Measurement of whole blood phagocyte chemiluminescence in a microtitreplate format. 1992

S S Lee
Medical A Unit, Queen Elizabeth Hospital, Kowloon, Hong Kong.

Zymosan-induced luminol-enhanced chemiluminescence of phagocytes was measured in whole blood using a microtitreplate format. A consistent reaction response curve could be obtained using a normal blood sample, with low intra-assay variations in peak light index, cumulated response as well as time taken to reach the peak. Variations were common when tests were done on different days for the same individual, or when different persons were compared simultaneously. Reactions were hastened and enhanced if continuous shaking at 37 degrees C was applied. The interval between time zero and peak was the most consistent variable, with a coefficient of variation of 12% in inter-assay analysis. Because of its simplicity and ease of operation, the method is potentially useful in studying phagocyte functions in pathological states.

UI MeSH Term Description Entries
D008163 Luminescent Measurements Techniques used for determining the values of photometric parameters of light resulting from LUMINESCENCE. Bioluminescence Measurements,Bioluminescent Assays,Bioluminescent Measurements,Chemiluminescence Measurements,Chemiluminescent Assays,Chemiluminescent Measurements,Chemoluminescence Measurements,Luminescence Measurements,Luminescent Assays,Luminescent Techniques,Phosphorescence Measurements,Phosphorescent Assays,Phosphorescent Measurements,Assay, Bioluminescent,Assay, Chemiluminescent,Assay, Luminescent,Assay, Phosphorescent,Assays, Bioluminescent,Assays, Chemiluminescent,Assays, Luminescent,Assays, Phosphorescent,Bioluminescence Measurement,Bioluminescent Assay,Bioluminescent Measurement,Chemiluminescence Measurement,Chemiluminescent Assay,Chemiluminescent Measurement,Chemoluminescence Measurement,Luminescence Measurement,Luminescent Assay,Luminescent Measurement,Luminescent Technique,Measurement, Bioluminescence,Measurement, Bioluminescent,Measurement, Chemiluminescence,Measurement, Chemiluminescent,Measurement, Chemoluminescence,Measurement, Luminescence,Measurement, Luminescent,Measurement, Phosphorescence,Measurement, Phosphorescent,Measurements, Bioluminescence,Measurements, Bioluminescent,Measurements, Chemiluminescence,Measurements, Chemiluminescent,Measurements, Chemoluminescence,Measurements, Luminescence,Measurements, Luminescent,Measurements, Phosphorescence,Measurements, Phosphorescent,Phosphorescence Measurement,Phosphorescent Assay,Phosphorescent Measurement,Technique, Luminescent,Techniques, Luminescent
D008165 Luminol 5-Amino-2,3-dihydro-1,4-phthalazinedione. Substance that emits light on oxidation. It is used in chemical determinations.
D010586 Phagocytes Cells that can carry out the process of PHAGOCYTOSIS. Phagocyte,Phagocytic Cell,Phagocytic Cells,Cell, Phagocytic,Cells, Phagocytic
D012016 Reference Values The range or frequency distribution of a measurement in a population (of organisms, organs or things) that has not been selected for the presence of disease or abnormality. Normal Range,Normal Values,Reference Ranges,Normal Ranges,Normal Value,Range, Normal,Range, Reference,Ranges, Normal,Ranges, Reference,Reference Range,Reference Value,Value, Normal,Value, Reference,Values, Normal,Values, Reference
D006403 Hematologic Tests Tests used in the analysis of the hemic system. Blood Tests,Hematologic Test,Hematological Tests,Test, Hematologic,Tests, Hematologic,Blood Test,Hematological Test,Test, Blood,Test, Hematological,Tests, Blood,Tests, Hematological
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D015054 Zymosan Zymosan A
D015203 Reproducibility of Results The statistical reproducibility of measurements (often in a clinical context), including the testing of instrumentation or techniques to obtain reproducible results. The concept includes reproducibility of physiological measurements, which may be used to develop rules to assess probability or prognosis, or response to a stimulus; reproducibility of occurrence of a condition; and reproducibility of experimental results. Reliability and Validity,Reliability of Result,Reproducibility Of Result,Reproducibility of Finding,Validity of Result,Validity of Results,Face Validity,Reliability (Epidemiology),Reliability of Results,Reproducibility of Findings,Test-Retest Reliability,Validity (Epidemiology),Finding Reproducibilities,Finding Reproducibility,Of Result, Reproducibility,Of Results, Reproducibility,Reliabilities, Test-Retest,Reliability, Test-Retest,Result Reliabilities,Result Reliability,Result Validities,Result Validity,Result, Reproducibility Of,Results, Reproducibility Of,Test Retest Reliability,Validity and Reliability,Validity, Face

Related Publications

S S Lee
September 1988, Journal of immunological methods,
S S Lee
January 1997, Journal of bioluminescence and chemiluminescence,
S S Lee
May 1983, Journal of immunological methods,
S S Lee
January 1989, Journal of bioluminescence and chemiluminescence,
S S Lee
January 1998, Methods in molecular biology (Clifton, N.J.),
S S Lee
January 2013, Luminescence : the journal of biological and chemical luminescence,
S S Lee
January 1998, Methods in molecular biology (Clifton, N.J.),
Copied contents to your clipboard!