"W-shaped" volume curve with gated myocardial perfusion single photon emission computed tomography. 2005

Tokuo Kasai, and E Gordon DePuey, and Irwin Sponder
Division of Nuclear Medicine, Department of Radiology, St. Luke's-Roosevelt Hospital Center, Columbia University College of Physicians and Surgeons, New York, USA. tkkasai@jikei.ac.jp

OBJECTIVE Gating errors (GEs) with ECG gated myocardial SPECT (G-SPECT) may occur irrespective of the presence or absence of arrhythmias. We evaluated the impact of GEs on both reconstructed tomograms and left ventricular ejection fraction (LVEF) derived from G-SPECT, and searched for clues to identify these errors. METHODS We studied 2 GE patients, 10 normal subjects (NLs), and 10 atrial fibrillation patients. Stress technetium-99m sestamibi G-SPECT was performed. Left ventricular (LV) contraction was evaluated in the beating slices. LVEF was calculated with G-SPECT using QGS (Cedars-Sinai, Los Angels) and p-FAST (Sapporo Medical University, Japan), and compared with that obtained by echocardiography (ECHO). LV volume curves were created by QGS and p-FAST. The heart rates (HRs) were calculated from the acquired images, and compared with their resting HRs. The mean count density of the myocardium was measured and time-activity curves were created. RESULTS In patients with GEs, bi-phasic LV contraction was demonstrated with fading-out towards end-diastole. G-SPECT underestimated LVEF compared to ECHO by 10% or more. The volume curves appeared "W-shaped." The HRs from the images were slower than the resting HRs. The count density decrement from frame #1 to #8 was larger than that of NLs. The time-activity curves were different in shape from those of NLs. CONCLUSIONS G-SPECT underestimates LVEF in patients with GEs. These errors can be identified with a combination of visual inspection of beating slices, time-volume curves, and time-activity curves. Monitoring the HR is a clue for anticipating and avoiding these errors.

UI MeSH Term Description Entries
D003951 Diagnostic Errors Incorrect or incomplete diagnoses following clinical or technical diagnostic procedures. Diagnostic Blind Spots,Errors, Diagnostic,Misdiagnosis,Blind Spot, Diagnostic,Blind Spots, Diagnostic,Diagnostic Blind Spot,Diagnostic Error,Error, Diagnostic,Misdiagnoses
D004562 Electrocardiography Recording of the moment-to-moment electromotive forces of the HEART as projected onto various sites on the body's surface, delineated as a scalar function of time. The recording is monitored by a tracing on slow moving chart paper or by observing it on a cardioscope, which is a CATHODE RAY TUBE DISPLAY. 12-Lead ECG,12-Lead EKG,12-Lead Electrocardiography,Cardiography,ECG,EKG,Electrocardiogram,Electrocardiograph,12 Lead ECG,12 Lead EKG,12 Lead Electrocardiography,12-Lead ECGs,12-Lead EKGs,12-Lead Electrocardiographies,Cardiographies,ECG, 12-Lead,EKG, 12-Lead,Electrocardiograms,Electrocardiographies, 12-Lead,Electrocardiographs,Electrocardiography, 12-Lead
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D001281 Atrial Fibrillation Abnormal cardiac rhythm that is characterized by rapid, uncoordinated firing of electrical impulses in the upper chambers of the heart (HEART ATRIA). In such case, blood cannot be effectively pumped into the lower chambers of the heart (HEART VENTRICLES). It is caused by abnormal impulse generation. Auricular Fibrillation,Familial Atrial Fibrillation,Paroxysmal Atrial Fibrillation,Persistent Atrial Fibrillation,Atrial Fibrillation, Familial,Atrial Fibrillation, Paroxysmal,Atrial Fibrillation, Persistent,Atrial Fibrillations,Atrial Fibrillations, Familial,Atrial Fibrillations, Paroxysmal,Atrial Fibrillations, Persistent,Auricular Fibrillations,Familial Atrial Fibrillations,Fibrillation, Atrial,Fibrillation, Auricular,Fibrillation, Familial Atrial,Fibrillation, Paroxysmal Atrial,Fibrillation, Persistent Atrial,Fibrillations, Atrial,Fibrillations, Auricular,Fibrillations, Familial Atrial,Fibrillations, Paroxysmal Atrial,Fibrillations, Persistent Atrial,Paroxysmal Atrial Fibrillations,Persistent Atrial Fibrillations
D012680 Sensitivity and Specificity Binary classification measures to assess test results. Sensitivity or recall rate is the proportion of true positives. Specificity is the probability of correctly determining the absence of a condition. (From Last, Dictionary of Epidemiology, 2d ed) Specificity,Sensitivity,Specificity and Sensitivity
D015203 Reproducibility of Results The statistical reproducibility of measurements (often in a clinical context), including the testing of instrumentation or techniques to obtain reproducible results. The concept includes reproducibility of physiological measurements, which may be used to develop rules to assess probability or prognosis, or response to a stimulus; reproducibility of occurrence of a condition; and reproducibility of experimental results. Reliability and Validity,Reliability of Result,Reproducibility Of Result,Reproducibility of Finding,Validity of Result,Validity of Results,Face Validity,Reliability (Epidemiology),Reliability of Results,Reproducibility of Findings,Test-Retest Reliability,Validity (Epidemiology),Finding Reproducibilities,Finding Reproducibility,Of Result, Reproducibility,Of Results, Reproducibility,Reliabilities, Test-Retest,Reliability, Test-Retest,Result Reliabilities,Result Reliability,Result Validities,Result Validity,Result, Reproducibility Of,Results, Reproducibility Of,Test Retest Reliability,Validity and Reliability,Validity, Face
D015637 Gated Blood-Pool Imaging Radionuclide ventriculography where scintigraphic data is acquired during repeated cardiac cycles at specific times in the cycle, using an electrocardiographic synchronizer or gating device. Analysis of right ventricular function is difficult with this technique; that is best evaluated by first-pass ventriculography (VENTRICULOGRAPHY, FIRST-PASS). Angiography, Gated Radionuclide,Equilibrium Radionuclide Angiography,Equilibrium Radionuclide Ventriculography,Gated Blood-Pool Scintigraphy,Gated Equilibrium Blood-Pool Scintigraphy,Radionuclide Angiography, Gated,Radionuclide Ventriculography, Gated,Scintigraphy, Equilibrium,Ventriculography, Equilibrium Radionuclide,Ventriculography, Gated Radionuclide,Blood-Pool Scintigraphy,Equilibrium Radionuclide Angiocardiography,Gated Equilibrium Blood Pool Scintigraphy,Angiocardiographies, Equilibrium Radionuclide,Angiocardiography, Equilibrium Radionuclide,Angiographies, Equilibrium Radionuclide,Angiographies, Gated Radionuclide,Angiography, Equilibrium Radionuclide,Blood Pool Scintigraphy,Blood-Pool Imaging, Gated,Blood-Pool Imagings, Gated,Blood-Pool Scintigraphies,Blood-Pool Scintigraphies, Gated,Blood-Pool Scintigraphy, Gated,Equilibrium Radionuclide Angiocardiographies,Equilibrium Radionuclide Angiographies,Equilibrium Radionuclide Ventriculographies,Equilibrium Scintigraphies,Equilibrium Scintigraphy,Gated Blood Pool Imaging,Gated Blood Pool Scintigraphy,Gated Blood-Pool Imagings,Gated Blood-Pool Scintigraphies,Gated Radionuclide Angiographies,Gated Radionuclide Angiography,Gated Radionuclide Ventriculographies,Gated Radionuclide Ventriculography,Imaging, Gated Blood-Pool,Imagings, Gated Blood-Pool,Radionuclide Angiocardiographies, Equilibrium,Radionuclide Angiocardiography, Equilibrium,Radionuclide Angiographies, Equilibrium,Radionuclide Angiographies, Gated,Radionuclide Angiography, Equilibrium,Radionuclide Ventriculographies, Equilibrium,Radionuclide Ventriculographies, Gated,Radionuclide Ventriculography, Equilibrium,Scintigraphies, Blood-Pool,Scintigraphies, Equilibrium,Scintigraphies, Gated Blood-Pool,Scintigraphy, Blood-Pool,Scintigraphy, Gated Blood-Pool,Ventriculographies, Equilibrium Radionuclide,Ventriculographies, Gated Radionuclide
D015899 Tomography, Emission-Computed, Single-Photon A method of computed tomography that uses radionuclides which emit a single photon of a given energy. The camera is rotated 180 or 360 degrees around the patient to capture images at multiple positions along the arc. The computer is then used to reconstruct the transaxial, sagittal, and coronal images from the 3-dimensional distribution of radionuclides in the organ. The advantages of SPECT are that it can be used to observe biochemical and physiological processes as well as size and volume of the organ. The disadvantage is that, unlike positron-emission tomography where the positron-electron annihilation results in the emission of 2 photons at 180 degrees from each other, SPECT requires physical collimation to line up the photons, which results in the loss of many available photons and hence degrades the image. CAT Scan, Single-Photon Emission,CT Scan, Single-Photon Emission,Radionuclide Tomography, Single-Photon Emission-Computed,SPECT,Single-Photon Emission-Computed Tomography,Tomography, Single-Photon, Emission-Computed,Single-Photon Emission CT Scan,Single-Photon Emission Computer-Assisted Tomography,Single-Photon Emission Computerized Tomography,CAT Scan, Single Photon Emission,CT Scan, Single Photon Emission,Emission-Computed Tomography, Single-Photon,Radionuclide Tomography, Single Photon Emission Computed,Single Photon Emission CT Scan,Single Photon Emission Computed Tomography,Single Photon Emission Computer Assisted Tomography,Single Photon Emission Computerized Tomography,Tomography, Single-Photon Emission-Computed
D016477 Artifacts Any visible result of a procedure which is caused by the procedure itself and not by the entity being analyzed. Common examples include histological structures introduced by tissue processing, radiographic images of structures that are not naturally present in living tissue, and products of chemical reactions that occur during analysis. Artefacts,Artefact,Artifact
D018487 Ventricular Dysfunction, Left A condition in which the LEFT VENTRICLE of the heart was functionally impaired. This condition usually leads to HEART FAILURE; MYOCARDIAL INFARCTION; and other cardiovascular complications. Diagnosis is made by measuring the diminished ejection fraction and a depressed level of motility of the left ventricular wall. LV Diastolic Dysfunction,LV Dysfunction,LV Systolic Dysfunction,Left Ventricular Diastolic Dysfunction,Left Ventricular Dysfunction,Left Ventricular Systolic Dysfunction,Diastolic Dysfunction, LV,Dysfunction, LV,Dysfunction, LV Diastolic,Dysfunction, LV Systolic,Dysfunction, Left Ventricular,LV Diastolic Dysfunctions,LV Dysfunctions,LV Systolic Dysfunctions,Left Ventricular Dysfunctions,Systolic Dysfunction, LV

Related Publications

Tokuo Kasai, and E Gordon DePuey, and Irwin Sponder
October 2017, Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology,
Tokuo Kasai, and E Gordon DePuey, and Irwin Sponder
January 2007, Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology,
Tokuo Kasai, and E Gordon DePuey, and Irwin Sponder
April 1994, American journal of cardiac imaging,
Tokuo Kasai, and E Gordon DePuey, and Irwin Sponder
October 2005, The American journal of cardiology,
Tokuo Kasai, and E Gordon DePuey, and Irwin Sponder
November 2006, Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology,
Tokuo Kasai, and E Gordon DePuey, and Irwin Sponder
August 2018, Nuclear medicine communications,
Tokuo Kasai, and E Gordon DePuey, and Irwin Sponder
August 2017, Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology,
Tokuo Kasai, and E Gordon DePuey, and Irwin Sponder
August 2023, Journal of cardiology,
Tokuo Kasai, and E Gordon DePuey, and Irwin Sponder
January 2005, Seminars in nuclear medicine,
Copied contents to your clipboard!