[Diagnosis of renal artery stenosis with magnetic resonance angiography and stenosis quantification]. 2000

B Marchand, and M Hernandez-Hoyos, and M Orkisz, and P Douek
Service de radiologie, Hôpital de la Croix-Rousse, 103 Grande rue de la Croix-Rousse, 69317 Lyon Cedex 04.

Atherosclerotic disease is the most common pathologic condition of renal artery stenosis, which typically compromises the ostium or the proximal 1-2 cm of renal arteries and is also usually present in the abdominal aorta. Fibromuscular dysplasia is the second most common cause of renal artery stenosis (RAS) which usually involves the distal two-third of the main renal artery with bed-like stenosis alternating with small fusiform or saccular aneurysms. Magnetic Resonance Angiography (MRA) was initially performed without contrast media injection using two- or three-dimensional Time-of-Flight (TOF) or Phase-Contrast (PC) techniques. Sensitivity and specificity of non-enhanced MRA in detection of proximal RAS are comprised between 53%-100% and 47%-97% respectively (table I). Main limitations of non-enhanced MRA are the long acquisition time, i.e. 5-8 min, the short field of view with lack of kidney visualization and major artifacts. Recent improvements allowed a three-dimensional acquisition during a single breath-hold (18-23 sec), associated to a bolus injection of a gadolinium chelate demonstrating a lack of nephrotoxicity. 3D gadolinium-enhanced ultrafast gradient-echo MRA techniques (3D enhanced-MRA) requires a precise technique. Firstly, kidney localization and morphologic imaging is performed before a 3D MRA data acquisition without injection (fig. 1). Secondly two successive 3D MRA sequences are performed synchronized with the gadolinium chelate bolus injection: the first acquisition corresponds to the arterial enhancement (fig. 4) and the second one to the venous enhancement. At last, a three-dimensional phase contrast could also be performed. After data acquisition, image post-processing is performed including image subtraction, maximum intensity projection (MIP) and reformation images of each renal artery, the abdominal aorta and its main branches (fig. 2, 3). The normal findings, pitfalls and anatomic variation are explained in detail. Particularly, when 3D enhanced MR angiography shows a normal artery, it is considered to be normal. It is also important to be aware of the existence of accessory or aberrant renal arteries that are well diagnosed by 3D enhanced MRA in 75% to 100% of the cases (fig. 2). 3D enhanced-MR angiography present several advantages in comparison to nonenhanced MRA: 1) a great field-of-view (30-36 cm) could be used allowing visualization of the abdominal aorta as well as its main branches; 2) the fast acquisition time allows an arterial imaging followed by a venous enhancement; 3) the kidneys are analyzed: kidney length, cortical thickness, corticomedullary differentiation and renal enhancement are well evaluated; 4) an accurate sensitivity and specificity in detection of proximal RAS comprised between 88%-100% and 71%-100% respectively (table II). Because a severe RAS (i.e. degree of stenosis > 50%) may cause renal ischemia leading to a blood pressure elevation that is often difficult to control with medical therapy, imaging has to assess the severity of RAS. MRA assessment of hemodynamic significance of RAS can be further refined by considering additional factors (fig. 4): arterial stop of signal, post stenotic dilatation, delayed renal enhancement and functional changes in the renal parenchyma (i.e. reduced kidney length and parenchymal thickness, loss of corticomedullary differentiation) (fig. 1). Precise evaluation of degree of stenosis requires the development of dedicated software such as MARACAS (MAgnetic Resonance Angiography Computer ASsisted analysis) software (fig. 5). In conclusions, 3D enhanced MRA allows an accurate diagnosis of proximal RAS, mainly due to atherosclerosis, without the risks associated with nephrotoxic contrast agents, ionizing radiation or arterial catheterization.

UI MeSH Term Description Entries
D007091 Image Processing, Computer-Assisted A technique of inputting two-dimensional or three-dimensional images into a computer and then enhancing or analyzing the imagery into a form that is more useful to the human observer. Biomedical Image Processing,Computer-Assisted Image Processing,Digital Image Processing,Image Analysis, Computer-Assisted,Image Reconstruction,Medical Image Processing,Analysis, Computer-Assisted Image,Computer-Assisted Image Analysis,Computer Assisted Image Analysis,Computer Assisted Image Processing,Computer-Assisted Image Analyses,Image Analyses, Computer-Assisted,Image Analysis, Computer Assisted,Image Processing, Biomedical,Image Processing, Computer Assisted,Image Processing, Digital,Image Processing, Medical,Image Processings, Medical,Image Reconstructions,Medical Image Processings,Processing, Biomedical Image,Processing, Digital Image,Processing, Medical Image,Processings, Digital Image,Processings, Medical Image,Reconstruction, Image,Reconstructions, Image
D012078 Renal Artery Obstruction Narrowing or occlusion of the RENAL ARTERY or arteries. It is due usually to ATHEROSCLEROSIS; FIBROMUSCULAR DYSPLASIA; THROMBOSIS; EMBOLISM, or external pressure. The reduced renal perfusion can lead to renovascular hypertension (HYPERTENSION, RENOVASCULAR). Renal Artery Stenosis,Obstruction, Renal Artery,Obstructions, Renal Artery,Renal Artery Obstructions,Renal Artery Stenoses,Stenoses, Renal Artery,Stenosis, Renal Artery
D003287 Contrast Media Substances used to allow enhanced visualization of tissues. Radiopaque Media,Contrast Agent,Contrast Agents,Contrast Material,Contrast Materials,Radiocontrast Agent,Radiocontrast Agents,Radiocontrast Media,Agent, Contrast,Agent, Radiocontrast,Agents, Contrast,Agents, Radiocontrast,Material, Contrast,Materials, Contrast,Media, Contrast,Media, Radiocontrast,Media, Radiopaque
D005352 Fibromuscular Dysplasia An idiopathic, segmental, nonatheromatous disease of the musculature of arterial walls, leading to STENOSIS of small and medium-sized arteries. There is true proliferation of SMOOTH MUSCLE CELLS and fibrous tissue. Fibromuscular dysplasia lesions are smooth stenosis and occur most often in the renal and carotid arteries. They may also occur in other peripheral arteries of the extremity. Fibromuscular Dysplasia of Arteries,Arteries Fibromuscular Dysplasia,Arteries Fibromuscular Dysplasias,Dysplasia, Fibromuscular,Fibromuscular Dysplasias
D005682 Gadolinium An element of the rare earth family of metals. It has the atomic symbol Gd, atomic number 64, and atomic weight 157.25. Its oxide is used in the control rods of some nuclear reactors.
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D001161 Arteriosclerosis Thickening and loss of elasticity of the walls of ARTERIES of all sizes. There are many forms classified by the types of lesions and arteries involved, such as ATHEROSCLEROSIS with fatty lesions in the ARTERIAL INTIMA of medium and large muscular arteries. Arterioscleroses
D012984 Software Sequential operating programs and data which instruct the functioning of a digital computer. Computer Programs,Computer Software,Open Source Software,Software Engineering,Software Tools,Computer Applications Software,Computer Programs and Programming,Computer Software Applications,Application, Computer Software,Applications Software, Computer,Applications Softwares, Computer,Applications, Computer Software,Computer Applications Softwares,Computer Program,Computer Software Application,Engineering, Software,Open Source Softwares,Program, Computer,Programs, Computer,Software Application, Computer,Software Applications, Computer,Software Tool,Software, Computer,Software, Computer Applications,Software, Open Source,Softwares, Computer Applications,Softwares, Open Source,Source Software, Open,Source Softwares, Open,Tool, Software,Tools, Software
D018810 Magnetic Resonance Angiography Non-invasive method of vascular imaging and determination of internal anatomy without injection of contrast media or radiation exposure. The technique is used especially in CEREBRAL ANGIOGRAPHY as well as for studies of other vascular structures. Angiography, Magnetic Resonance,MRI Angiography,Perfusion Magnetic Resonance Imaging,Perfusion Weighted MRI,Angiographies, MRI,Angiographies, Magnetic Resonance,Angiography, MRI,MRI Angiographies,MRI, Perfusion Weighted,Magnetic Resonance Angiographies
D021621 Imaging, Three-Dimensional The process of generating three-dimensional images by electronic, photographic, or other methods. For example, three-dimensional images can be generated by assembling multiple tomographic images with the aid of a computer, while photographic 3-D images (HOLOGRAPHY) can be made by exposing film to the interference pattern created when two laser light sources shine on an object. Computer-Assisted Three-Dimensional Imaging,Imaging, Three-Dimensional, Computer Assisted,3-D Image,3-D Imaging,Computer-Generated 3D Imaging,Three-Dimensional Image,Three-Dimensional Imaging, Computer Generated,3 D Image,3 D Imaging,3-D Images,3-D Imagings,3D Imaging, Computer-Generated,3D Imagings, Computer-Generated,Computer Assisted Three Dimensional Imaging,Computer Generated 3D Imaging,Computer-Assisted Three-Dimensional Imagings,Computer-Generated 3D Imagings,Image, 3-D,Image, Three-Dimensional,Images, 3-D,Images, Three-Dimensional,Imaging, 3-D,Imaging, Computer-Assisted Three-Dimensional,Imaging, Computer-Generated 3D,Imaging, Three Dimensional,Imagings, 3-D,Imagings, Computer-Assisted Three-Dimensional,Imagings, Computer-Generated 3D,Imagings, Three-Dimensional,Three Dimensional Image,Three Dimensional Imaging, Computer Generated,Three-Dimensional Images,Three-Dimensional Imaging,Three-Dimensional Imaging, Computer-Assisted,Three-Dimensional Imagings,Three-Dimensional Imagings, Computer-Assisted

Related Publications

B Marchand, and M Hernandez-Hoyos, and M Orkisz, and P Douek
July 2003, Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association,
B Marchand, and M Hernandez-Hoyos, and M Orkisz, and P Douek
December 1993, Journal of hypertension. Supplement : official journal of the International Society of Hypertension,
B Marchand, and M Hernandez-Hoyos, and M Orkisz, and P Douek
March 2003, Clinical radiology,
B Marchand, and M Hernandez-Hoyos, and M Orkisz, and P Douek
July 1995, Clinical radiology,
B Marchand, and M Hernandez-Hoyos, and M Orkisz, and P Douek
October 1994, American journal of kidney diseases : the official journal of the National Kidney Foundation,
B Marchand, and M Hernandez-Hoyos, and M Orkisz, and P Douek
December 2003, American journal of hypertension,
B Marchand, and M Hernandez-Hoyos, and M Orkisz, and P Douek
August 1994, American journal of surgery,
B Marchand, and M Hernandez-Hoyos, and M Orkisz, and P Douek
July 2002, Clinical radiology,
Copied contents to your clipboard!