Real-time three-dimensional color doppler evaluation of the flow convergence zone for quantification of mitral regurgitation: Validation experimental animal study and initial clinical experience. 2003

Marta Sitges, and Michael Jones, and Takahiro Shiota, and Jian Xin Qin, and Hiroyuki Tsujino, and Fabrice Bauer, and Yong Jin Kim, and Deborah A Agler, and Lisa A Cardon, and Arthur D Zetts, and Julio A Panza, and James D Thomas
Cardiovascular Imaging Center, Department of Cardiovascular Medicine, The Cleveland Clinic Foundation, Cleveland, Ohio 44195, USA.

BACKGROUND Pitfalls of the flow convergence (FC) method, including 2-dimensional imaging of the 3-dimensional (3D) geometry of the FC surface, can lead to erroneous quantification of mitral regurgitation (MR). This limitation may be mitigated by the use of real-time 3D color Doppler echocardiography (CE). Our objective was to validate a real-time 3D navigation method for MR quantification. METHODS In 12 sheep with surgically induced chronic MR, 37 different hemodynamic conditions were studied with real-time 3DCE. Using real-time 3D navigation, the radius of the largest hemispherical FC zone was located and measured. MR volume was quantified according to the FC method after observing the shape of FC in 3D space. Aortic and mitral electromagnetic flow probes and meters were balanced against each other to determine reference MR volume. As an initial clinical application study, 22 patients with chronic MR were also studied with this real-time 3DCE-FC method. Left ventricular (LV) outflow tract automated cardiac flow measurement (Toshiba Corp, Tokyo, Japan) and real-time 3D LV stroke volume were used to quantify the reference MR volume (MR volume = 3DLV stroke volume - automated cardiac flow measurement). RESULTS In the sheep model, a good correlation and agreement was seen between MR volume by real-time 3DCE and electromagnetic (y = 0.77x + 1.48, r = 0.87, P <.001, delta = -0.91 +/- 2.65 mL). In patients, real-time 3DCE-derived MR volume also showed a good correlation and agreement with the reference method (y = 0.89x - 0.38, r = 0.93, P <.001, delta = -4.8 +/- 7.6 mL). CONCLUSIONS real-time 3DCE can capture the entire FC image, permitting geometrical recognition of the FC zone geometry and reliable MR quantification.

UI MeSH Term Description Entries
D007089 Image Enhancement Improvement of the quality of a picture by various techniques, including computer processing, digital filtering, echocardiographic techniques, light and ultrastructural MICROSCOPY, fluorescence spectrometry and microscopy, scintigraphy, and in vitro image processing at the molecular level. Image Quality Enhancement,Enhancement, Image,Enhancement, Image Quality,Enhancements, Image,Enhancements, Image Quality,Image Enhancements,Image Quality Enhancements,Quality Enhancement, Image,Quality Enhancements, Image
D008297 Male Males
D008875 Middle Aged An adult aged 45 - 64 years. Middle Age
D008944 Mitral Valve Insufficiency Backflow of blood from the LEFT VENTRICLE into the LEFT ATRIUM due to imperfect closure of the MITRAL VALVE. This can lead to mitral valve regurgitation. Mitral Incompetence,Mitral Regurgitation,Mitral Valve Incompetence,Mitral Insufficiency,Mitral Valve Regurgitation,Incompetence, Mitral,Incompetence, Mitral Valve,Insufficiency, Mitral,Insufficiency, Mitral Valve,Regurgitation, Mitral,Regurgitation, Mitral Valve,Valve Incompetence, Mitral,Valve Insufficiency, Mitral,Valve Regurgitation, Mitral
D008955 Models, Cardiovascular Theoretical representations that simulate the behavior or activity of the cardiovascular system, processes, or phenomena; includes the use of mathematical equations, computers and other electronic equipment. Cardiovascular Model,Cardiovascular Models,Model, Cardiovascular
D003199 Computer Systems Systems composed of a computer or computers, peripheral equipment, such as disks, printers, and terminals, and telecommunications capabilities. Computer Architecture,Computer System,Computer Systems Development,Computer Systems Evaluation,Computer Systems Organization,Real Time System,Real-Time Systems,Organization, Computer Systems,Architecture, Computer,Architectures, Computer,Computer Architectures,Computer Systems Evaluations,Development, Computer Systems,Evaluation, Computer Systems,Evaluations, Computer Systems,Real Time Systems,Real-Time System,System, Computer,System, Real Time,System, Real-Time,Systems, Computer,Systems, Real Time,Systems, Real-Time,Time System, Real,Time Systems, Real
D004195 Disease Models, Animal Naturally-occurring or experimentally-induced animal diseases with pathological processes analogous to human diseases. Animal Disease Model,Animal Disease Models,Disease Model, Animal
D005260 Female Females
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D000328 Adult A person having attained full growth or maturity. Adults are of 19 through 44 years of age. For a person between 19 and 24 years of age, YOUNG ADULT is available. Adults

Related Publications

Marta Sitges, and Michael Jones, and Takahiro Shiota, and Jian Xin Qin, and Hiroyuki Tsujino, and Fabrice Bauer, and Yong Jin Kim, and Deborah A Agler, and Lisa A Cardon, and Arthur D Zetts, and Julio A Panza, and James D Thomas
July 2015, Echocardiography (Mount Kisco, N.Y.),
Marta Sitges, and Michael Jones, and Takahiro Shiota, and Jian Xin Qin, and Hiroyuki Tsujino, and Fabrice Bauer, and Yong Jin Kim, and Deborah A Agler, and Lisa A Cardon, and Arthur D Zetts, and Julio A Panza, and James D Thomas
March 2020, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography,
Marta Sitges, and Michael Jones, and Takahiro Shiota, and Jian Xin Qin, and Hiroyuki Tsujino, and Fabrice Bauer, and Yong Jin Kim, and Deborah A Agler, and Lisa A Cardon, and Arthur D Zetts, and Julio A Panza, and James D Thomas
September 2007, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography,
Marta Sitges, and Michael Jones, and Takahiro Shiota, and Jian Xin Qin, and Hiroyuki Tsujino, and Fabrice Bauer, and Yong Jin Kim, and Deborah A Agler, and Lisa A Cardon, and Arthur D Zetts, and Julio A Panza, and James D Thomas
March 1996, Journal of the American College of Cardiology,
Marta Sitges, and Michael Jones, and Takahiro Shiota, and Jian Xin Qin, and Hiroyuki Tsujino, and Fabrice Bauer, and Yong Jin Kim, and Deborah A Agler, and Lisa A Cardon, and Arthur D Zetts, and Julio A Panza, and James D Thomas
May 1999, Journal of the American College of Cardiology,
Marta Sitges, and Michael Jones, and Takahiro Shiota, and Jian Xin Qin, and Hiroyuki Tsujino, and Fabrice Bauer, and Yong Jin Kim, and Deborah A Agler, and Lisa A Cardon, and Arthur D Zetts, and Julio A Panza, and James D Thomas
January 2010, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography,
Marta Sitges, and Michael Jones, and Takahiro Shiota, and Jian Xin Qin, and Hiroyuki Tsujino, and Fabrice Bauer, and Yong Jin Kim, and Deborah A Agler, and Lisa A Cardon, and Arthur D Zetts, and Julio A Panza, and James D Thomas
September 2002, Journal of the American College of Cardiology,
Marta Sitges, and Michael Jones, and Takahiro Shiota, and Jian Xin Qin, and Hiroyuki Tsujino, and Fabrice Bauer, and Yong Jin Kim, and Deborah A Agler, and Lisa A Cardon, and Arthur D Zetts, and Julio A Panza, and James D Thomas
March 1997, Annales de cardiologie et d'angeiologie,
Marta Sitges, and Michael Jones, and Takahiro Shiota, and Jian Xin Qin, and Hiroyuki Tsujino, and Fabrice Bauer, and Yong Jin Kim, and Deborah A Agler, and Lisa A Cardon, and Arthur D Zetts, and Julio A Panza, and James D Thomas
November 2008, JACC. Cardiovascular imaging,
Marta Sitges, and Michael Jones, and Takahiro Shiota, and Jian Xin Qin, and Hiroyuki Tsujino, and Fabrice Bauer, and Yong Jin Kim, and Deborah A Agler, and Lisa A Cardon, and Arthur D Zetts, and Julio A Panza, and James D Thomas
May 2007, The American journal of cardiology,
Copied contents to your clipboard!