Mass spectrometric detection in narrow-bore (0.10 mm i.d.) capillary chromatography fast, sensitive and selective analysis of polychlorinated biphenyls. 2001

A Covaci, and P Schepens
Department of Pharmaceutical Sciences, Toxicological Center, University of Antwerp, Wilrijk, Belgium. covaci@uia.ua.ac.be

The combination of narrow-bore capillary gas chromatography with bench-top quadrupole mass spectrometric detection was evaluated for the determination of polychlorinated biphenyls (PCBs). The qualitative and quantitative performances of the system are illustrated by several analyses (PCB standards and human milk extracts). Capillary columns with different internal diameters (0.10, 0.18 and 0.22 mm, respectively) were compared for their ability to separate PCB congeners and the analysis time. Short run times (less than 7 min) were sufficient for complete separation of PCB congeners on a 0.10-mm internal diameter (I.D.) capillary column without any loss of resolution when compared with a 0.22 mm I.D. column. Good qualitative and quantitative data acquisition was possible with quadrupole mass spectrometer for run times of 8 min, but incomplete peak reading was observed when run times were reduced to 3-4 min. Selected ion monitoring and dwell times of 10 ms are necessary to obtain detection limits for individual PCB congeners as low as 0.4 pg microl(-1) for standard solutions and 0.2 ng g(-1) fat for milk extracts. By using cold splitless injection, relatively high volumes (1 microl) for narrow-bore capillaries could be injected without any peak distortion.

UI MeSH Term Description Entries
D008401 Gas Chromatography-Mass Spectrometry A microanalytical technique combining mass spectrometry and gas chromatography for the qualitative as well as quantitative determinations of compounds. Chromatography, Gas-Liquid-Mass Spectrometry,Chromatography, Gas-Mass Spectrometry,GCMS,Spectrometry, Mass-Gas Chromatography,Spectrum Analysis, Mass-Gas Chromatography,Gas-Liquid Chromatography-Mass Spectrometry,Mass Spectrometry-Gas Chromatography,Chromatography, Gas Liquid Mass Spectrometry,Chromatography, Gas Mass Spectrometry,Chromatography, Mass Spectrometry-Gas,Chromatography-Mass Spectrometry, Gas,Chromatography-Mass Spectrometry, Gas-Liquid,Gas Chromatography Mass Spectrometry,Gas Liquid Chromatography Mass Spectrometry,Mass Spectrometry Gas Chromatography,Spectrometries, Mass-Gas Chromatography,Spectrometry, Gas Chromatography-Mass,Spectrometry, Gas-Liquid Chromatography-Mass,Spectrometry, Mass Gas Chromatography,Spectrometry-Gas Chromatography, Mass,Spectrum Analysis, Mass Gas Chromatography
D008895 Milk, Human Milk that is produced by HUMAN MAMMARY GLANDS. Breast Milk,Human Milk,Milk, Breast
D011078 Polychlorinated Biphenyls Industrial products consisting of a mixture of chlorinated biphenyl congeners and isomers. These compounds are highly lipophilic and tend to accumulate in fat stores of animals. Many of these compounds are considered toxic and potential environmental pollutants. PCBs,Polychlorinated Biphenyl,Polychlorobiphenyl Compounds,Biphenyl, Polychlorinated,Biphenyls, Polychlorinated,Compounds, Polychlorobiphenyl
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D012680 Sensitivity and Specificity Binary classification measures to assess test results. Sensitivity or recall rate is the proportion of true positives. Specificity is the probability of correctly determining the absence of a condition. (From Last, Dictionary of Epidemiology, 2d ed) Specificity,Sensitivity,Specificity and Sensitivity
D013997 Time Factors Elements of limited time intervals, contributing to particular results or situations. Time Series,Factor, Time,Time Factor

Related Publications

A Covaci, and P Schepens
February 1998, Analytical chemistry,
A Covaci, and P Schepens
April 2009, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences,
Copied contents to your clipboard!