Miniature endoscope for simultaneous optical coherence tomography and laser-induced fluorescence measurement. 2004

Alexandre R Tumlinson, and Lida P Hariri, and Urs Utzinger, and Jennifer K Barton
University of Arizona, 1230 East Speedway Boulevard, Tucson, Arizona 85721-0104, USA.

We have designed a multimodality system that combines optical coherence tomography (OCT) and laser-induced fluorescence (LIF) in a 2.0-mm-diameter endoscopic package. OCT provides approximately 18-microm resolution cross-sectional structural information over a 6-mm field. LIF spectra are collected sequentially at submillimeter resolution across the same field and provide histochemical information about the tissue. We present the use of a rod prism to reduce the asymmetry in the OCT beam caused by a cylindrical window. The endoscope has been applied to investigate mouse colon cancer in vivo.

UI MeSH Term Description Entries
D007834 Lasers An optical source that emits photons in a coherent beam. Light Amplification by Stimulated Emission of Radiation (LASER) is brought about using devices that transform light of varying frequencies into a single intense, nearly nondivergent beam of monochromatic radiation. Lasers operate in the infrared, visible, ultraviolet, or X-ray regions of the spectrum. Masers,Continuous Wave Lasers,Pulsed Lasers,Q-Switched Lasers,Continuous Wave Laser,Laser,Laser, Continuous Wave,Laser, Pulsed,Laser, Q-Switched,Lasers, Continuous Wave,Lasers, Pulsed,Lasers, Q-Switched,Maser,Pulsed Laser,Q Switched Lasers,Q-Switched Laser
D003113 Colonoscopy Endoscopic examination, therapy or surgery of the luminal surface of the colon. Colonoscopic Surgical Procedures,Surgical Procedures, Colonoscopic,Colonoscopic Surgery,Surgery, Colonoscopic,Colonoscopic Surgeries,Colonoscopic Surgical Procedure,Colonoscopies,Procedure, Colonoscopic Surgical,Procedures, Colonoscopic Surgical,Surgeries, Colonoscopic,Surgical Procedure, Colonoscopic
D004396 Coloring Agents Chemicals and substances that impart color including soluble dyes and insoluble pigments. They are used in INKS; PAINTS; and as INDICATORS AND REAGENTS. Coloring Agent,Dye,Dyes,Organic Pigment,Stain,Stains,Tissue Stain,Tissue Stains,Organic Pigments,Pigments, Inorganic,Agent, Coloring,Inorganic Pigments,Pigment, Organic,Pigments, Organic,Stain, Tissue,Stains, Tissue
D004867 Equipment Design Methods and patterns of fabricating machines and related hardware. Design, Equipment,Device Design,Medical Device Design,Design, Medical Device,Designs, Medical Device,Device Design, Medical,Device Designs, Medical,Medical Device Designs,Design, Device,Designs, Device,Designs, Equipment,Device Designs,Equipment Designs
D005453 Fluorescence The property of emitting radiation while being irradiated. The radiation emitted is usually of longer wavelength than that incident or absorbed, e.g., a substance can be irradiated with invisible radiation and emit visible light. X-ray fluorescence is used in diagnosis.
D000818 Animals Unicellular or multicellular, heterotrophic organisms, that have sensation and the power of voluntary movement. Under the older five kingdom paradigm, Animalia was one of the kingdoms. Under the modern three domain model, Animalia represents one of the many groups in the domain EUKARYOTA. Animal,Metazoa,Animalia
D051379 Mice The common name for the genus Mus. Mice, House,Mus,Mus musculus,Mice, Laboratory,Mouse,Mouse, House,Mouse, Laboratory,Mouse, Swiss,Mus domesticus,Mus musculus domesticus,Swiss Mice,House Mice,House Mouse,Laboratory Mice,Laboratory Mouse,Mice, Swiss,Swiss Mouse,domesticus, Mus musculus
D019723 Endoscopes Instruments for the visual examination of interior structures of the body. There are rigid endoscopes and flexible fiberoptic endoscopes for various types of viewing in ENDOSCOPY. Endoscope
D020685 Colonoscopes Specially designed endoscopes for visualizing the interior surface of the colon. Colonoscope
D041623 Tomography, Optical Coherence An imaging method using LASERS that is used for mapping subsurface structure. When a reflective site in the sample is at the same optical path length (coherence) as the reference mirror, the detector observes interference fringes. OCT Tomography,Optical Coherence Tomography,Coherence Tomography, Optical,Tomography, OCT

Related Publications

Alexandre R Tumlinson, and Lida P Hariri, and Urs Utzinger, and Jennifer K Barton
August 2004, Optics letters,
Alexandre R Tumlinson, and Lida P Hariri, and Urs Utzinger, and Jennifer K Barton
September 2010, Cancer biology & therapy,
Alexandre R Tumlinson, and Lida P Hariri, and Urs Utzinger, and Jennifer K Barton
August 2012, Journal of biomedical optics,
Alexandre R Tumlinson, and Lida P Hariri, and Urs Utzinger, and Jennifer K Barton
January 2004, Journal of biomedical optics,
Alexandre R Tumlinson, and Lida P Hariri, and Urs Utzinger, and Jennifer K Barton
August 2015, Applied optics,
Alexandre R Tumlinson, and Lida P Hariri, and Urs Utzinger, and Jennifer K Barton
January 2013, Biomedical optics express,
Alexandre R Tumlinson, and Lida P Hariri, and Urs Utzinger, and Jennifer K Barton
June 2019, Physics in medicine and biology,
Alexandre R Tumlinson, and Lida P Hariri, and Urs Utzinger, and Jennifer K Barton
January 2015, Biomedical optics express,
Alexandre R Tumlinson, and Lida P Hariri, and Urs Utzinger, and Jennifer K Barton
February 2015, Optics express,
Alexandre R Tumlinson, and Lida P Hariri, and Urs Utzinger, and Jennifer K Barton
January 2010, Physics in medicine and biology,
Copied contents to your clipboard!