Neutron spectrometry in mixed fields: superheated drop (bubble) detectors. 2003

F d'Errico, and M Matzke
Department of Therapeutic Radiology, Yale University, New Haven, CT, USA.

The BINS neutron threshold spectrometer permits the analysis of the main features of a neutron field for radiation protection purposes. The system offers a virtually complete photon discrimination and nested threshold responses to neutrons, which allow the use of very effective 'few-channel' unfolding procedures. To date, the practical operating energy range of a BINS is 0.1-10 MeV, over which a resolving power of 20-30% can be expected when the deconvolution is performed without explicit pre-information. Spectrum unfolding results in relatively high uncertainties on the differential fluence distributions, but due to negative correlations in adjacent energy groups the uncertainties on integral quantities such as dose equivalent are small and of the order of 5% to 10%, similar to the results of other active spectrometers. In comparison with most radiation detectors, the BINS is an extremely slow system due to the intrinsic duration of a bubble pulse and to the time associated with pulse analysis. For example, the maximum sustainable fluence rate of 1 MeV neutrons is about 10(4) cm(-2) s(-1), which is low for many neutron physics experiments. However, this rate corresponds to an ambient dose equivalent rate of about 1 mSv h(-1), making the active device adequate for radiation protection applications in the workplaces described in Section 1. There are ample margins for improvement of the spectrometer. In particular, in the low-energy region a thermal-epithermal neutron group may be added by using chlorine-bearing emulsions stabilised at suitable temperatures. In fact, the latest version of the system achieves this goal by using a single superheated emulsion of dichlorotetrafluoroethane (R-114) operated at temperatures up to 55 degrees C. This extends the range of the spectrometer and at the same time removes the undue enhancement of the UNFANA output in the low energy region. Above 10 MeV, the resolution can be improved by adding more thresholds, e.g. by starting from a lower initial temperature and using finer temperature increments. Based on neutron kinematics, the theoretical upper energy threshold which can be generated with superheated emulsions is greater than 100 MeV. However, this would most likely require refrigerating the detectors, while the current simpler approach is to operate the detectors at incremental temperature steps starting from the ambient temperature. A range that should be easily achieved in practice is from thermal energies to 20 MeV.

UI MeSH Term Description Entries
D009502 Neutrons Electrically neutral elementary particles found in all atomic nuclei except light hydrogen; the mass is equal to that of the proton and electron combined and they are unstable when isolated from the nucleus, undergoing beta decay. Slow, thermal, epithermal, and fast neutrons refer to the energy levels with which the neutrons are ejected from heavier nuclei during their decay. Neutron
D011829 Radiation Dosage The amount of radiation energy that is deposited in a unit mass of material, such as tissues of plants or animal. In RADIOTHERAPY, radiation dosage is expressed in gray units (Gy). In RADIOLOGIC HEALTH, the dosage is expressed by the product of absorbed dose (Gy) and quality factor (a function of linear energy transfer), and is called radiation dose equivalent in sievert units (Sv). Sievert Units,Dosage, Radiation,Gray Units,Gy Radiation,Sv Radiation Dose Equivalent,Dosages, Radiation,Radiation Dosages,Units, Gray,Units, Sievert
D011835 Radiation Protection Methods and practices adopted to protect against RADIATION. Protection, Radiation
D011874 Radiometry The measurement of radiation by photography, as in x-ray film and film badge, by Geiger-Mueller tube, and by SCINTILLATION COUNTING. Geiger-Mueller Counters,Nuclear Track Detection,Radiation Dosimetry,Dosimetry, Radiation,Geiger Counter,Geiger-Mueller Counter Tube,Geiger-Mueller Probe,Geiger-Mueller Tube,Radiation Counter,Counter Tube, Geiger-Mueller,Counter Tubes, Geiger-Mueller,Counter, Geiger,Counter, Radiation,Counters, Geiger,Counters, Geiger-Mueller,Counters, Radiation,Detection, Nuclear Track,Dosimetries, Radiation,Geiger Counters,Geiger Mueller Counter Tube,Geiger Mueller Counters,Geiger Mueller Probe,Geiger Mueller Tube,Geiger-Mueller Counter Tubes,Geiger-Mueller Probes,Geiger-Mueller Tubes,Probe, Geiger-Mueller,Probes, Geiger-Mueller,Radiation Counters,Radiation Dosimetries,Tube, Geiger-Mueller,Tube, Geiger-Mueller Counter,Tubes, Geiger-Mueller,Tubes, Geiger-Mueller Counter
D002138 Calibration Determination, by measurement or comparison with a standard, of the correct value of each scale reading on a meter or other measuring instrument; or determination of the settings of a control device that correspond to particular values of voltage, current, frequency or other output. Calibrations
D004784 Environmental Monitoring The monitoring of the level of toxins, chemical pollutants, microbial contaminants, or other harmful substances in the environment (soil, air, and water), workplace, or in the bodies of people and animals present in that environment. Monitoring, Environmental,Environmental Surveillance,Surveillance, Environmental
D004867 Equipment Design Methods and patterns of fabricating machines and related hardware. Design, Equipment,Device Design,Medical Device Design,Design, Medical Device,Designs, Medical Device,Device Design, Medical,Device Designs, Medical,Medical Device Designs,Design, Device,Designs, Device,Designs, Equipment,Device Designs,Equipment Designs
D005060 Europe The continent north of AFRICA, west of ASIA and east of the ATLANTIC OCEAN. Northern Europe,Southern Europe,Western Europe
D013057 Spectrum Analysis The measurement of the amplitude of the components of a complex waveform throughout the frequency range of the waveform. (McGraw-Hill Dictionary of Scientific and Technical Terms, 6th ed) Spectroscopy,Analysis, Spectrum,Spectrometry
D013673 Technology Assessment, Biomedical Evaluation of biomedical technology in relation to cost, efficacy, utilization, etc., and its future impact on social, ethical, and legal systems. Assessment, Biomedical Technology,Assessment, Technology,Biomedical Technology Assessment,Technology Assessment,Technology Assessment, Health,Assessment, Health Technology,Assessments, Biomedical Technology,Assessments, Health Technology,Assessments, Technology,Biomedical Technology Assessments,Health Technology Assessment,Health Technology Assessments,Technology Assessments,Technology Assessments, Biomedical,Technology Assessments, Health

Related Publications

F d'Errico, and M Matzke
January 2002, Radiation protection dosimetry,
F d'Errico, and M Matzke
January 2006, Radiation protection dosimetry,
F d'Errico, and M Matzke
January 2006, Radiation protection dosimetry,
F d'Errico, and M Matzke
January 2001, Radiation protection dosimetry,
F d'Errico, and M Matzke
January 2002, Radiation protection dosimetry,
F d'Errico, and M Matzke
January 2007, Radiation protection dosimetry,
F d'Errico, and M Matzke
January 2008, Radiation protection dosimetry,
F d'Errico, and M Matzke
January 2005, Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine,
F d'Errico, and M Matzke
January 2003, Radiation protection dosimetry,
F d'Errico, and M Matzke
January 2005, Radiation protection dosimetry,
Copied contents to your clipboard!