Rapid velocity-encoded cine imaging with turbo-BRISK. 1999

M Doyle, and E Kortright, and A S Anayiotos, and A M Elmahdi, and E G Walsh, and A R Fuisz, and G M Pohost
Department of Medicine, Division of Cardiovascular Disease, University of Alabama at Birmingham, Birmingham, Alabama, USA.

Velocity-encoded cine (VEC) imaging is potentially an important clinical diagnostic technique for cardiovascular diseases. Advances in gradient technology combined with segmentation approaches have made possible breathhold VEC imaging, allowing data to be obtained free of respiratory artifacts. However, when using conventional segmentation approaches, spatial and temporal resolutions are typically compromised to accommodate short breathhold times. Here we apply a sparse sampling technique, turbo-BRISK (i.e., segmented block regional interpolation scheme for k-space) to VEC imaging, allowing increased spatial and temporal resolution to be obtained in a short breathhold period. BRISK is a sparse sampling technique with interpolation used to generate unsampled data. BRISK was implemented to reduce the scan time by 70% compared with a conventional scan. Further, turbo-BRISK scans, using segmentation factors up to 5, reduce the scan time by up to 94%. Phantom and in vivo results are presented that demonstrate the accuracy of turbo-BRISK VEC imaging. In vitro validation is performed using conventional magnetic resonance VEC. Pulsatile centerline flow velocity measurements obtained with turbo-BRISK acquisitions were correlated with conventional magnetic resonance imaging measurements and achieved r values of 0.99 +/- 0.004 (mean +/- SD) with stroke volumes agreeing to within 4%. A potential limitation of BRISK is reduced accuracy for rapidly varying velocity profiles. We present low- and high-resolution data sets to illustrate the resolution dependence of this phenomenon and demonstrate that at conventional resolutions, turbo-BRISK can accurately represent rapid velocity changes. In vivo results indicate that centerline velocity waveforms in the descending aorta correlate well with conventional measurements with an average r value of 0.98 +/- 0.01.

UI MeSH Term Description Entries
D007091 Image Processing, Computer-Assisted A technique of inputting two-dimensional or three-dimensional images into a computer and then enhancing or analyzing the imagery into a form that is more useful to the human observer. Biomedical Image Processing,Computer-Assisted Image Processing,Digital Image Processing,Image Analysis, Computer-Assisted,Image Reconstruction,Medical Image Processing,Analysis, Computer-Assisted Image,Computer-Assisted Image Analysis,Computer Assisted Image Analysis,Computer Assisted Image Processing,Computer-Assisted Image Analyses,Image Analyses, Computer-Assisted,Image Analysis, Computer Assisted,Image Processing, Biomedical,Image Processing, Computer Assisted,Image Processing, Digital,Image Processing, Medical,Image Processings, Medical,Image Reconstructions,Medical Image Processings,Processing, Biomedical Image,Processing, Digital Image,Processing, Medical Image,Processings, Digital Image,Processings, Medical Image,Reconstruction, Image,Reconstructions, Image
D011673 Pulsatile Flow Rhythmic, intermittent propagation of a fluid through a BLOOD VESSEL or piping system, in contrast to constant, smooth propagation, which produces laminar flow. Flow, Pulsating,Perfusion, Pulsatile,Flow, Pulsatile,Flows, Pulsatile,Flows, Pulsating,Perfusions, Pulsatile,Pulsatile Flows,Pulsatile Perfusion,Pulsatile Perfusions,Pulsating Flow,Pulsating Flows
D012044 Regression Analysis Procedures for finding the mathematical function which best describes the relationship between a dependent variable and one or more independent variables. In linear regression (see LINEAR MODELS) the relationship is constrained to be a straight line and LEAST-SQUARES ANALYSIS is used to determine the best fit. In logistic regression (see LOGISTIC MODELS) the dependent variable is qualitative rather than continuously variable and LIKELIHOOD FUNCTIONS are used to find the best relationship. In multiple regression, the dependent variable is considered to depend on more than a single independent variable. Regression Diagnostics,Statistical Regression,Analysis, Regression,Analyses, Regression,Diagnostics, Regression,Regression Analyses,Regression, Statistical,Regressions, Statistical,Statistical Regressions
D001783 Blood Flow Velocity A value equal to the total volume flow divided by the cross-sectional area of the vascular bed. Blood Flow Velocities,Flow Velocities, Blood,Flow Velocity, Blood,Velocities, Blood Flow,Velocity, Blood Flow
D003326 Coronary Circulation The circulation of blood through the CORONARY VESSELS of the HEART. Circulation, Coronary
D006321 Heart The hollow, muscular organ that maintains the circulation of the blood. Hearts
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D012680 Sensitivity and Specificity Binary classification measures to assess test results. Sensitivity or recall rate is the proportion of true positives. Specificity is the probability of correctly determining the absence of a condition. (From Last, Dictionary of Epidemiology, 2d ed) Specificity,Sensitivity,Specificity and Sensitivity
D013318 Stroke Volume The amount of BLOOD pumped out of the HEART per beat, not to be confused with cardiac output (volume/time). It is calculated as the difference between the end-diastolic volume and the end-systolic volume. Ventricular Ejection Fraction,Ventricular End-Diastolic Volume,Ventricular End-Systolic Volume,Ejection Fraction, Ventricular,Ejection Fractions, Ventricular,End-Diastolic Volume, Ventricular,End-Diastolic Volumes, Ventricular,End-Systolic Volume, Ventricular,End-Systolic Volumes, Ventricular,Fraction, Ventricular Ejection,Fractions, Ventricular Ejection,Stroke Volumes,Ventricular Ejection Fractions,Ventricular End Diastolic Volume,Ventricular End Systolic Volume,Ventricular End-Diastolic Volumes,Ventricular End-Systolic Volumes,Volume, Stroke,Volume, Ventricular End-Diastolic,Volume, Ventricular End-Systolic,Volumes, Stroke,Volumes, Ventricular End-Diastolic,Volumes, Ventricular End-Systolic
D019028 Magnetic Resonance Imaging, Cine A type of imaging technique used primarily in the field of cardiology. By coordinating the fast gradient-echo MRI sequence with retrospective ECG-gating, numerous short time frames evenly spaced in the cardiac cycle are produced. These images are laced together in a cinematic display so that wall motion of the ventricles, valve motion, and blood flow patterns in the heart and great vessels can be visualized. Cine MRI,Cine Magnetic Resonance Imaging,Cine MRIs,MRI, Cine,MRIs, Cine

Related Publications

M Doyle, and E Kortright, and A S Anayiotos, and A M Elmahdi, and E G Walsh, and A R Fuisz, and G M Pohost
March 1997, Magnetic resonance in medicine,
M Doyle, and E Kortright, and A S Anayiotos, and A M Elmahdi, and E G Walsh, and A R Fuisz, and G M Pohost
February 1995, The American journal of cardiology,
M Doyle, and E Kortright, and A S Anayiotos, and A M Elmahdi, and E G Walsh, and A R Fuisz, and G M Pohost
November 2011, Magnetic resonance in medicine,
M Doyle, and E Kortright, and A S Anayiotos, and A M Elmahdi, and E G Walsh, and A R Fuisz, and G M Pohost
January 1993, Journal of magnetic resonance imaging : JMRI,
M Doyle, and E Kortright, and A S Anayiotos, and A M Elmahdi, and E G Walsh, and A R Fuisz, and G M Pohost
October 1992, Radiology,
M Doyle, and E Kortright, and A S Anayiotos, and A M Elmahdi, and E G Walsh, and A R Fuisz, and G M Pohost
March 1994, Journal of the American College of Cardiology,
M Doyle, and E Kortright, and A S Anayiotos, and A M Elmahdi, and E G Walsh, and A R Fuisz, and G M Pohost
June 1992, Radiology,
M Doyle, and E Kortright, and A S Anayiotos, and A M Elmahdi, and E G Walsh, and A R Fuisz, and G M Pohost
March 1996, Radiology,
M Doyle, and E Kortright, and A S Anayiotos, and A M Elmahdi, and E G Walsh, and A R Fuisz, and G M Pohost
November 1992, Journal of the American College of Cardiology,
M Doyle, and E Kortright, and A S Anayiotos, and A M Elmahdi, and E G Walsh, and A R Fuisz, and G M Pohost
January 1993, Journal of computer assisted tomography,
Copied contents to your clipboard!