Ultra-low-dose coronary artery calcium screening using multislice CT with retrospective ECG gating. 2003

Tobias F Jakobs, and Bernd J Wintersperger, and Peter Herzog, and Thomas Flohr, and Christoph Suess, and Andreas Knez, and Maximilian F Reiser, and Christoph R Becker
Department of Clinical Radiology, University of Munich, Klinikum Grosshadern, Marchioninistrasse 15, 81377 Munich, Germany. tobias.jakobs@ikra.med.uni-muenchen.de

The aim of this study was to reduce radiation exposure in multislice CT (MSCT) coronary artery calcium screening using different tube settings, and to determinate its impact on the detection and quantification of coronary artery calcification. Forty-eight patients underwent routine MSCT coronary artery calcium scoring (Somatom VolumeZoom, Siemens, Forchheim, Germany) with retrospective ECG-gated data acquisition. Scanning was performed with a 4 x 2.5-mm collimation. In each patient data acquisition was performed twice using tube settings of 120 kVp with 133 mAs (protocol 1) and of 80 kVp with 300 mAs (protocol 2). Together with the 80-kVp protocol additional online ECG-related tube current modulation (ECG pulsing) was used. Three-millimeter overlapping slices (increment 1.5 mm) were calculated for each data set. Semi-automated calcium quantification was performed calculating absolute Ca-hydroxylapatite mass. In addition to patient examinations, the radiation exposure for both protocols was evaluated using computed tomography dose index (CTDI) phantom measurements. Protocol 2 showed a significantly lower patient radiation exposure than protocol 1 (0.72 vs 2.04 mSv; p<0.0001). The CTDI phantom measurements revealed a 65% reduction of radiation dose. Calcium scoring results of both protocols showed a high correlation ( r=0.99; p<0.0001) for absolute Ca-Hydroxylapatite mass measurements. Using 80-kVp protocols patient radiation exposure can be significantly reduced in MSCT coronary artery calcium screening without affecting the detection and quantification of coronary artery calcification; therefore, this technique should be used with retrospective ECG-gated cardiac CT examinations in patients with regular sinus rhythm.

UI MeSH Term Description Entries
D008297 Male Males
D008875 Middle Aged An adult aged 45 - 64 years. Middle Age
D011829 Radiation Dosage The amount of radiation energy that is deposited in a unit mass of material, such as tissues of plants or animal. In RADIOTHERAPY, radiation dosage is expressed in gray units (Gy). In RADIOLOGIC HEALTH, the dosage is expressed by the product of absorbed dose (Gy) and quality factor (a function of linear energy transfer), and is called radiation dose equivalent in sievert units (Sv). Sievert Units,Dosage, Radiation,Gray Units,Gy Radiation,Sv Radiation Dose Equivalent,Dosages, Radiation,Radiation Dosages,Units, Gray,Units, Sievert
D002114 Calcinosis Pathologic deposition of calcium salts in tissues. Calcification, Pathologic,Calcinosis, Tumoral,Microcalcification,Microcalcinosis,Pathologic Calcification,Calcinoses,Calcinoses, Tumoral,Microcalcifications,Microcalcinoses,Tumoral Calcinoses,Tumoral Calcinosis
D003327 Coronary Disease An imbalance between myocardial functional requirements and the capacity of the CORONARY VESSELS to supply sufficient blood flow. It is a form of MYOCARDIAL ISCHEMIA (insufficient blood supply to the heart muscle) caused by a decreased capacity of the coronary vessels. Coronary Heart Disease,Coronary Diseases,Coronary Heart Diseases,Disease, Coronary,Disease, Coronary Heart,Diseases, Coronary,Diseases, Coronary Heart,Heart Disease, Coronary,Heart Diseases, Coronary
D004562 Electrocardiography Recording of the moment-to-moment electromotive forces of the HEART as projected onto various sites on the body's surface, delineated as a scalar function of time. The recording is monitored by a tracing on slow moving chart paper or by observing it on a cardioscope, which is a CATHODE RAY TUBE DISPLAY. 12-Lead ECG,12-Lead EKG,12-Lead Electrocardiography,Cardiography,ECG,EKG,Electrocardiogram,Electrocardiograph,12 Lead ECG,12 Lead EKG,12 Lead Electrocardiography,12-Lead ECGs,12-Lead EKGs,12-Lead Electrocardiographies,Cardiographies,ECG, 12-Lead,EKG, 12-Lead,Electrocardiograms,Electrocardiographies, 12-Lead,Electrocardiographs,Electrocardiography, 12-Lead
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D014057 Tomography, X-Ray Computed Tomography using x-ray transmission and a computer algorithm to reconstruct the image. CAT Scan, X-Ray,CT Scan, X-Ray,Cine-CT,Computerized Tomography, X-Ray,Electron Beam Computed Tomography,Tomodensitometry,Tomography, Transmission Computed,X-Ray Tomography, Computed,CAT Scan, X Ray,CT X Ray,Computed Tomography, X-Ray,Computed X Ray Tomography,Computerized Tomography, X Ray,Electron Beam Tomography,Tomography, X Ray Computed,Tomography, X-Ray Computer Assisted,Tomography, X-Ray Computerized,Tomography, X-Ray Computerized Axial,Tomography, Xray Computed,X Ray Computerized Tomography,X Ray Tomography, Computed,X-Ray Computer Assisted Tomography,X-Ray Computerized Axial Tomography,Beam Tomography, Electron,CAT Scans, X-Ray,CT Scan, X Ray,CT Scans, X-Ray,CT X Rays,Cine CT,Computed Tomography, Transmission,Computed Tomography, X Ray,Computed Tomography, Xray,Computed X-Ray Tomography,Scan, X-Ray CAT,Scan, X-Ray CT,Scans, X-Ray CAT,Scans, X-Ray CT,Tomographies, Computed X-Ray,Tomography, Computed X-Ray,Tomography, Electron Beam,Tomography, X Ray Computer Assisted,Tomography, X Ray Computerized,Tomography, X Ray Computerized Axial,Transmission Computed Tomography,X Ray Computer Assisted Tomography,X Ray Computerized Axial Tomography,X Ray, CT,X Rays, CT,X-Ray CAT Scan,X-Ray CAT Scans,X-Ray CT Scan,X-Ray CT Scans,X-Ray Computed Tomography,X-Ray Computerized Tomography,Xray Computed Tomography
D017886 Durapatite The mineral component of bones and teeth; it has been used therapeutically as a prosthetic aid and in the prevention and treatment of osteoporosis. Calcium Hydroxyapatite,Hydroxyapatite,Hydroxylapatite,Alveograf,Calcitite,Interpore-200,Interpore-500,Osprovit,Ossein-Hydroxyapatite Compound,Ossopan,Osteogen,Periograf,Hydroxyapatite, Calcium,Interpore 200,Interpore 500,Interpore200,Interpore500,Ossein Hydroxyapatite Compound
D019047 Phantoms, Imaging Devices or objects in various imaging techniques used to visualize or enhance visualization by simulating conditions encountered in the procedure. Phantoms are used very often in procedures employing or measuring x-irradiation or radioactive material to evaluate performance. Phantoms often have properties similar to human tissue. Water demonstrates absorbing properties similar to normal tissue, hence water-filled phantoms are used to map radiation levels. Phantoms are used also as teaching aids to simulate real conditions with x-ray or ultrasonic machines. (From Iturralde, Dictionary and Handbook of Nuclear Medicine and Clinical Imaging, 1990) Phantoms, Radiographic,Phantoms, Radiologic,Radiographic Phantoms,Radiologic Phantoms,Phantom, Radiographic,Phantom, Radiologic,Radiographic Phantom,Radiologic Phantom,Imaging Phantom,Imaging Phantoms,Phantom, Imaging

Related Publications

Tobias F Jakobs, and Bernd J Wintersperger, and Peter Herzog, and Thomas Flohr, and Christoph Suess, and Andreas Knez, and Maximilian F Reiser, and Christoph R Becker
December 2001, AJR. American journal of roentgenology,
Tobias F Jakobs, and Bernd J Wintersperger, and Peter Herzog, and Thomas Flohr, and Christoph Suess, and Andreas Knez, and Maximilian F Reiser, and Christoph R Becker
January 2010, Biomedical imaging and intervention journal,
Tobias F Jakobs, and Bernd J Wintersperger, and Peter Herzog, and Thomas Flohr, and Christoph Suess, and Andreas Knez, and Maximilian F Reiser, and Christoph R Becker
July 2004, AJR. American journal of roentgenology,
Tobias F Jakobs, and Bernd J Wintersperger, and Peter Herzog, and Thomas Flohr, and Christoph Suess, and Andreas Knez, and Maximilian F Reiser, and Christoph R Becker
August 2000, AJR. American journal of roentgenology,
Tobias F Jakobs, and Bernd J Wintersperger, and Peter Herzog, and Thomas Flohr, and Christoph Suess, and Andreas Knez, and Maximilian F Reiser, and Christoph R Becker
January 2008, European heart journal,
Tobias F Jakobs, and Bernd J Wintersperger, and Peter Herzog, and Thomas Flohr, and Christoph Suess, and Andreas Knez, and Maximilian F Reiser, and Christoph R Becker
January 2010, Radiologia,
Tobias F Jakobs, and Bernd J Wintersperger, and Peter Herzog, and Thomas Flohr, and Christoph Suess, and Andreas Knez, and Maximilian F Reiser, and Christoph R Becker
October 2021, The Indian journal of radiology & imaging,
Tobias F Jakobs, and Bernd J Wintersperger, and Peter Herzog, and Thomas Flohr, and Christoph Suess, and Andreas Knez, and Maximilian F Reiser, and Christoph R Becker
April 2008, AJR. American journal of roentgenology,
Tobias F Jakobs, and Bernd J Wintersperger, and Peter Herzog, and Thomas Flohr, and Christoph Suess, and Andreas Knez, and Maximilian F Reiser, and Christoph R Becker
July 2011, Journal of cardiovascular medicine (Hagerstown, Md.),
Tobias F Jakobs, and Bernd J Wintersperger, and Peter Herzog, and Thomas Flohr, and Christoph Suess, and Andreas Knez, and Maximilian F Reiser, and Christoph R Becker
February 2023, European radiology,
Copied contents to your clipboard!