducibilities,Finding Reproducibility,Of Result, Reproducibility,Of Results, Reproducibility,Reliabilities, Test-Retest,Reliability, Test-Retest,Result Reliabilities,Result Reliability,Result Validities,Result Validity,Result, Reproducibility Of,Results, Reproducibility Of,Test Retest Reliability,Validity and Reliability,Validity, Face

Related Publications

J M Gaulier, and P Marquet, and E Lacassie, and R Desroches, and G Lachatre
June 1995, Journal of chromatography. B, Biomedical applications,
J M Gaulier, and P Marquet, and E Lacassie, and R Desroches, and G Lachatre
November 1981, Journal of chromatography,
J M Gaulier, and P Marquet, and E Lacassie, and R Desroches, and G Lachatre
January 2010, Iranian journal of pharmaceutical research : IJPR,
J M Gaulier, and P Marquet, and E Lacassie, and R Desroches, and G Lachatre
June 1988, Journal of chromatography,
J M Gaulier, and P Marquet, and E Lacassie, and R Desroches, and G Lachatre
October 2008, Biomedical chromatography : BMC,
J M Gaulier, and P Marquet, and E Lacassie, and R Desroches, and G Lachatre
December 1991, Journal of chromatography,
J M Gaulier, and P Marquet, and E Lacassie, and R Desroches, and G Lachatre
May 1984, Journal of chromatography,
J M Gaulier, and P Marquet, and E Lacassie, and R Desroches, and G Lachatre
March 1988, Journal of chromatography,
J M Gaulier, and P Marquet, and E Lacassie, and R Desroches, and G Lachatre
November 1998, Journal of chromatography. B, Biomedical sciences and applications,
J M Gaulier, and P Marquet, and E Lacassie, and R Desroches, and G Lachatre
October 2003, Journal of pharmaceutical and biomedical analysis,
Copied contents to your clipboard!