Ambulatory oxygen uptake measurement system. 1992

T Tamura, and K Sato, and T Togawa
Department of Electrical and Electronic Engineering, Yamaguchi University, Japan.

An apparatus for monitoring prolonged measurement of oxygen uptake without discomfort has been developed. The system is based on the open flow-through principle. The subject wears a hood through which air is drawn by an exhaust blower. Oxygen concentration is kept constant by a servo-controlled blower, so that flow rate is essentially proportional to oxygen uptake. The flow rate of the main stream is measured by a time-of-flight flowmeter located in the exhaust hose. Oxygen concentration is measured by a limiting-current oxygen sensor. The signals representing flow rate and oxygen concentration are digitized and stored in a memory. All of the equipment is assembled in a small package (wt = 3 kg) which the subject carries on his back. The memory chip is removed from the portable device after each experiment. Data are transferred from the memory to a microcomputer and then an oxygen uptake trend is estimated. Response of the system to a step input is about 30 s. Compared with a commercially available oxygen monitoring system (Magna 88, P. K. Morgan Ltd., Rainham, UK), the maximum difference was 0.15 L/min within an oxygen uptake range of 0.25-2.3 L/min. Thus, the measurements made with our portable device agree with the results obtained using the conventional method.

UI MeSH Term Description Entries
D008297 Male Males
D008433 Mathematics The deductive study of shape, quantity, and dependence. (From McGraw-Hill Dictionary of Scientific and Technical Terms, 6th ed) Mathematic
D008838 Microcomputers Small computers using LSI (large-scale integration) microprocessor chips as the CPU (central processing unit) and semiconductor memories for compact, inexpensive storage of program instructions and data. They are smaller and less expensive than minicomputers and are usually built into a dedicated system where they are optimized for a particular application. "Microprocessor" may refer to just the CPU or the entire microcomputer. Computers, Personal,Microprocessors,Computer, Personal,Microcomputer,Microprocessor,Personal Computer,Personal Computers
D008991 Monitoring, Physiologic The continuous measurement of physiological processes, blood pressure, heart rate, renal output, reflexes, respiration, etc., in a patient or experimental animal; includes pharmacologic monitoring, the measurement of administered drugs or their metabolites in the blood, tissues, or urine. Patient Monitoring,Monitoring, Physiological,Physiologic Monitoring,Monitoring, Patient,Physiological Monitoring
D010100 Oxygen An element with atomic symbol O, atomic number 8, and atomic weight [15.99903; 15.99977]. It is the most abundant element on earth and essential for respiration. Dioxygen,Oxygen-16,Oxygen 16
D010101 Oxygen Consumption The rate at which oxygen is used by a tissue; microliters of oxygen STPD used per milligram of tissue per hour; the rate at which oxygen enters the blood from alveolar gas, equal in the steady state to the consumption of oxygen by tissue metabolism throughout the body. (Stedman, 25th ed, p346) Consumption, Oxygen,Consumptions, Oxygen,Oxygen Consumptions
D002138 Calibration Determination, by measurement or comparison with a standard, of the correct value of each scale reading on a meter or other measuring instrument; or determination of the settings of a control device that correspond to particular values of voltage, current, frequency or other output. Calibrations
D004867 Equipment Design Methods and patterns of fabricating machines and related hardware. Design, Equipment,Device Design,Medical Device Design,Design, Medical Device,Designs, Medical Device,Device Design, Medical,Device Designs, Medical,Medical Device Designs,Design, Device,Designs, Device,Designs, Equipment,Device Designs,Equipment Designs
D005069 Evaluation Studies as Topic Works about studies that determine the effectiveness or value of processes, personnel, and equipment, or the material on conducting such studies. Critique,Evaluation Indexes,Evaluation Methodology,Evaluation Report,Evaluation Research,Methodology, Evaluation,Pre-Post Tests,Qualitative Evaluation,Quantitative Evaluation,Theoretical Effectiveness,Use-Effectiveness,Critiques,Effectiveness, Theoretical,Evaluation Methodologies,Evaluation Reports,Evaluation, Qualitative,Evaluation, Quantitative,Evaluations, Qualitative,Evaluations, Quantitative,Indexes, Evaluation,Methodologies, Evaluation,Pre Post Tests,Pre-Post Test,Qualitative Evaluations,Quantitative Evaluations,Report, Evaluation,Reports, Evaluation,Research, Evaluation,Test, Pre-Post,Tests, Pre-Post,Use Effectiveness
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man

Related Publications

T Tamura, and K Sato, and T Togawa
July 1992, Chest,
T Tamura, and K Sato, and T Togawa
August 2004, Gait & posture,
T Tamura, and K Sato, and T Togawa
September 2000, Nihon rinsho. Japanese journal of clinical medicine,
T Tamura, and K Sato, and T Togawa
August 1981, American journal of optometry and physiological optics,
T Tamura, and K Sato, and T Togawa
January 1992, European journal of applied physiology and occupational physiology,
T Tamura, and K Sato, and T Togawa
April 2024, Journal of clinical medicine,
T Tamura, and K Sato, and T Togawa
January 2015, Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference,
T Tamura, and K Sato, and T Togawa
October 1980, Aviation, space, and environmental medicine,
T Tamura, and K Sato, and T Togawa
January 1983, Nihon seirigaku zasshi. Journal of the Physiological Society of Japan,
Copied contents to your clipboard!