A miniaturized load cell for lower extremity amputees. 1976

A J Moore, and J L Byers

The PRS-Moore Load Cell for below-knee and above-knee amputees that gives an audible warning when the wearer applies more than the predetermined weight on the affected limb is described. The sensing unit is a screw-adjustable compression spring that is enclosed in a machined housing that fits inside a machined base. Several prototypes have been produced and are now undergoing clinical analysis.

UI MeSH Term Description Entries
D007866 Leg The inferior part of the lower extremity between the KNEE and the ANKLE. Legs
D008124 Locomotion Movement or the ability to move from one place or another. It can refer to humans, vertebrate or invertebrate animals, and microorganisms. Locomotor Activity,Activities, Locomotor,Activity, Locomotor,Locomotor Activities
D011312 Pressure A type of stress exerted uniformly in all directions. Its measure is the force exerted per unit area. (McGraw-Hill Dictionary of Scientific and Technical Terms, 6th ed) Pressures
D012046 Rehabilitation Restoration of human functions to the maximum degree possible in a person or persons suffering from disease or injury. Habilitation
D005069 Evaluation Studies as Topic Works about studies that determine the effectiveness or value of processes, personnel, and equipment, or the material on conducting such studies. Critique,Evaluation Indexes,Evaluation Methodology,Evaluation Report,Evaluation Research,Methodology, Evaluation,Pre-Post Tests,Qualitative Evaluation,Quantitative Evaluation,Theoretical Effectiveness,Use-Effectiveness,Critiques,Effectiveness, Theoretical,Evaluation Methodologies,Evaluation Reports,Evaluation, Qualitative,Evaluation, Quantitative,Evaluations, Qualitative,Evaluations, Quantitative,Indexes, Evaluation,Methodologies, Evaluation,Pre Post Tests,Pre-Post Test,Qualitative Evaluations,Quantitative Evaluations,Report, Evaluation,Reports, Evaluation,Research, Evaluation,Test, Pre-Post,Tests, Pre-Post,Use Effectiveness
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D001186 Artificial Limbs Prosthetic replacements for arms, legs, and parts thereof. Arm Prosthesis,Arm, Artificial,Artificial Arm,Artificial Leg,Extremities, Artificial,Leg Prosthesis,Leg, Artificial,Limb Prosthesis,Limbs, Artificial,Arm Prostheses,Arms, Artificial,Artificial Arms,Artificial Extremities,Artificial Extremity,Artificial Legs,Artificial Limb,Extremity, Artificial,Leg Prostheses,Legs, Artificial,Limb Prostheses,Limb, Artificial,Prostheses, Arm,Prostheses, Leg,Prostheses, Limb,Prosthesis, Arm,Prosthesis, Leg,Prosthesis, Limb
D001698 Biomedical Engineering Application of principles and practices of engineering science to biomedical research and health care. Clinical Engineering,Engineering, Clinical,Engineering, Biomedical
D013314 Stress, Mechanical A purely physical condition which exists within any material because of strain or deformation by external forces or by non-uniform thermal expansion; expressed quantitatively in units of force per unit area. Mechanical Stress,Mechanical Stresses,Stresses, Mechanical

Related Publications

A J Moore, and J L Byers
June 1977, Physical therapy,
A J Moore, and J L Byers
November 1954, Archives of physical medicine and rehabilitation,
A J Moore, and J L Byers
December 2014, Plastic and reconstructive surgery,
A J Moore, and J L Byers
October 1961, Archives of physical medicine and rehabilitation,
A J Moore, and J L Byers
November 1960, The Bulletin of the Tulane Medical Faculty,
A J Moore, and J L Byers
July 1986, Ugeskrift for laeger,
A J Moore, and J L Byers
October 1965, Physical therapy,
A J Moore, and J L Byers
June 1965, Archives of physical medicine and rehabilitation,
A J Moore, and J L Byers
February 1967, JAMA,
A J Moore, and J L Byers
June 1980, The Medical journal of Australia,
Copied contents to your clipboard!