Canine pulmonary filtration coefficient calculated from optical, radioisotope, and weight measurements. 1992

N R Harris, and R E Parker, and N A Pou, and R J Roselli
Department of Biomedical Engineering, Vanderbilt University, Nashville 37235.

Three independent methods were used to estimate filtration coefficient (Kf) in isolated dog lungs perfused with low-hematocrit (Hct) blood. Pulmonary vascular pressure was increased by 12-23 cmH2O to induce fluid filtration. Average Kf (ml.min-1 x cmH2O-1 x 100 g dry wt-1) for six lungs was 0.26 +/- 0.05 (SE) with use of equations describing conservation of optically measured protein labeled with indocyanine green. Good agreement was found when a simplified version of the multiequation theory was applied to the data (0.24 +/- 0.05). Both optical estimates were lower than those predicted by constant slope (0.55 +/- 0.07) or extrapolation (1.20 +/- 0.15) techniques, which are based on changes in total lung weight. Subsequent studies in five dog lungs investigated whether the higher Kf from weight analyses could be caused by prolonged pulmonary vascular filling. We found that 51Cr-labeled red blood cells (RBCs), monitored over the lung, continued to accumulate for 30 min after vascular pressure elevations of 9-16 cmH2O.Kf was determined by subtracting computed vascular filling from total weight change (0.28 +/- 0.06) and by perfusate Hct changes determined from radiolabeled RBCs (0.23 +/- 0.04). These values were similar to those obtained from analysis of optical data with the complete model (0.30 +/- 0.06), the simplified version (0.26 +/- 0.05), and from optically determined perfusate Hct (0.16 +/- 0.03). However, constant slope (0.47 +/- 0.04) and extrapolation (0.57 +/- 0.07) computations of Kf were higher than estimates from the other methods. Our studies indicate that prolonged blood volume changes may accompany vascular pressure elevations and produce overestimates of Kf with standard weight measurement techniques. However, Kf computed from optical measurements is independent of pulmonary blood volume changes.

UI MeSH Term Description Entries
D007208 Indocyanine Green A tricarbocyanine dye that is used diagnostically in liver function tests and to determine blood volume and cardiac output. Cardio-Green,Cardiogreen,Ujoveridin,Vofaverdin,Vophaverdin,Wofaverdin,Cardio Green,Green, Indocyanine
D008168 Lung Either of the pair of organs occupying the cavity of the thorax that effect the aeration of the blood. Lungs
D008176 Lung Volume Measurements Measurement of the amount of air that the lungs may contain at various points in the respiratory cycle. Lung Capacities,Lung Volumes,Capacity, Lung,Lung Capacity,Lung Volume,Lung Volume Measurement,Measurement, Lung Volume,Volume, Lung
D008297 Male Males
D008954 Models, Biological Theoretical representations that simulate the behavior or activity of biological processes or diseases. For disease models in living animals, DISEASE MODELS, ANIMAL is available. Biological models include the use of mathematical equations, computers, and other electronic equipment. Biological Model,Biological Models,Model, Biological,Models, Biologic,Biologic Model,Biologic Models,Model, Biologic
D009929 Organ Size The measurement of an organ in volume, mass, or heaviness. Organ Volume,Organ Weight,Size, Organ,Weight, Organ
D010101 Oxygen Consumption The rate at which oxygen is used by a tissue; microliters of oxygen STPD used per milligram of tissue per hour; the rate at which oxygen enters the blood from alveolar gas, equal in the steady state to the consumption of oxygen by tissue metabolism throughout the body. (Stedman, 25th ed, p346) Consumption, Oxygen,Consumptions, Oxygen,Oxygen Consumptions
D011652 Pulmonary Circulation The circulation of the BLOOD through the LUNGS. Pulmonary Blood Flow,Respiratory Circulation,Circulation, Pulmonary,Circulation, Respiratory,Blood Flow, Pulmonary,Flow, Pulmonary Blood,Pulmonary Blood Flows
D001810 Blood Volume Volume of circulating BLOOD. It is the sum of the PLASMA VOLUME and ERYTHROCYTE VOLUME. Blood Volumes,Volume, Blood,Volumes, Blood
D002860 Chromium Radioisotopes Unstable isotopes of chromium that decay or disintegrate emitting radiation. Cr atoms with atomic weights of 46-49, 51, 55, and 56 are radioactive chromium isotopes. Radioisotopes, Chromium

Related Publications

N R Harris, and R E Parker, and N A Pou, and R J Roselli
January 1994, Annals of biomedical engineering,
N R Harris, and R E Parker, and N A Pou, and R J Roselli
January 1998, Annals of biomedical engineering,
N R Harris, and R E Parker, and N A Pou, and R J Roselli
March 1991, The Journal of surgical research,
N R Harris, and R E Parker, and N A Pou, and R J Roselli
August 1980, The American journal of physiology,
N R Harris, and R E Parker, and N A Pou, and R J Roselli
September 1979, Lymphology,
N R Harris, and R E Parker, and N A Pou, and R J Roselli
August 2008, American journal of physiology. Lung cellular and molecular physiology,
N R Harris, and R E Parker, and N A Pou, and R J Roselli
December 1978, Applied optics,
N R Harris, and R E Parker, and N A Pou, and R J Roselli
January 1981, Journal of biomechanics,
N R Harris, and R E Parker, and N A Pou, and R J Roselli
March 1978, The American journal of physiology,
Copied contents to your clipboard!