High percentage of CD8+, Leu-7+ cells in rheumatoid arthritis synovial fluid. 1992

C M Burns, and V Tsai, and N J Zvaifler
Department of Medicine, University of California, San Diego.

OBJECTIVE While analyzing the phenotype of the synovial fluid mononuclear cells (SFMC) clustered about dendritic cells in rheumatoid arthritis (RA) joint effusions, it was noted that most of the clustering cells were CD8+ and coexpressed Leu-7. Therefore, the present study was conducted to investigate the frequency of CD8+, Leu-7+ cells in RA SF: METHODS SFMC from 13 patients with RA and from 12 patients with non-RA inflammatory arthritides were examined for CD8 and Leu-7 expression using 2-color immunofluorescence flow cytometry. RESULTS RA SFMC had statistically significantly greater percentages of total CD8+ cells, total Leu-7+ cells, and CD8+, Leu-7+ cells, compared with SFMC from the non-RA patients. These RA CD8+, Leu-7+ SFMC had a distinctive electron microscopic appearance compared with CD8+, Leu-7- SFMC. When peripheral blood mononuclear cells (PBMC) from 31 RA patients (including 7 from the SFMC group) were compared with PBMC from 15 normal controls, the percentage of CD8+, Leu-7+ cells was not significantly greater in the RA patients. However, the combination of a modest increase in CD8+, Leu-7+ cells and a decrease in total CD8 cells in RA PBMC altered the composition of the RA CD8 population compared with normal PBMC, such that over 40% of RA peripheral blood CD8 cells coexpressed Leu-7. CONCLUSIONS The increased frequency of CD8+, Leu-7+ cells in RA SFMC may arise from the fact that a high percentage of the CD8+ PBMC in RA patients are also Leu-7+. This altered composition of CD8 cells in RA SF may have a role in the pathogenesis of the disease.

UI MeSH Term Description Entries
D008854 Microscopy, Electron Microscopy using an electron beam, instead of light, to visualize the sample, thereby allowing much greater magnification. The interactions of ELECTRONS with specimens are used to provide information about the fine structure of that specimen. In TRANSMISSION ELECTRON MICROSCOPY the reactions of the electrons that are transmitted through the specimen are imaged. In SCANNING ELECTRON MICROSCOPY an electron beam falls at a non-normal angle on the specimen and the image is derived from the reactions occurring above the plane of the specimen. Electron Microscopy
D009000 Monocytes Large, phagocytic mononuclear leukocytes produced in the vertebrate BONE MARROW and released into the BLOOD; contain a large, oval or somewhat indented nucleus surrounded by voluminous cytoplasm and numerous organelles. Monocyte
D010641 Phenotype The outward appearance of the individual. It is the product of interactions between genes, and between the GENOTYPE and the environment. Phenotypes
D002452 Cell Count The number of CELLS of a specific kind, usually measured per unit volume or area of sample. Cell Density,Cell Number,Cell Counts,Cell Densities,Cell Numbers,Count, Cell,Counts, Cell,Densities, Cell,Density, Cell,Number, Cell,Numbers, Cell
D005434 Flow Cytometry Technique using an instrument system for making, processing, and displaying one or more measurements on individual cells obtained from a cell suspension. Cells are usually stained with one or more fluorescent dyes specific to cell components of interest, e.g., DNA, and fluorescence of each cell is measured as it rapidly transverses the excitation beam (laser or mercury arc lamp). Fluorescence provides a quantitative measure of various biochemical and biophysical properties of the cell, as well as a basis for cell sorting. Other measurable optical parameters include light absorption and light scattering, the latter being applicable to the measurement of cell size, shape, density, granularity, and stain uptake. Cytofluorometry, Flow,Cytometry, Flow,Flow Microfluorimetry,Fluorescence-Activated Cell Sorting,Microfluorometry, Flow,Cell Sorting, Fluorescence-Activated,Cell Sortings, Fluorescence-Activated,Cytofluorometries, Flow,Cytometries, Flow,Flow Cytofluorometries,Flow Cytofluorometry,Flow Cytometries,Flow Microfluorometries,Flow Microfluorometry,Fluorescence Activated Cell Sorting,Fluorescence-Activated Cell Sortings,Microfluorimetry, Flow,Microfluorometries, Flow,Sorting, Fluorescence-Activated Cell,Sortings, Fluorescence-Activated Cell
D005455 Fluorescent Antibody Technique Test for tissue antigen using either a direct method, by conjugation of antibody with fluorescent dye (FLUORESCENT ANTIBODY TECHNIQUE, DIRECT) or an indirect method, by formation of antigen-antibody complex which is then labeled with fluorescein-conjugated anti-immunoglobulin antibody (FLUORESCENT ANTIBODY TECHNIQUE, INDIRECT). The tissue is then examined by fluorescence microscopy. Antinuclear Antibody Test, Fluorescent,Coon's Technique,Fluorescent Antinuclear Antibody Test,Fluorescent Protein Tracing,Immunofluorescence Technique,Coon's Technic,Fluorescent Antibody Technic,Immunofluorescence,Immunofluorescence Technic,Antibody Technic, Fluorescent,Antibody Technics, Fluorescent,Antibody Technique, Fluorescent,Antibody Techniques, Fluorescent,Coon Technic,Coon Technique,Coons Technic,Coons Technique,Fluorescent Antibody Technics,Fluorescent Antibody Techniques,Fluorescent Protein Tracings,Immunofluorescence Technics,Immunofluorescence Techniques,Protein Tracing, Fluorescent,Protein Tracings, Fluorescent,Technic, Coon's,Technic, Fluorescent Antibody,Technic, Immunofluorescence,Technics, Fluorescent Antibody,Technics, Immunofluorescence,Technique, Coon's,Technique, Fluorescent Antibody,Technique, Immunofluorescence,Techniques, Fluorescent Antibody,Techniques, Immunofluorescence,Tracing, Fluorescent Protein,Tracings, Fluorescent Protein
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D000943 Antigens, Differentiation Antigens expressed primarily on the membranes of living cells during sequential stages of maturation and differentiation. As immunologic markers they have high organ and tissue specificity and are useful as probes in studies of normal cell development as well as neoplastic transformation. Differentiation Antigen,Differentiation Antigens,Differentiation Antigens, Hairy Cell Leukemia,Differentiation Marker,Differentiation Markers,Leu Antigen,Leu Antigens,Marker Antigen,Marker Antigens,Markers, Differentiation,Antigen, Differentiation,Antigen, Leu,Antigen, Marker,Antigens, Leu,Antigens, Marker,Marker, Differentiation
D001172 Arthritis, Rheumatoid A chronic systemic disease, primarily of the joints, marked by inflammatory changes in the synovial membranes and articular structures, widespread fibrinoid degeneration of the collagen fibers in mesenchymal tissues, and by atrophy and rarefaction of bony structures. Etiology is unknown, but autoimmune mechanisms have been implicated. Rheumatoid Arthritis
D013582 Synovial Fluid The clear, viscous fluid secreted by the SYNOVIAL MEMBRANE. It contains mucin, albumin, fat, and mineral salts and serves to lubricate joints. Synovia,Fluid, Synovial,Fluids, Synovial,Synovial Fluids

Related Publications

C M Burns, and V Tsai, and N J Zvaifler
October 2005, Rheumatology international,
C M Burns, and V Tsai, and N J Zvaifler
October 1997, Annals of the rheumatic diseases,
C M Burns, and V Tsai, and N J Zvaifler
August 2012, Journal of clinical immunology,
C M Burns, and V Tsai, and N J Zvaifler
January 1990, Journal of clinical laboratory analysis,
C M Burns, and V Tsai, and N J Zvaifler
August 1970, Annals of clinical research,
C M Burns, and V Tsai, and N J Zvaifler
September 1980, British medical journal,
C M Burns, and V Tsai, and N J Zvaifler
March 2004, Autoimmunity reviews,
C M Burns, and V Tsai, and N J Zvaifler
January 1980, Scandinavian journal of rheumatology,
C M Burns, and V Tsai, and N J Zvaifler
December 1958, Arthritis and rheumatism,
C M Burns, and V Tsai, and N J Zvaifler
January 2016, Clinical proteomics,
Copied contents to your clipboard!