Common faults in resuscitation equipment--guidelines for checking equipment and drugs used in adult cardiopulmonary resuscitation. 2002

Elsbeth Dyson, and Gary B Smith
Department of Intensive Care Medicine, Queen Alexandra Hospital, Portsmouth PO6 3LY, UK.

Successful advanced life support relies, in part, upon the availability and correct functioning of resuscitation equipment. However, numerous publications report deficiencies and defects in key items of resuscitation equipment, particularly those relating to airway management and defibrillation. Some of these are generic and relate to basic device failure (e.g. intrinsic design faults, manufacturing errors, random component failure), external factors (e.g. power failure, gas supply failure, electromagnetic interference) and human error (notably, inadequate knowledge, lack of experience and training, inadequate checking, insufficient maintenance). However, others are device specific. This paper identifies the common, generic faults that lead to equipment malfunction and recommends the resuscitation equipment essential for successful cardiopulmonary resuscitation. It also describes examples of specific equipment malfunction and makes suggestions for the nature and frequency of resuscitation equipment and drug checks, using a structured, and easy-to-recall list.

UI MeSH Term Description Entries
D008297 Male Males
D011785 Quality Assurance, Health Care Activities and programs intended to assure or improve the quality of care in either a defined medical setting or a program. The concept includes the assessment or evaluation of the quality of care; identification of problems or shortcomings in the delivery of care; designing activities to overcome these deficiencies; and follow-up monitoring to ensure effectiveness of corrective steps. Quality Assessment, Health Care,Health Care Quality Assessment,Health Care Quality Assurance,Healthcare Quality Assessment,Healthcare Quality Assurance,Quality Assessment, Healthcare,Quality Assurance, Healthcare,Assessment, Healthcare Quality,Assessments, Healthcare Quality,Assurance, Healthcare Quality,Assurances, Healthcare Quality,Healthcare Quality Assessments,Healthcare Quality Assurances,Quality Assessments, Healthcare,Quality Assurances, Healthcare
D004867 Equipment Design Methods and patterns of fabricating machines and related hardware. Design, Equipment,Device Design,Medical Device Design,Design, Medical Device,Designs, Medical Device,Device Design, Medical,Device Designs, Medical,Medical Device Designs,Design, Device,Designs, Device,Designs, Equipment,Device Designs,Equipment Designs
D004869 Equipment Safety Freedom of equipment from actual or potential hazards. Device Safety,Hazards, Equipment,Medical Device Safety,Safety, Equipment,Device Safety, Medical,Safety, Medical Device,Equipment Hazard,Equipment Hazards,Hazard, Equipment,Safety, Device
D005260 Female Females
D006113 United Kingdom Country in northwestern Europe including Great Britain and the northern one-sixth of the island of Ireland, located between the North Sea and north Atlantic Ocean. The capital is London. Great Britain,Isle of Man
D006323 Heart Arrest Cessation of heart beat or MYOCARDIAL CONTRACTION. If it is treated within a few minutes, heart arrest can be reversed in most cases to normal cardiac rhythm and effective circulation. Asystole,Cardiac Arrest,Cardiopulmonary Arrest,Arrest, Cardiac,Arrest, Cardiopulmonary,Arrest, Heart,Asystoles
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D012680 Sensitivity and Specificity Binary classification measures to assess test results. Sensitivity or recall rate is the proportion of true positives. Specificity is the probability of correctly determining the absence of a condition. (From Last, Dictionary of Epidemiology, 2d ed) Specificity,Sensitivity,Specificity and Sensitivity
D016887 Cardiopulmonary Resuscitation The artificial substitution of heart and lung action as indicated for HEART ARREST resulting from electric shock, DROWNING, respiratory arrest, or other causes. The two major components of cardiopulmonary resuscitation are artificial ventilation (RESPIRATION, ARTIFICIAL) and closed-chest CARDIAC MASSAGE. Basic Cardiac Life Support,CPR,Code Blue,Mouth-to-Mouth Resuscitation,Cardio-Pulmonary Resuscitation,Life Support, Basic Cardiac,Cardio Pulmonary Resuscitation,Mouth to Mouth Resuscitation,Mouth-to-Mouth Resuscitations,Resuscitation, Cardio-Pulmonary,Resuscitation, Cardiopulmonary,Resuscitation, Mouth-to-Mouth,Resuscitations, Mouth-to-Mouth

Related Publications

Elsbeth Dyson, and Gary B Smith
January 2001, Nursing times,
Elsbeth Dyson, and Gary B Smith
January 1975, Bulletin of the Parenteral Drug Association,
Elsbeth Dyson, and Gary B Smith
June 2021, Revue medicale suisse,
Elsbeth Dyson, and Gary B Smith
February 2017, Nursing standard (Royal College of Nursing (Great Britain) : 1987),
Elsbeth Dyson, and Gary B Smith
August 2011, Zhonghua nei ke za zhi,
Elsbeth Dyson, and Gary B Smith
February 1999, Tidsskrift for den Norske laegeforening : tidsskrift for praktisk medicin, ny raekke,
Elsbeth Dyson, and Gary B Smith
February 1999, Tidsskrift for den Norske laegeforening : tidsskrift for praktisk medicin, ny raekke,
Elsbeth Dyson, and Gary B Smith
January 2010, Medicina (Kaunas, Lithuania),
Elsbeth Dyson, and Gary B Smith
June 2005, JAMA,
Elsbeth Dyson, and Gary B Smith
August 1993, Tidsskrift for den Norske laegeforening : tidsskrift for praktisk medicin, ny raekke,
Copied contents to your clipboard!