Emission of phthalates from PVC and other materials. 2004

A Afshari, and L Gunnarsen, and P A Clausen, and V Hansen
Danish Building and Urban Research, PO Box 119, DK-2970 Hørsholm, Denmark. ala@dbur.dk

The main objective of this study was to generate quantitative and qualitative emission data on phthalates from different materials. To achieve this the existing (Chamber for Laboratory Investigations of Materials, Pollution and Air Quality) Climpaq-based procedure for simplified measurements of emissions of plasticizer from PVC and other plasticized materials was modified. It was applied to a range of products. Some of them were suspected of contributing to the indoor concentration of plasticizers. The emissions from PVC flooring, polyolefine flooring, a refrigerator list, two electric cables, PVC skirting and floor wax were studied in separate Climpaqs. The emission from the PVC flooring in the Climpaq was compared with results from the ultra-small chamber Field and Laboratory Emission Cell (FLEC). Sampling and analysis methods were optimized to measure plasticizers. Samples were taken in exhaust air from the chambers after 6, 35, 62, 105, and 150 days from the start of the experiment. PVC flooring was tested for an additional 100 days. Polyolefine covered with wax resulted in an air concentration of 22 microg/m3 of dibutylphthalate (DBP), which is two orders of magnitude larger than any other materials, but did not emit di(2-ethylhexyl)phthalate (DEHP). The other materials resulted in max concentration of approximately 1 microg/m3 of DEHP and low emissions of DBP. The concentration of DEHP in each chamber increased slowly to a rather stable level which was reached after 150 days. DBP concentrations in the chambers with PVC skirting, PVC flooring, polyolefine and floor wax reached their quasi-static equilibrium after 60 days. The modified method did not create sufficient data for the calculation of emission rates. Adsorption of emission on chamber surfaces made it impossible to use the first part of the experiment for emission rate calculation. When the concentration had stabilized, it was found to be almost identical and independent of chamber and ventilation rate. Emission rates were reduced at high concentrations probably because the concentration in the material was near equilibrium with the concentration in the chamber air.

UI MeSH Term Description Entries
D008422 Materials Testing The testing of materials and devices, especially those used for PROSTHESES AND IMPLANTS; SUTURES; TISSUE ADHESIVES; etc., for hardness, strength, durability, safety, efficacy, and biocompatibility. Biocompatibility Testing,Biocompatible Materials Testing,Hemocompatibility Testing,Testing, Biocompatible Materials,Testing, Hemocompatible Materials,Hemocompatibility Testings,Hemocompatible Materials Testing,Materials Testing, Biocompatible,Materials Testing, Hemocompatible,Testing, Biocompatibility,Testing, Hemocompatibility,Testing, Materials,Testings, Biocompatibility
D010795 Phthalic Acids A group of compounds that has the general structure of a dicarboxylic acid-substituted benzene ring. The ortho-isomer is used in dye manufacture. (Dorland, 28th ed) Acids, Phthalic
D010968 Plasticizers Materials incorporated mechanically in plastics (usually PVC) to increase flexibility, workability or distensibility; due to the non-chemical inclusion, plasticizers leach out from the plastic and are found in body fluids and the general environment. Plasticizer
D011143 Polyvinyl Chloride A polyvinyl resin used extensively in the manufacture of plastics, including medical devices, tubing, and other packaging. It is also used as a rubber substitute. Chloroethylene Polymer,Polychloroethylene,Vinyl Chloride Polymer,Chloroethylene Homopolymer,Geon,PVC,Ultron,Viaflex,Vinylite,Chloride, Polyvinyl,Homopolymer, Chloroethylene,Polymer, Chloroethylene,Polymer, Vinyl Chloride
D003252 Construction Materials Supplies used in building. Building Materials,Building Material,Construction Material,Material, Building,Material, Construction,Materials, Building,Materials, Construction
D004784 Environmental Monitoring The monitoring of the level of toxins, chemical pollutants, microbial contaminants, or other harmful substances in the environment (soil, air, and water), workplace, or in the bodies of people and animals present in that environment. Monitoring, Environmental,Environmental Surveillance,Surveillance, Environmental
D014691 Ventilation Supplying a building or house, their rooms and corridors, with fresh air. The controlling of the environment thus may be in public or domestic sites and in medical or non-medical locales. (From Dorland, 28th ed) Ventilations
D014835 Volatilization A phase transition from liquid state to gas state, which is affected by Raoult's law. It can be accomplished by fractional distillation. Vaporization,Volatility
D016902 Air Pollution, Indoor The contamination of indoor air. Air Quality, Indoor,Indoor Air Pollution,Indoor Air Quality,Pollution, Indoor Air

Related Publications

A Afshari, and L Gunnarsen, and P A Clausen, and V Hansen
May 1976, Gigiena i sanitariia,
A Afshari, and L Gunnarsen, and P A Clausen, and V Hansen
September 1999, Indoor air,
A Afshari, and L Gunnarsen, and P A Clausen, and V Hansen
June 2002, Food additives and contaminants,
A Afshari, and L Gunnarsen, and P A Clausen, and V Hansen
April 2006, Medical device technology,
A Afshari, and L Gunnarsen, and P A Clausen, and V Hansen
January 2019, Indoor air,
A Afshari, and L Gunnarsen, and P A Clausen, and V Hansen
January 2019, MethodsX,
A Afshari, and L Gunnarsen, and P A Clausen, and V Hansen
January 1998, Bulletin of the Institute of Maritime and Tropical Medicine in Gdynia,
A Afshari, and L Gunnarsen, and P A Clausen, and V Hansen
February 2013, Indoor air,
A Afshari, and L Gunnarsen, and P A Clausen, and V Hansen
January 1967, Journal of dental research,
Copied contents to your clipboard!