Clinical observations with a dual sensor rate adaptive single chamber pacemaker. 1992

F Provenier, and R van Acker, and J Backers, and E van Wassenhove, and V de Meyer, and L Jordaens
Department of Cardiology, University Hospital, Ghent, Belgium.

The Topaz model 515 (Vitatron B.V.) is a dual sensor rate responsive pacemaker for single chamber stimulation. It can be driven by activity counts (ACT) and QT interval measurements. Inappropriate rate modulation due to one sensor can be corrected by "sensor cross-checking." It was implanted in ten patients (20-86 years) of whom seven had complete heart block and atrial arrhythmias. After implantation T-wave amplitude ranged from 0.9 mV-3.5 mV. T-wave sensing ranged from 88%-99% in 9/10 patients at the follow-up of 3 weeks. Eight patients remained in default setting of the activity threshold, after evaluation with a short walking test. An exercise test was performed on all patients. In one test, QT sensing was marginal because of lead implantation in the right ventricular outflow tract. Therefore, this pacing rate was only modulated by ACT sensing. All others were tested with equal contribution of information from both sensors (ACT = QT). In 7/9, rate response was satisfactory. When the treadmill was repeated with ACT in five of these seven patients, rate generally accelerated too fast. In one patient the setting was adjusted to "QT > ACT," because of inappropriate acceleration due to activity sensing, in another it was adjusted to "QT < ACT" because of delayed response to activity. The pacing rate and the ACT during treadmill tests in "QT = ACT" mode were more closely correlated in the first 3 minutes, compared with the last 3 minutes. We feel that rate modulation with this new pacemaker is adequate. Sensor blending and sensor cross-checking are of clinical importance.

UI MeSH Term Description Entries
D008297 Male Males
D008875 Middle Aged An adult aged 45 - 64 years. Middle Age
D010138 Pacemaker, Artificial A device designed to stimulate, by electric impulses, contraction of the heart muscles. It may be temporary (external) or permanent (internal or internal-external). Cardiac Pacemaker, Artificial,Artificial Cardiac Pacemaker,Artificial Cardiac Pacemakers,Artificial Pacemaker,Artificial Pacemakers,Cardiac Pacemakers, Artificial,Pacemaker, Artificial Cardiac,Pacemakers, Artificial,Pacemakers, Artificial Cardiac
D002304 Cardiac Pacing, Artificial Regulation of the rate of contraction of the heart muscles by an artificial pacemaker. Pacing, Cardiac, Artificial,Artificial Cardiac Pacing,Artificial Cardiac Pacings,Cardiac Pacings, Artificial,Pacing, Artificial Cardiac,Pacings, Artificial Cardiac
D004867 Equipment Design Methods and patterns of fabricating machines and related hardware. Design, Equipment,Device Design,Medical Device Design,Design, Medical Device,Designs, Medical Device,Device Design, Medical,Device Designs, Medical,Medical Device Designs,Design, Device,Designs, Device,Designs, Equipment,Device Designs,Equipment Designs
D005080 Exercise Test Controlled physical activity which is performed in order to allow assessment of physiological functions, particularly cardiovascular and pulmonary, but also aerobic capacity. Maximal (most intense) exercise is usually required but submaximal exercise is also used. Arm Ergometry Test,Bicycle Ergometry Test,Cardiopulmonary Exercise Testing,Exercise Testing,Step Test,Stress Test,Treadmill Test,Cardiopulmonary Exercise Test,EuroFit Tests,Eurofit Test Battery,European Fitness Testing Battery,Fitness Testing,Physical Fitness Testing,Arm Ergometry Tests,Bicycle Ergometry Tests,Cardiopulmonary Exercise Tests,Ergometry Test, Arm,Ergometry Test, Bicycle,Ergometry Tests, Arm,Ergometry Tests, Bicycle,EuroFit Test,Eurofit Test Batteries,Exercise Test, Cardiopulmonary,Exercise Testing, Cardiopulmonary,Exercise Tests,Exercise Tests, Cardiopulmonary,Fitness Testing, Physical,Fitness Testings,Step Tests,Stress Tests,Test Battery, Eurofit,Test, Arm Ergometry,Test, Bicycle Ergometry,Test, Cardiopulmonary Exercise,Test, EuroFit,Test, Exercise,Test, Step,Test, Stress,Test, Treadmill,Testing, Cardiopulmonary Exercise,Testing, Exercise,Testing, Fitness,Testing, Physical Fitness,Tests, Arm Ergometry,Tests, Bicycle Ergometry,Tests, Cardiopulmonary Exercise,Tests, EuroFit,Tests, Exercise,Tests, Step,Tests, Stress,Tests, Treadmill,Treadmill Tests
D005260 Female Females
D006327 Heart Block Impaired conduction of cardiac impulse that can occur anywhere along the conduction pathway, such as between the SINOATRIAL NODE and the right atrium (SA block) or between atria and ventricles (AV block). Heart blocks can be classified by the duration, frequency, or completeness of conduction block. Reversibility depends on the degree of structural or functional defects. Auriculo-Ventricular Dissociation,A-V Dissociation,Atrioventricular Dissociation,A V Dissociation,A-V Dissociations,Atrioventricular Dissociations,Auriculo Ventricular Dissociation,Auriculo-Ventricular Dissociations,Block, Heart,Blocks, Heart,Dissociation, A-V,Dissociation, Atrioventricular,Dissociation, Auriculo-Ventricular,Dissociations, A-V,Dissociations, Atrioventricular,Dissociations, Auriculo-Ventricular,Heart Blocks
D006339 Heart Rate The number of times the HEART VENTRICLES contract per unit of time, usually per minute. Cardiac Rate,Chronotropism, Cardiac,Heart Rate Control,Heartbeat,Pulse Rate,Cardiac Chronotropy,Cardiac Chronotropism,Cardiac Rates,Chronotropy, Cardiac,Control, Heart Rate,Heart Rates,Heartbeats,Pulse Rates,Rate Control, Heart,Rate, Cardiac,Rate, Heart,Rate, Pulse
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man

Related Publications

F Provenier, and R van Acker, and J Backers, and E van Wassenhove, and V de Meyer, and L Jordaens
September 1993, Pacing and clinical electrophysiology : PACE,
F Provenier, and R van Acker, and J Backers, and E van Wassenhove, and V de Meyer, and L Jordaens
November 1994, Pacing and clinical electrophysiology : PACE,
F Provenier, and R van Acker, and J Backers, and E van Wassenhove, and V de Meyer, and L Jordaens
May 1995, Pacing and clinical electrophysiology : PACE,
F Provenier, and R van Acker, and J Backers, and E van Wassenhove, and V de Meyer, and L Jordaens
November 2002, The Veterinary record,
F Provenier, and R van Acker, and J Backers, and E van Wassenhove, and V de Meyer, and L Jordaens
April 1993, Pacing and clinical electrophysiology : PACE,
F Provenier, and R van Acker, and J Backers, and E van Wassenhove, and V de Meyer, and L Jordaens
November 1992, Pacing and clinical electrophysiology : PACE,
F Provenier, and R van Acker, and J Backers, and E van Wassenhove, and V de Meyer, and L Jordaens
December 2002, Pediatrics international : official journal of the Japan Pediatric Society,
F Provenier, and R van Acker, and J Backers, and E van Wassenhove, and V de Meyer, and L Jordaens
November 1994, Pacing and clinical electrophysiology : PACE,
F Provenier, and R van Acker, and J Backers, and E van Wassenhove, and V de Meyer, and L Jordaens
November 2010, The Canadian journal of cardiology,
F Provenier, and R van Acker, and J Backers, and E van Wassenhove, and V de Meyer, and L Jordaens
December 1991, The American journal of cardiology,
Copied contents to your clipboard!