Image quality and dose in film-screen magnification mammography. 2000

B J McParland
Department of Medical Imaging-1528, King Fahad National Guard Hospital, PO Box 22490, Riyadh, Saudi Arabia 11426.

Extended exposure times in magnification mammography are a result of the reduced X-ray tube currents required for a small focal spot. The consequences of this are the potential for reduced image quality through motion blur during exposure as well as the onset of film reciprocity law failure. Previous investigators have suggested increasing the X-ray tube potential as a practical mechanism for reducing exposure times in magnification mammography and have demonstrated negligible image quality degradation at least up to 32 kVp. This paper describes a film-screen magnification mammography study that expands upon this previous work to investigate the magnitude of the reduction of breast mean glandular dose and exposure time and the changes in subjective image quality (visibility of low contrast details in an RMI 152 phantom) with increases in tube potential between 28 kVp and 35 kVp. Measures of changes in the radiographic contrast and in the scatter-to-primary ratio (SPR) in magnification geometry as a function of tube potential were also obtained. Evidence for reciprocity law failure was also assessed. For a constant film optical density, increasing the X-ray tube potential from 28 kVp to 35 kVp reduced the mean glandular dose from 3.9 mGy to 2.7 mGy and reduced the exposure time from 3.2 s to 1.0 s. Over this range, the detection rate of fibrils and microcalcification-mimicking specks did not vary with tube potential at the 0.05 level of significance. It was found that only the low contrast mass detail detection rate at 35 kVp was significantly less than that at 28 kVp. The measured radiographic contrast decreased with tube potential and the SPR increased with tube potential. However, both changes were weak, and linear regressions determined that the 95% confidence intervals of the slopes relating both contrast and SPR with tube potential encompassed zero. It is concluded that magnification mammography performed at 34 kVp yields significant reductions in exposure time and mean glandular dose, with a detail detection capability similar to that at 28 kVp.

UI MeSH Term Description Entries
D008327 Mammography Radiographic examination of the breast. 3D-Mammography,Digital Breast Tomosynthesis,Digital Mammography,X-ray Breast Tomosynthesis,3D Mammography,3D-Mammographies,Breast Tomosyntheses, Digital,Breast Tomosyntheses, X-ray,Breast Tomosynthesis, Digital,Breast Tomosynthesis, X-ray,Digital Breast Tomosyntheses,Digital Mammographies,Mammographies,Mammographies, Digital,Mammography, Digital,X ray Breast Tomosynthesis,X-ray Breast Tomosyntheses
D011829 Radiation Dosage The amount of radiation energy that is deposited in a unit mass of material, such as tissues of plants or animal. In RADIOTHERAPY, radiation dosage is expressed in gray units (Gy). In RADIOLOGIC HEALTH, the dosage is expressed by the product of absorbed dose (Gy) and quality factor (a function of linear energy transfer), and is called radiation dose equivalent in sievert units (Sv). Sievert Units,Dosage, Radiation,Gray Units,Gy Radiation,Sv Radiation Dose Equivalent,Dosages, Radiation,Radiation Dosages,Units, Gray,Units, Sievert
D011856 Radiographic Image Enhancement Improvement in the quality of an x-ray image by use of an intensifying screen, tube, or filter and by optimum exposure techniques. Digital processing methods are often employed. Digital Radiography,Image Enhancement, Radiographic,Radiography, Digital,Enhancement, Radiographic Image,Enhancements, Radiographic Image,Image Enhancements, Radiographic,Radiographic Image Enhancements
D001941 Breast Diseases Pathological processes of the BREAST. Endocrine Breast Diseases,Breast Disease,Breast Disease, Endocrine,Breast Diseases, Endocrine,Disease, Breast,Disease, Endocrine Breast,Diseases, Breast,Diseases, Endocrine Breast,Endocrine Breast Disease
D005260 Female Females
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D019047 Phantoms, Imaging Devices or objects in various imaging techniques used to visualize or enhance visualization by simulating conditions encountered in the procedure. Phantoms are used very often in procedures employing or measuring x-irradiation or radioactive material to evaluate performance. Phantoms often have properties similar to human tissue. Water demonstrates absorbing properties similar to normal tissue, hence water-filled phantoms are used to map radiation levels. Phantoms are used also as teaching aids to simulate real conditions with x-ray or ultrasonic machines. (From Iturralde, Dictionary and Handbook of Nuclear Medicine and Clinical Imaging, 1990) Phantoms, Radiographic,Phantoms, Radiologic,Radiographic Phantoms,Radiologic Phantoms,Phantom, Radiographic,Phantom, Radiologic,Radiographic Phantom,Radiologic Phantom,Imaging Phantom,Imaging Phantoms,Phantom, Imaging

Related Publications

Copied contents to your clipboard!