High-performance liquid chromatography-electrospray ionization mass spectrometric determination of nisoldipine in human plasma. 2004

Zunjian Zhang, and Yuan Tian, and Li Ni, and Jinheng Li
Center for Instrumental Analysis, China Pharmaceutical University, Nanjing 210009, PR China. zunjianzhang@hotmail.com

A selective and sensitive high-performance liquid chromatography-electrospray ionization mass spectrometry (MS) for the determination of nisoldipine in human plasma is first presented. With nimodipine as the internal standard, nisoldipine is extracted from plasma with ethyl acetate. The organic layer is evaporated and the residue is resuspended in the mobile phase of methanol-water (80:20, v/v). An aliquot of 40 microL is chromatographically analyzed on an Agilent ODS C18 reversed-phase column (5 microm, 250- x 4.6-mm i.d.) by means of selected-ion monitoring mode MS. The calibration curve of nisoldipine in plasma exhibits a linear range from 0.5 to 20.0 ng/mL with a correlation coefficient of 0.9995. The limit of detection is 0.2 ng/mL. The within- and between-day variations (relative standard deviation) are less than 9.28% and 11.13% (n = 5), respectively. The developed method is validated through successful use for the analysis of nisoldipine contained in biological fluids resulting from a phase-I human pharmacokinetic study.

UI MeSH Term Description Entries
D008297 Male Males
D002121 Calcium Channel Blockers A class of drugs that act by selective inhibition of calcium influx through cellular membranes. Calcium Antagonists, Exogenous,Calcium Blockaders, Exogenous,Calcium Channel Antagonist,Calcium Channel Blocker,Calcium Channel Blocking Drug,Calcium Inhibitors, Exogenous,Channel Blockers, Calcium,Exogenous Calcium Blockader,Exogenous Calcium Inhibitor,Calcium Channel Antagonists,Calcium Channel Blocking Drugs,Exogenous Calcium Antagonists,Exogenous Calcium Blockaders,Exogenous Calcium Inhibitors,Antagonist, Calcium Channel,Antagonists, Calcium Channel,Antagonists, Exogenous Calcium,Blockader, Exogenous Calcium,Blocker, Calcium Channel,Blockers, Calcium Channel,Calcium Blockader, Exogenous,Calcium Inhibitor, Exogenous,Channel Antagonist, Calcium,Channel Blocker, Calcium,Inhibitor, Exogenous Calcium
D002138 Calibration Determination, by measurement or comparison with a standard, of the correct value of each scale reading on a meter or other measuring instrument; or determination of the settings of a control device that correspond to particular values of voltage, current, frequency or other output. Calibrations
D002851 Chromatography, High Pressure Liquid Liquid chromatographic techniques which feature high inlet pressures, high sensitivity, and high speed. Chromatography, High Performance Liquid,Chromatography, High Speed Liquid,Chromatography, Liquid, High Pressure,HPLC,High Performance Liquid Chromatography,High-Performance Liquid Chromatography,UPLC,Ultra Performance Liquid Chromatography,Chromatography, High-Performance Liquid,High-Performance Liquid Chromatographies,Liquid Chromatography, High-Performance
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D012680 Sensitivity and Specificity Binary classification measures to assess test results. Sensitivity or recall rate is the proportion of true positives. Specificity is the probability of correctly determining the absence of a condition. (From Last, Dictionary of Epidemiology, 2d ed) Specificity,Sensitivity,Specificity and Sensitivity
D015203 Reproducibility of Results The statistical reproducibility of measurements (often in a clinical context), including the testing of instrumentation or techniques to obtain reproducible results. The concept includes reproducibility of physiological measurements, which may be used to develop rules to assess probability or prognosis, or response to a stimulus; reproducibility of occurrence of a condition; and reproducibility of experimental results. Reliability and Validity,Reliability of Result,Reproducibility Of Result,Reproducibility of Finding,Validity of Result,Validity of Results,Face Validity,Reliability (Epidemiology),Reliability of Results,Reproducibility of Findings,Test-Retest Reliability,Validity (Epidemiology),Finding Reproducibilities,Finding Reproducibility,Of Result, Reproducibility,Of Results, Reproducibility,Reliabilities, Test-Retest,Reliability, Test-Retest,Result Reliabilities,Result Reliability,Result Validities,Result Validity,Result, Reproducibility Of,Results, Reproducibility Of,Test Retest Reliability,Validity and Reliability,Validity, Face
D015737 Nisoldipine A dihydropyridine calcium channel antagonist that acts as a potent arterial vasodilator and antihypertensive agent. It is also effective in patients with cardiac failure and angina. Bay K 5552
D018592 Cross-Over Studies Studies comparing two or more treatments or interventions in which the subjects or patients, upon completion of the course of one treatment, are switched to another. In the case of two treatments, A and B, half the subjects are randomly allocated to receive these in the order A, B and half to receive them in the order B, A. A criticism of this design is that effects of the first treatment may carry over into the period when the second is given. (Last, A Dictionary of Epidemiology, 2d ed) Cross-Over Design,Cross-Over Trials,Crossover Design,Crossover Studies,Crossover Trials,Cross Over Design,Cross Over Studies,Cross Over Trials,Cross-Over Designs,Cross-Over Study,Crossover Designs,Crossover Study,Design, Cross-Over,Design, Crossover,Designs, Cross-Over,Designs, Crossover,Studies, Cross-Over,Studies, Crossover,Study, Cross-Over,Study, Crossover,Trial, Cross-Over,Trial, Crossover,Trials, Cross-Over,Trials, Crossover
D021241 Spectrometry, Mass, Electrospray Ionization A mass spectrometry technique used for analysis of nonvolatile compounds such as proteins and macromolecules. The technique involves preparing electrically charged droplets from analyte molecules dissolved in solvent. The electrically charged droplets enter a vacuum chamber where the solvent is evaporated. Evaporation of solvent reduces the droplet size, thereby increasing the coulombic repulsion within the droplet. As the charged droplets get smaller, the excess charge within them causes them to disintegrate and release analyte molecules. The volatilized analyte molecules are then analyzed by mass spectrometry. ESI Mass Spectrometry,Electrospray Ionization Mass Spectrometry,Mass Spectrometry, ESI,Spectrometry, ESI Mass

Related Publications

Zunjian Zhang, and Yuan Tian, and Li Ni, and Jinheng Li
February 2007, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences,
Zunjian Zhang, and Yuan Tian, and Li Ni, and Jinheng Li
July 2007, Archives of pharmacal research,
Zunjian Zhang, and Yuan Tian, and Li Ni, and Jinheng Li
September 2011, Journal of pharmaceutical and biomedical analysis,
Zunjian Zhang, and Yuan Tian, and Li Ni, and Jinheng Li
July 2008, Biomedical chromatography : BMC,
Zunjian Zhang, and Yuan Tian, and Li Ni, and Jinheng Li
June 2007, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences,
Zunjian Zhang, and Yuan Tian, and Li Ni, and Jinheng Li
January 2001, Yao xue xue bao = Acta pharmaceutica Sinica,
Zunjian Zhang, and Yuan Tian, and Li Ni, and Jinheng Li
January 2003, Rapid communications in mass spectrometry : RCM,
Zunjian Zhang, and Yuan Tian, and Li Ni, and Jinheng Li
October 1999, Journal of chromatography. B, Biomedical sciences and applications,
Zunjian Zhang, and Yuan Tian, and Li Ni, and Jinheng Li
January 2005, Journal of chromatographic science,
Copied contents to your clipboard!