Evaluation of "point of care" devices in the measurement of low blood glucose in neonatal practice. 2004

H T Ho, and W K Y Yeung, and B W Y Young
Pamela Youde Nethersole Eastern Hospital, 3 Lok Man Road, Chai Wan, Hong Kong SAR, China. brianyon@netvigator.com

BACKGROUND Low blood glucose in newborns is difficult to detect clinically. Hence a reliable "point of care" device (glucometer) for early detection and treatment of low glucose is needed. OBJECTIVE To evaluate the performance of five readily available glucometers for the detection of low blood glucose in newborn infants. METHODS Glucostix measurements were taken for newborns with risk factors using a Reflolux S (Boehringer) glucometer. If the initial reading was low (< 2.6 mmol/l), further measurements were taken with two other glucometers (phase I, Advantage and Glucotrend (Roche); phase II, Elite XL (Bayer) and Precision (Abbott)), and plasma glucose was measured in the laboratory (Aeroset; Abbott). RESULTS Over 10 months, 101 specimens were collected from 71 newborns (57 in phase I; 44 in phase II). The Advantage glucometer usually overestimated blood glucose with a mean difference of 1.07 mmol/l (p < 0.01) at all low glucose ranges. The Glucotrend, Precision, and Elite XL glucometers performed better; the mean differences were not significantly different from the laboratory measured value (0.17 mmol/l (p = 0.37); -0.12 mmol/l (p = 0.13), and 0.24 mmol/l (p = 0.13) respectively). For detection of glucose concentrations < 2.6 mmol/l, the Precision glucometer had the highest sensitivity (96.4%) and negative predictive value (90%). For lower glucose concentrations (< 2.0 mmol/l), the Glucotrend glucometer performed even better (sensitivity 92.3%, negative predictive value 96.3%). CONCLUSIONS Point of care devices should have good precision in the low glucose concentration range, sensitivity, and accuracy for early detection of neonatal hypoglycaemia. None of the five glucometers was satisfactory as the sole measuring device. The Glucotrend and Precision glucometers have the greatest sensitivity and negative predictive value. However, confirmation with laboratory measurements of plasma glucose and clinical assessment are still of the utmost importance.

UI MeSH Term Description Entries
D007003 Hypoglycemia A syndrome of abnormally low BLOOD GLUCOSE level. Clinical hypoglycemia has diverse etiologies. Severe hypoglycemia eventually lead to glucose deprivation of the CENTRAL NERVOUS SYSTEM resulting in HUNGER; SWEATING; PARESTHESIA; impaired mental function; SEIZURES; COMA; and even DEATH. Fasting Hypoglycemia,Postabsorptive Hypoglycemia,Postprandial Hypoglycemia,Reactive Hypoglycemia,Hypoglycemia, Fasting,Hypoglycemia, Postabsorptive,Hypoglycemia, Postprandial,Hypoglycemia, Reactive
D007231 Infant, Newborn An infant during the first 28 days after birth. Neonate,Newborns,Infants, Newborn,Neonates,Newborn,Newborn Infant,Newborn Infants
D008991 Monitoring, Physiologic The continuous measurement of physiological processes, blood pressure, heart rate, renal output, reflexes, respiration, etc., in a patient or experimental animal; includes pharmacologic monitoring, the measurement of administered drugs or their metabolites in the blood, tissues, or urine. Patient Monitoring,Monitoring, Physiological,Physiologic Monitoring,Monitoring, Patient,Physiological Monitoring
D001786 Blood Glucose Glucose in blood. Blood Sugar,Glucose, Blood,Sugar, Blood
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D012680 Sensitivity and Specificity Binary classification measures to assess test results. Sensitivity or recall rate is the proportion of true positives. Specificity is the probability of correctly determining the absence of a condition. (From Last, Dictionary of Epidemiology, 2d ed) Specificity,Sensitivity,Specificity and Sensitivity
D015997 Neonatal Screening The identification of selected parameters in newborn infants by various tests, examinations, or other procedures. Screening may be performed by clinical or laboratory measures. A screening test is designed to sort out healthy neonates (INFANT, NEWBORN) from those not well, but the screening test is not intended as a diagnostic device, rather instead as epidemiologic. Infant, Newborn, Screening,Newborn Infant Screening,Newborn Screening,Neonatal Screenings,Newborn Infant Screenings,Newborn Screenings,Screening, Neonatal,Screening, Newborn,Screening, Newborn Infant,Screenings, Neonatal,Screenings, Newborn,Screenings, Newborn Infant
D019095 Point-of-Care Systems Laboratory and other services provided to patients at the bedside. These include diagnostic and laboratory testing using automated information entry. Bedside Computing,Point of Care Technology,Bedside Technology,Point-of-Care,Bedside Technologies,Computing, Bedside,Point of Care,Point of Care Systems,Point-of-Care System,Systems, Point-of-Care,Technologies, Bedside,Technology, Bedside

Related Publications

H T Ho, and W K Y Yeung, and B W Y Young
January 2006, Clinical chemistry and laboratory medicine,
H T Ho, and W K Y Yeung, and B W Y Young
June 2023, Critical reviews in clinical laboratory sciences,
H T Ho, and W K Y Yeung, and B W Y Young
September 1997, Archives of disease in childhood. Fetal and neonatal edition,
H T Ho, and W K Y Yeung, and B W Y Young
October 2013, Clinica chimica acta; international journal of clinical chemistry,
H T Ho, and W K Y Yeung, and B W Y Young
May 2013, South African medical journal = Suid-Afrikaanse tydskrif vir geneeskunde,
H T Ho, and W K Y Yeung, and B W Y Young
November 2010, European journal of pediatrics,
H T Ho, and W K Y Yeung, and B W Y Young
December 2007, South African medical journal = Suid-Afrikaanse tydskrif vir geneeskunde,
H T Ho, and W K Y Yeung, and B W Y Young
January 2011, Anesthesia and analgesia,
H T Ho, and W K Y Yeung, and B W Y Young
January 2012, Laboratory animals,
H T Ho, and W K Y Yeung, and B W Y Young
March 2007, Journal of diabetes science and technology,
Copied contents to your clipboard!