The transoocyte voltage clamp: a non-invasive technique for electrophysiological experiments with Xenopus laevis oocytes. 2004

Dana Cucu, and Jeannine Simaels, and Danny Jans, and Willy Van Driessche
Laboratory of Physiology, KU Leuven, Campus Gasthuisberg O/N, 3000 Leuven, Belgium.

We developed a non-invasive technique for electrophysiological investigations of ion transport proteins endogenously or heterologously expressed in Xenopus laevis oocytes. We named this technique the transoocyte voltage clamp (TOVC). Whereas in the classical two-microelectrode voltage-clamp (TEVC) technique, the oocyte is impaled with two glass microelectrodes, we mount the egg in a modified Ussing chamber as used for transepithelial electrophysiological studies. The oocyte is introduced in a container that is positioned between the two chamber halves. Proper fixation of the oocyte in the aperture of the container is accomplished under a stereo binocular microscope and the electrical seal between the oocyte and the container is achieved with silicon grease. The new method allows measurement of transoocyte currents and conductances as well as the recording of membrane impedance and the fluctuation analysis of ion currents. We studied a K+ channel that resembles the inward rectifier K+ channel endogenously expressed in Xenopus laevis oocytes. K+ currents were obtained by exposing one side of the oocyte to K(+)-containing solutions and by the application of different voltages. Adding Cs+ and Ba2+ inhibited these currents. The analysis of the fluctuation in current demonstrated a Lorentzian component in the power density spectrum. With the transoocyte voltage clamped to zero, the corner frequency (fc) was 61+/-1.7 Hz. Imposed positive transoocyte potentials caused a downward shift of fc. These findings are consistent with previous data obtained using the TEVC technique, and extend the characterization of the channel with kinetic data obtained from noise analysis.

UI MeSH Term Description Entries
D009865 Oocytes Female germ cells derived from OOGONIA and termed OOCYTES when they enter MEIOSIS. The primary oocytes begin meiosis but are arrested at the diplotene state until OVULATION at PUBERTY to give rise to haploid secondary oocytes or ova (OVUM). Ovocytes,Oocyte,Ovocyte
D004594 Electrophysiology The study of the generation and behavior of electrical charges in living organisms particularly the nervous system and the effects of electricity on living organisms.
D005260 Female Females
D000818 Animals Unicellular or multicellular, heterotrophic organisms, that have sensation and the power of voluntary movement. Under the older five kingdom paradigm, Animalia was one of the kingdoms. Under the modern three domain model, Animalia represents one of the many groups in the domain EUKARYOTA. Animal,Metazoa,Animalia
D014982 Xenopus laevis The commonest and widest ranging species of the clawed "frog" (Xenopus) in Africa. This species is used extensively in research. There is now a significant population in California derived from escaped laboratory animals. Platanna,X. laevis,Platannas,X. laevi
D015221 Potassium Channels Cell membrane glycoproteins that are selectively permeable to potassium ions. At least eight major groups of K channels exist and they are made up of dozens of different subunits. Ion Channels, Potassium,Ion Channel, Potassium,Potassium Channel,Potassium Ion Channels,Channel, Potassium,Channel, Potassium Ion,Channels, Potassium,Channels, Potassium Ion,Potassium Ion Channel
D015640 Ion Channel Gating The opening and closing of ion channels due to a stimulus. The stimulus can be a change in membrane potential (voltage-gated), drugs or chemical transmitters (ligand-gated), or a mechanical deformation. Gating is thought to involve conformational changes of the ion channel which alters selective permeability. Gating, Ion Channel,Gatings, Ion Channel,Ion Channel Gatings
D018408 Patch-Clamp Techniques An electrophysiologic technique for studying cells, cell membranes, and occasionally isolated organelles. All patch-clamp methods rely on a very high-resistance seal between a micropipette and a membrane; the seal is usually attained by gentle suction. The four most common variants include on-cell patch, inside-out patch, outside-out patch, and whole-cell clamp. Patch-clamp methods are commonly used to voltage clamp, that is control the voltage across the membrane and measure current flow, but current-clamp methods, in which the current is controlled and the voltage is measured, are also used. Patch Clamp Technique,Patch-Clamp Technic,Patch-Clamp Technique,Voltage-Clamp Technic,Voltage-Clamp Technique,Voltage-Clamp Techniques,Whole-Cell Recording,Patch-Clamp Technics,Voltage-Clamp Technics,Clamp Technique, Patch,Clamp Techniques, Patch,Patch Clamp Technic,Patch Clamp Technics,Patch Clamp Techniques,Recording, Whole-Cell,Recordings, Whole-Cell,Technic, Patch-Clamp,Technic, Voltage-Clamp,Technics, Patch-Clamp,Technics, Voltage-Clamp,Technique, Patch Clamp,Technique, Patch-Clamp,Technique, Voltage-Clamp,Techniques, Patch Clamp,Techniques, Patch-Clamp,Techniques, Voltage-Clamp,Voltage Clamp Technic,Voltage Clamp Technics,Voltage Clamp Technique,Voltage Clamp Techniques,Whole Cell Recording,Whole-Cell Recordings
D066298 In Vitro Techniques Methods to study reactions or processes taking place in an artificial environment outside the living organism. In Vitro Test,In Vitro Testing,In Vitro Tests,In Vitro as Topic,In Vitro,In Vitro Technique,In Vitro Testings,Technique, In Vitro,Techniques, In Vitro,Test, In Vitro,Testing, In Vitro,Testings, In Vitro,Tests, In Vitro,Vitro Testing, In

Related Publications

Dana Cucu, and Jeannine Simaels, and Danny Jans, and Willy Van Driessche
October 1983, Pflugers Archiv : European journal of physiology,
Dana Cucu, and Jeannine Simaels, and Danny Jans, and Willy Van Driessche
July 1991, Journal of neuroscience methods,
Dana Cucu, and Jeannine Simaels, and Danny Jans, and Willy Van Driessche
May 2001, Current protocols in neuroscience,
Dana Cucu, and Jeannine Simaels, and Danny Jans, and Willy Van Driessche
June 2007, Biosensors & bioelectronics,
Dana Cucu, and Jeannine Simaels, and Danny Jans, and Willy Van Driessche
January 1962, The Journal of physiology,
Dana Cucu, and Jeannine Simaels, and Danny Jans, and Willy Van Driessche
January 2022, Methods in molecular biology (Clifton, N.J.),
Dana Cucu, and Jeannine Simaels, and Danny Jans, and Willy Van Driessche
October 1959, The Journal of physiology,
Dana Cucu, and Jeannine Simaels, and Danny Jans, and Willy Van Driessche
June 1989, The Journal of physiology,
Dana Cucu, and Jeannine Simaels, and Danny Jans, and Willy Van Driessche
November 1963, The Journal of physiology,
Dana Cucu, and Jeannine Simaels, and Danny Jans, and Willy Van Driessche
January 1991, Methods in cell biology,
Copied contents to your clipboard!