Observer variation in the sonographic measurement of optic nerve sheath diameter in normal adults. 2002

S A Ballantyne, and G O'Neill, and R Hamilton, and A S Hollman
Department of Radiology and Clinical Physics, Royal Hospital for Sick Children, G46 7PD, Glasgow, UK. s.ballantyne@virgin.net

OBJECTIVE To quantify the observer variation in the sonographic measurement of optic nerve sheath diameter (ONSD) in normal adults. METHODS Sixty-seven normal adult volunteers underwent ultrasound examination of each eye by three independent observers using a 7 MHz sector probe. Three measurements were made of each eye by each observer and a mean value calculated for each eye. Median and 5th-95th centile values for both intra- and inter-observer variation were calculated for the three observers. RESULTS The median intra-observer variation was +/-0.1 mm, with 5th-95th centile values of +/-0-0.4 mm. The median inter-observer variation was +/-0.2-0.3 mm, with 5th-95th centile values of +/-0-0.7 mm. Careful review of examination technique by the three observers after the first 17 examinations was shown to reduce both intra- and inter-observer variation. CONCLUSIONS The sonographic measurement of ONSD is a readily learned, reproducible technique with low intra- and inter-observer variation. The average inter-observer variation (+/-0.2 mm) is comparable to the inherent variability of the ultrasound machine. The importance of standardisation of examination technique is stressed.

UI MeSH Term Description Entries
D008297 Male Males
D008875 Middle Aged An adult aged 45 - 64 years. Middle Age
D009186 Myelin Sheath The lipid-rich sheath surrounding AXONS in both the CENTRAL NERVOUS SYSTEMS and PERIPHERAL NERVOUS SYSTEM. The myelin sheath is an electrical insulator and allows faster and more energetically efficient conduction of impulses. The sheath is formed by the cell membranes of glial cells (SCHWANN CELLS in the peripheral and OLIGODENDROGLIA in the central nervous system). Deterioration of the sheath in DEMYELINATING DISEASES is a serious clinical problem. Myelin,Myelin Sheaths,Sheath, Myelin,Sheaths, Myelin
D009900 Optic Nerve The 2nd cranial nerve which conveys visual information from the RETINA to the brain. The nerve carries the axons of the RETINAL GANGLION CELLS which sort at the OPTIC CHIASM and continue via the OPTIC TRACTS to the brain. The largest projection is to the lateral geniculate nuclei; other targets include the SUPERIOR COLLICULI and the SUPRACHIASMATIC NUCLEI. Though known as the second cranial nerve, it is considered part of the CENTRAL NERVOUS SYSTEM. Cranial Nerve II,Second Cranial Nerve,Nervus Opticus,Cranial Nerve, Second,Cranial Nerves, Second,Nerve, Optic,Nerve, Second Cranial,Nerves, Optic,Nerves, Second Cranial,Optic Nerves,Second Cranial Nerves
D005260 Female Females
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D000328 Adult A person having attained full growth or maturity. Adults are of 19 through 44 years of age. For a person between 19 and 24 years of age, YOUNG ADULT is available. Adults
D014463 Ultrasonography The visualization of deep structures of the body by recording the reflections or echoes of ultrasonic pulses directed into the tissues. Use of ultrasound for imaging or diagnostic purposes employs frequencies ranging from 1.6 to 10 megahertz. Echography,Echotomography,Echotomography, Computer,Sonography, Medical,Tomography, Ultrasonic,Ultrasonic Diagnosis,Ultrasonic Imaging,Ultrasonographic Imaging,Computer Echotomography,Diagnosis, Ultrasonic,Diagnostic Ultrasound,Ultrasonic Tomography,Ultrasound Imaging,Diagnoses, Ultrasonic,Diagnostic Ultrasounds,Imaging, Ultrasonic,Imaging, Ultrasonographic,Imaging, Ultrasound,Imagings, Ultrasonographic,Imagings, Ultrasound,Medical Sonography,Ultrasonic Diagnoses,Ultrasonographic Imagings,Ultrasound, Diagnostic,Ultrasounds, Diagnostic
D015203 Reproducibility of Results The statistical reproducibility of measurements (often in a clinical context), including the testing of instrumentation or techniques to obtain reproducible results. The concept includes reproducibility of physiological measurements, which may be used to develop rules to assess probability or prognosis, or response to a stimulus; reproducibility of occurrence of a condition; and reproducibility of experimental results. Reliability and Validity,Reliability of Result,Reproducibility Of Result,Reproducibility of Finding,Validity of Result,Validity of Results,Face Validity,Reliability (Epidemiology),Reliability of Results,Reproducibility of Findings,Test-Retest Reliability,Validity (Epidemiology),Finding Reproducibilities,Finding Reproducibility,Of Result, Reproducibility,Of Results, Reproducibility,Reliabilities, Test-Retest,Reliability, Test-Retest,Result Reliabilities,Result Reliability,Result Validities,Result Validity,Result, Reproducibility Of,Results, Reproducibility Of,Test Retest Reliability,Validity and Reliability,Validity, Face
D015588 Observer Variation The failure by the observer to measure or identify a phenomenon accurately, which results in an error. Sources for this may be due to the observer's missing an abnormality, or to faulty technique resulting in incorrect test measurement, or to misinterpretation of the data. Two varieties are inter-observer variation (the amount observers vary from one another when reporting on the same material) and intra-observer variation (the amount one observer varies between observations when reporting more than once on the same material). Bias, Observer,Interobserver Variation,Intraobserver Variation,Observer Bias,Inter-Observer Variability,Inter-Observer Variation,Interobserver Variability,Intra-Observer Variability,Intra-Observer Variation,Intraobserver Variability,Inter Observer Variability,Inter Observer Variation,Inter-Observer Variabilities,Inter-Observer Variations,Interobserver Variabilities,Interobserver Variations,Intra Observer Variability,Intra Observer Variation,Intra-Observer Variabilities,Intra-Observer Variations,Intraobserver Variabilities,Intraobserver Variations,Observer Variations,Variabilities, Inter-Observer,Variabilities, Interobserver,Variabilities, Intra-Observer,Variabilities, Intraobserver,Variability, Inter-Observer,Variability, Interobserver,Variability, Intra-Observer,Variability, Intraobserver,Variation, Inter-Observer,Variation, Interobserver,Variation, Intra-Observer,Variation, Intraobserver,Variation, Observer,Variations, Inter-Observer,Variations, Interobserver,Variations, Intra-Observer,Variations, Intraobserver,Variations, Observer

Related Publications

S A Ballantyne, and G O'Neill, and R Hamilton, and A S Hollman
January 2014, The Malaysian journal of medical sciences : MJMS,
S A Ballantyne, and G O'Neill, and R Hamilton, and A S Hollman
July 2015, BMC neurology,
S A Ballantyne, and G O'Neill, and R Hamilton, and A S Hollman
December 2003, Journal of veterinary science,
S A Ballantyne, and G O'Neill, and R Hamilton, and A S Hollman
August 2015, The Kaohsiung journal of medical sciences,
S A Ballantyne, and G O'Neill, and R Hamilton, and A S Hollman
August 2019, The American journal of emergency medicine,
S A Ballantyne, and G O'Neill, and R Hamilton, and A S Hollman
January 2013, PloS one,
S A Ballantyne, and G O'Neill, and R Hamilton, and A S Hollman
February 2018, The American journal of emergency medicine,
S A Ballantyne, and G O'Neill, and R Hamilton, and A S Hollman
February 2018, European journal of neurology,
S A Ballantyne, and G O'Neill, and R Hamilton, and A S Hollman
November 2019, Nigerian journal of clinical practice,
Copied contents to your clipboard!