Optimal pacing for symptomatic AV block: a comparison of VDD and DDD pacing. 2004

Max Huang, and Andrew D Krahn, and Raymond Yee, and George J Klein, and Allan C Skanes
Division of Cardiology, University of Western Ontario, London, Ontario, Canada.

VDD pacing provides the physiological benefits of atrioventricular synchronous pacing with the convenience of a single lead system, but is hampered by uncertainty regarding long term atrial sensing and potential development of sinus node disease. To examine the long-term reliability and complication rates of VDD pacing, we compared the outcome of 112 consecutive patients (age 70 +/- 13 years, 59% men) with symptomatic AV block who received a single pass bipolar VDD system, to 80 patients (age 63 +/- 16 years, 70% men) who received DDD pacing for the same indication. All patients were judged to have intact sinus node function based on submitted ECGs and monitoring results at the time of implant. Implant time was reduced in VDD patients compared to DDD patients (63 +/- 20 vs 97 +/- 36 minutes, P < 0.0001). Implant complications occurred in 5 (6%) DDD patients compared to 3 (3%) VDD patients (P = 0.15). The implant P wave was lower with VDD pacing compared to DDD patients (2.91 +/- 1.48 vs 4.0 +/- 1.7 mv, P < 0.0001), but remained stable during long-term follow-up in both groups. During 17.7 +/- 10.0 months of follow-up in the VDD group, only two VDD patients were reprogrammed to VVIR mode, compared to three DDD patients. Physiological atrioventricular activation was maintained in 94%-99% of beats throughout the follow-up period in the VDD group. VDD pacing is an excellent strategy for treatment of patients with symptomatic AV block. The lower cost, high reliability, and abbreviated implantation time suggest that VDD pacing is a viable alternative to DDD pacing in patients with high degree AV block and normal sinus node function.

UI MeSH Term Description Entries
D008297 Male Males
D008875 Middle Aged An adult aged 45 - 64 years. Middle Age
D010138 Pacemaker, Artificial A device designed to stimulate, by electric impulses, contraction of the heart muscles. It may be temporary (external) or permanent (internal or internal-external). Cardiac Pacemaker, Artificial,Artificial Cardiac Pacemaker,Artificial Cardiac Pacemakers,Artificial Pacemaker,Artificial Pacemakers,Cardiac Pacemakers, Artificial,Pacemaker, Artificial Cardiac,Pacemakers, Artificial,Pacemakers, Artificial Cardiac
D002304 Cardiac Pacing, Artificial Regulation of the rate of contraction of the heart muscles by an artificial pacemaker. Pacing, Cardiac, Artificial,Artificial Cardiac Pacing,Artificial Cardiac Pacings,Cardiac Pacings, Artificial,Pacing, Artificial Cardiac,Pacings, Artificial Cardiac
D005260 Female Females
D006327 Heart Block Impaired conduction of cardiac impulse that can occur anywhere along the conduction pathway, such as between the SINOATRIAL NODE and the right atrium (SA block) or between atria and ventricles (AV block). Heart blocks can be classified by the duration, frequency, or completeness of conduction block. Reversibility depends on the degree of structural or functional defects. Auriculo-Ventricular Dissociation,A-V Dissociation,Atrioventricular Dissociation,A V Dissociation,A-V Dissociations,Atrioventricular Dissociations,Auriculo Ventricular Dissociation,Auriculo-Ventricular Dissociations,Block, Heart,Blocks, Heart,Dissociation, A-V,Dissociation, Atrioventricular,Dissociation, Auriculo-Ventricular,Dissociations, A-V,Dissociations, Atrioventricular,Dissociations, Auriculo-Ventricular,Heart Blocks
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D000368 Aged A person 65 years of age or older. For a person older than 79 years, AGED, 80 AND OVER is available. Elderly
D012189 Retrospective Studies Studies used to test etiologic hypotheses in which inferences about an exposure to putative causal factors are derived from data relating to characteristics of persons under study or to events or experiences in their past. The essential feature is that some of the persons under study have the disease or outcome of interest and their characteristics are compared with those of unaffected persons. Retrospective Study,Studies, Retrospective,Study, Retrospective

Related Publications

Max Huang, and Andrew D Krahn, and Raymond Yee, and George J Klein, and Allan C Skanes
January 2000, Wiener medizinische Wochenschrift (1946),
Max Huang, and Andrew D Krahn, and Raymond Yee, and George J Klein, and Allan C Skanes
September 2000, Pacing and clinical electrophysiology : PACE,
Max Huang, and Andrew D Krahn, and Raymond Yee, and George J Klein, and Allan C Skanes
April 2012, Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology,
Max Huang, and Andrew D Krahn, and Raymond Yee, and George J Klein, and Allan C Skanes
August 2016, Medicine,
Max Huang, and Andrew D Krahn, and Raymond Yee, and George J Klein, and Allan C Skanes
October 2001, Italian heart journal : official journal of the Italian Federation of Cardiology,
Max Huang, and Andrew D Krahn, and Raymond Yee, and George J Klein, and Allan C Skanes
October 1999, Pacing and clinical electrophysiology : PACE,
Max Huang, and Andrew D Krahn, and Raymond Yee, and George J Klein, and Allan C Skanes
November 1992, Pacing and clinical electrophysiology : PACE,
Max Huang, and Andrew D Krahn, and Raymond Yee, and George J Klein, and Allan C Skanes
June 1996, The Canadian journal of cardiology,
Max Huang, and Andrew D Krahn, and Raymond Yee, and George J Klein, and Allan C Skanes
June 1999, Heart (British Cardiac Society),
Max Huang, and Andrew D Krahn, and Raymond Yee, and George J Klein, and Allan C Skanes
June 1998, Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing,
Copied contents to your clipboard!