End-tidal to arterial oxygen tension difference as an oxygenation index. 2001

J Bengtsson, and B Bake, and A Johansson, and J P Bengtson
Department of Paediatric Anaesthesia and Intensive Care, The Queen Silvia Children's Hospital, Göteborg University, Sweden.

BACKGROUND "Ideal" alveolar oxygen tension (PAO2) is a calculated entity and the alveolar-arterial oxygen tension difference (PA-aO2) is used to evaluate gas exchange function of the lungs. Accurate calculations of PAO2 necessitate measurements of the respiratory exchange ratio (RER), which is less frequently done, and most often approximations are made. The measured end-tidal oxygen tension (PETO2) is a reflection of the alveolar oxygen tension. The aim was to study the relationship between PAO2 and PETO2, and to see whether the end-tidal to arterial oxygen tension difference (PET-aO2) could give the same information about lung function as PA-aO2. METHODS Twenty patients admitted for cardio-pulmonary exercise tests were studied. They bicycled for 4 min at each work load until maximum work load was reached. Arterial blood gases were analysed before, after 4 min at each work load, at maximum work load and after 2 min of recovery. A metabolic computer measured mixed expired gas concentrations. End-tidal gas concentrations were measured with a side stream gas analyser. RESULTS We measured major increases in oxygen uptake, carbon dioxide elimination and RER. PAO2 and PETO2 increased at maximum exercise and during recovery. PAO2 and PETO2 were closely correlated during the study, through great changes in oxygen uptake and RER (r=0.88). When correction was made for wet gas the median difference was 0.12 kPa. CONCLUSIONS At ambient air (FIO2=0.21), PET-aO2 as a respiratory index may give equivalent information to PA-aO2, without the need for measurements of mixed expired gas tensions or the hazard of an assumed RER.

UI MeSH Term Description Entries
D008168 Lung Either of the pair of organs occupying the cavity of the thorax that effect the aeration of the blood. Lungs
D008297 Male Males
D008875 Middle Aged An adult aged 45 - 64 years. Middle Age
D010100 Oxygen An element with atomic symbol O, atomic number 8, and atomic weight [15.99903; 15.99977]. It is the most abundant element on earth and essential for respiration. Dioxygen,Oxygen-16,Oxygen 16
D010101 Oxygen Consumption The rate at which oxygen is used by a tissue; microliters of oxygen STPD used per milligram of tissue per hour; the rate at which oxygen enters the blood from alveolar gas, equal in the steady state to the consumption of oxygen by tissue metabolism throughout the body. (Stedman, 25th ed, p346) Consumption, Oxygen,Consumptions, Oxygen,Oxygen Consumptions
D011650 Pulmonary Alveoli Small polyhedral outpouchings along the walls of the alveolar sacs, alveolar ducts and terminal bronchioles through the walls of which gas exchange between alveolar air and pulmonary capillary blood takes place. Alveoli, Pulmonary,Alveolus, Pulmonary,Pulmonary Alveolus
D002245 Carbon Dioxide A colorless, odorless gas that can be formed by the body and is necessary for the respiration cycle of plants and animals. Carbonic Anhydride,Anhydride, Carbonic,Dioxide, Carbon
D005080 Exercise Test Controlled physical activity which is performed in order to allow assessment of physiological functions, particularly cardiovascular and pulmonary, but also aerobic capacity. Maximal (most intense) exercise is usually required but submaximal exercise is also used. Arm Ergometry Test,Bicycle Ergometry Test,Cardiopulmonary Exercise Testing,Exercise Testing,Step Test,Stress Test,Treadmill Test,Cardiopulmonary Exercise Test,EuroFit Tests,Eurofit Test Battery,European Fitness Testing Battery,Fitness Testing,Physical Fitness Testing,Arm Ergometry Tests,Bicycle Ergometry Tests,Cardiopulmonary Exercise Tests,Ergometry Test, Arm,Ergometry Test, Bicycle,Ergometry Tests, Arm,Ergometry Tests, Bicycle,EuroFit Test,Eurofit Test Batteries,Exercise Test, Cardiopulmonary,Exercise Testing, Cardiopulmonary,Exercise Tests,Exercise Tests, Cardiopulmonary,Fitness Testing, Physical,Fitness Testings,Step Tests,Stress Tests,Test Battery, Eurofit,Test, Arm Ergometry,Test, Bicycle Ergometry,Test, Cardiopulmonary Exercise,Test, EuroFit,Test, Exercise,Test, Step,Test, Stress,Test, Treadmill,Testing, Cardiopulmonary Exercise,Testing, Exercise,Testing, Fitness,Testing, Physical Fitness,Tests, Arm Ergometry,Tests, Bicycle Ergometry,Tests, Cardiopulmonary Exercise,Tests, EuroFit,Tests, Exercise,Tests, Step,Tests, Stress,Tests, Treadmill,Treadmill Tests
D005260 Female Females
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man

Related Publications

J Bengtsson, and B Bake, and A Johansson, and J P Bengtson
July 1993, Critical care medicine,
J Bengtsson, and B Bake, and A Johansson, and J P Bengtson
July 1986, Anaesthesia,
J Bengtsson, and B Bake, and A Johansson, and J P Bengtson
August 2006, Masui. The Japanese journal of anesthesiology,
J Bengtsson, and B Bake, and A Johansson, and J P Bengtson
December 1992, British journal of anaesthesia,
J Bengtsson, and B Bake, and A Johansson, and J P Bengtson
February 1987, Anaesthesia,
J Bengtsson, and B Bake, and A Johansson, and J P Bengtson
March 1989, Canadian journal of anaesthesia = Journal canadien d'anesthesie,
J Bengtsson, and B Bake, and A Johansson, and J P Bengtson
January 1982, Canadian Anaesthetists' Society journal,
J Bengtsson, and B Bake, and A Johansson, and J P Bengtson
May 1987, Anaesthesia,
J Bengtsson, and B Bake, and A Johansson, and J P Bengtson
December 1987, Anaesthesia,
J Bengtsson, and B Bake, and A Johansson, and J P Bengtson
March 2001, British journal of anaesthesia,
Copied contents to your clipboard!