Prospective validation of a single sample technique to determine technetium-99m-MAG3 clearance. 1992

A Taylor, and P Corrigan, and D Eshima, and R Folks
Department of Radiology, Emory University Medical Center, Atlanta, Georgia 30322.

Technetium-99m-MAG3 clearance is proportional to OIH clearance and can be used directly as a measure of renal function. Multiple plasma sample, two-compartment clearance data from three studies were recently pooled to develop a single-sample regression equation for determining the clearance of 99mTc-MAG3. To test this published equation, a prospective study was conducted in 34 patients with a wide range of renal function. Multiple plasma samples were obtained from 9 to 60 min following the bolus injection of 99mTc-MAG3 and the clearances were calculated based on a single injection, two-compartment model. Clearances were also calculated using a single 43-min plasma sample and the published regression equation. There was an excellent correlation (r = 0.976) between the two clearances; the slope of the regression line was 1.01 with an intercept of -26.6; the standard error of the estimate was 24 ml/min. In conclusion, the current regression equation provides a good estimate of 99mTc-MAG3 clearance.

UI MeSH Term Description Entries
D007457 Iodine Radioisotopes Unstable isotopes of iodine that decay or disintegrate emitting radiation. I atoms with atomic weights 117-139, except I 127, are radioactive iodine isotopes. Radioisotopes, Iodine
D007465 Iodohippuric Acid An iodine-containing compound used in pyelography as a radiopaque medium. If labeled with radioiodine, it can be used for studies of renal function. Iodobenzoylglycine,Sodium Iodohippurate,I-Hippuran,I-OIH,Orthoiodohippurate,Radio-Hippuran,Sodium o-Iodohippurate,ortho-Iodohippurate,Acid, Iodohippuric,I Hippuran,I OIH,Iodohippurate, Sodium,Radio Hippuran,RadioHippuran,Sodium o Iodohippurate,o-Iodohippurate, Sodium,ortho Iodohippurate
D007668 Kidney Body organ that filters blood for the secretion of URINE and that regulates ion concentrations. Kidneys
D008657 Metabolic Clearance Rate Volume of biological fluid completely cleared of drug metabolites as measured in unit time. Elimination occurs as a result of metabolic processes in the kidney, liver, saliva, sweat, intestine, heart, brain, or other site. Total Body Clearance Rate,Clearance Rate, Metabolic,Clearance Rates, Metabolic,Metabolic Clearance Rates,Rate, Metabolic Clearance,Rates, Metabolic Clearance
D009842 Oligopeptides Peptides composed of between two and twelve amino acids. Oligopeptide
D011446 Prospective Studies Observation of a population for a sufficient number of persons over a sufficient number of years to generate incidence or mortality rates subsequent to the selection of the study group. Prospective Study,Studies, Prospective,Study, Prospective
D012044 Regression Analysis Procedures for finding the mathematical function which best describes the relationship between a dependent variable and one or more independent variables. In linear regression (see LINEAR MODELS) the relationship is constrained to be a straight line and LEAST-SQUARES ANALYSIS is used to determine the best fit. In logistic regression (see LOGISTIC MODELS) the dependent variable is qualitative rather than continuously variable and LIKELIHOOD FUNCTIONS are used to find the best relationship. In multiple regression, the dependent variable is considered to depend on more than a single independent variable. Regression Diagnostics,Statistical Regression,Analysis, Regression,Analyses, Regression,Diagnostics, Regression,Regression Analyses,Regression, Statistical,Regressions, Statistical,Statistical Regressions
D002851 Chromatography, High Pressure Liquid Liquid chromatographic techniques which feature high inlet pressures, high sensitivity, and high speed. Chromatography, High Performance Liquid,Chromatography, High Speed Liquid,Chromatography, Liquid, High Pressure,HPLC,High Performance Liquid Chromatography,High-Performance Liquid Chromatography,UPLC,Ultra Performance Liquid Chromatography,Chromatography, High-Performance Liquid,High-Performance Liquid Chromatographies,Liquid Chromatography, High-Performance
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D015609 Organotechnetium Compounds Organic compounds that contain technetium as an integral part of the molecule. These compounds are often used as radionuclide imaging agents. Compounds, Organotechnetium

Related Publications

A Taylor, and P Corrigan, and D Eshima, and R Folks
April 1995, Journal of nuclear medicine : official publication, Society of Nuclear Medicine,
A Taylor, and P Corrigan, and D Eshima, and R Folks
November 2021, Clinical physiology and functional imaging,
A Taylor, and P Corrigan, and D Eshima, and R Folks
June 1998, Journal of nuclear medicine : official publication, Society of Nuclear Medicine,
A Taylor, and P Corrigan, and D Eshima, and R Folks
November 1997, Journal of nuclear medicine : official publication, Society of Nuclear Medicine,
A Taylor, and P Corrigan, and D Eshima, and R Folks
November 1988, Journal of nuclear medicine : official publication, Society of Nuclear Medicine,
A Taylor, and P Corrigan, and D Eshima, and R Folks
December 1987, Journal of nuclear medicine : official publication, Society of Nuclear Medicine,
A Taylor, and P Corrigan, and D Eshima, and R Folks
November 1991, Journal of nuclear medicine : official publication, Society of Nuclear Medicine,
A Taylor, and P Corrigan, and D Eshima, and R Folks
August 1990, Journal of nuclear medicine : official publication, Society of Nuclear Medicine,
A Taylor, and P Corrigan, and D Eshima, and R Folks
September 2000, Journal of nuclear medicine technology,
A Taylor, and P Corrigan, and D Eshima, and R Folks
August 1996, Journal of nuclear medicine : official publication, Society of Nuclear Medicine,
Copied contents to your clipboard!