Automatic implantable cardioverter defibrillator: surgical approaches for implantation. 1992

R B Shepard, and M D Goldin, and G M Lawrie, and L Watkins, and R A Winkle, and M M Mower, and A C Thomas, and S Nisam
Department of Surgery, University of Alabama, Birmingham 35294.

Surgical approaches for implantation of the automatic cardioverter defibrillator are sternotomy, left thoracotomy, subxiphoid, and subcostal. Although any one of these may be combined with insertion of one or more of the electrodes transvenously, surgical entry into the chest is required for every noninvestigational defibrillator implantation operation. The approaches differ in exposure provided for selecting electrode sites and for handling untoward events, in amount and location of tissue that must be divided or dissected, and in average time required. The operation is an electrical one. Its purpose is to obtain reliable rhythm sensing so that defibrillation or cardioversion shocks will occur only when necessary, and to obtain low enough defibrillation thresholds for shocks of 30 joules or less to have a 10-joule defibrillation safety margin. Many of the patients have had previous cardiac operations. They usually have low or very low ejection fractions. Intraoperative electrophysiological testing with often multiple defibrillation episodes is required. The choice of approach varies with the state of the patient, the institutional experience, and the surgeon. This article describes technique, and the advantages and disadvantages of the four approaches as used by four surgeons in four different institutions.

UI MeSH Term Description Entries
D007430 Intraoperative Care Patient care procedures performed during the operation that are ancillary to the actual surgery. It includes monitoring, fluid therapy, medication, transfusion, anesthesia, radiography, and laboratory tests. Care, Intraoperative
D004567 Electrodes, Implanted Surgically placed electric conductors through which ELECTRIC STIMULATION is delivered to or electrical activity is recorded from a specific point inside the body. Implantable Electrodes,Implantable Stimulation Electrodes,Implanted Electrodes,Implanted Stimulation Electrodes,Electrode, Implantable,Electrode, Implantable Stimulation,Electrode, Implanted,Electrode, Implanted Stimulation,Electrodes, Implantable,Electrodes, Implantable Stimulation,Electrodes, Implanted Stimulation,Implantable Electrode,Implantable Stimulation Electrode,Implanted Electrode,Implanted Stimulation Electrode,Stimulation Electrode, Implantable,Stimulation Electrode, Implanted,Stimulation Electrodes, Implantable,Stimulation Electrodes, Implanted
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D012272 Ribs A set of twelve curved bones which connect to the vertebral column posteriorly, and terminate anteriorly as costal cartilage. Together, they form a protective cage around the internal thoracic organs. Rib
D013249 Sternum A long, narrow, and flat bone commonly known as BREASTBONE occurring in the midsection of the anterior thoracic segment or chest region, which stabilizes the rib cage and serves as the point of origin for several muscles that move the arms, head, and neck.
D013903 Thoracic Surgery A surgical specialty concerned with diagnosis and treatment of disorders of the heart, lungs, and esophagus. Two major types of thoracic surgery are classified as pulmonary and cardiovascular. Cardiac Surgery,Heart Surgery,Surgery, Cardiac,Surgery, Heart,Surgery, Thoracic
D013908 Thoracotomy Surgical incision into the chest wall. Thoracotomies
D014693 Ventricular Fibrillation A potentially lethal cardiac arrhythmia that is characterized by uncoordinated extremely rapid firing of electrical impulses (400-600/min) in HEART VENTRICLES. Such asynchronous ventricular quivering or fibrillation prevents any effective cardiac output and results in unconsciousness (SYNCOPE). It is one of the major electrocardiographic patterns seen with CARDIAC ARREST. Fibrillation, Ventricular,Fibrillations, Ventricular,Ventricular Fibrillations
D014989 Xiphoid Bone The smallest and most inferior triangular protrusion of the STERNUM or breastbone that extends into the center of the RIBCAGE. Xiphoid Process,Xiphoid Bones,Xiphoid Processes
D017147 Defibrillators, Implantable Implantable devices which continuously monitor the electrical activity of the heart and automatically detect and terminate ventricular tachycardia (TACHYCARDIA, VENTRICULAR) and VENTRICULAR FIBRILLATION. They consist of an impulse generator, batteries, and electrodes. Cardioverter-Defibrillators, Implantable,Implantable Cardioverter Defibrillator,Implantable Cardioverter-Defibrillators,Implantable Defibrillators,Cardioverter Defibrillator, Implantable,Cardioverter Defibrillators, Implantable,Cardioverter-Defibrillator, Implantable,Defibrillator, Implantable,Defibrillator, Implantable Cardioverter,Defibrillators, Implantable Cardioverter,Implantable Cardioverter Defibrillators,Implantable Cardioverter-Defibrillator,Implantable Defibrillator

Related Publications

R B Shepard, and M D Goldin, and G M Lawrie, and L Watkins, and R A Winkle, and M M Mower, and A C Thomas, and S Nisam
May 1991, Pacing and clinical electrophysiology : PACE,
R B Shepard, and M D Goldin, and G M Lawrie, and L Watkins, and R A Winkle, and M M Mower, and A C Thomas, and S Nisam
June 1993, The Annals of thoracic surgery,
R B Shepard, and M D Goldin, and G M Lawrie, and L Watkins, and R A Winkle, and M M Mower, and A C Thomas, and S Nisam
March 1988, Journal of cardiac surgery,
R B Shepard, and M D Goldin, and G M Lawrie, and L Watkins, and R A Winkle, and M M Mower, and A C Thomas, and S Nisam
September 1989, The Annals of thoracic surgery,
R B Shepard, and M D Goldin, and G M Lawrie, and L Watkins, and R A Winkle, and M M Mower, and A C Thomas, and S Nisam
December 1989, American heart journal,
R B Shepard, and M D Goldin, and G M Lawrie, and L Watkins, and R A Winkle, and M M Mower, and A C Thomas, and S Nisam
November 1988, The Journal of cardiovascular nursing,
R B Shepard, and M D Goldin, and G M Lawrie, and L Watkins, and R A Winkle, and M M Mower, and A C Thomas, and S Nisam
August 1986, The Annals of thoracic surgery,
R B Shepard, and M D Goldin, and G M Lawrie, and L Watkins, and R A Winkle, and M M Mower, and A C Thomas, and S Nisam
November 1990, Journal of the American College of Cardiology,
R B Shepard, and M D Goldin, and G M Lawrie, and L Watkins, and R A Winkle, and M M Mower, and A C Thomas, and S Nisam
September 1991, Minerva anestesiologica,
R B Shepard, and M D Goldin, and G M Lawrie, and L Watkins, and R A Winkle, and M M Mower, and A C Thomas, and S Nisam
April 1990, Herz,
Copied contents to your clipboard!