Detection of human red blood cell-bound nitric oxide. 2005

Stephen C Rogers, and Afshin Khalatbari, and Peter W Gapper, and Michael P Frenneaux, and Philip E James
Department of Cardiology, Wales Heart Research Institute, School of Medicine Cardiff University, Cardiff CF14 4XN.

Major disparities in reported levels of basal human nitric oxide metabolites have resulted in a recent literature focusing almost exclusively on methods. We chose to analyze triiodide chemiluminescence, drawn by the prospect of identifying why the most commonly employed assay in nitric oxide biology typically yielded lower metabolite values, compared with several other techniques. We found that the sensitivity of triiodide was greatly affected by the auto-capture of nitric oxide by deoxygenated cell-free heme in the reaction chamber. Potential contaminants and signal losses were also associated with standard sample purification procedures and the chemistry involved in nitrite removal. To inhibit heme nitric oxide auto-capture, we added potassium ferricyanide to the triiodide reagent, reasoning this would provide a more complete detection of any liberated nitric oxide. From human venous blood samples, we established nitric oxide levels ranging from 0.000178 to 0.00024 mol nitric oxide/mol hemoglobin. We went on to find significantly elevated nitric oxide levels in venous blood taken from diabetic patients in comparison to healthy controls (p < 0.0001). We concluded that the lack of signals reported of late by several groups using triiodide chemiluminescence for the detection of hemoglobin-bound nitric oxide may not represent levels on the border of assay sensitivity but rather underestimated values because of methodological limitations. We therefore stress the need for assay systems to be developed that differentiate between individual nitric oxide metabolite species and overcome the limitations we outline, allowing accurate conclusions to be drawn regarding physiological nitric oxide metabolite levels.

UI MeSH Term Description Entries
D007202 Indicators and Reagents Substances used for the detection, identification, analysis, etc. of chemical, biological, or pathologic processes or conditions. Indicators are substances that change in physical appearance, e.g., color, at or approaching the endpoint of a chemical titration, e.g., on the passage between acidity and alkalinity. Reagents are substances used for the detection or determination of another substance by chemical or microscopical means, especially analysis. Types of reagents are precipitants, solvents, oxidizers, reducers, fluxes, and colorimetric reagents. (From Grant & Hackh's Chemical Dictionary, 5th ed, p301, p499) Indicator,Reagent,Reagents,Indicators,Reagents and Indicators
D007454 Iodides Inorganic binary compounds of iodine or the I- ion. Iodide
D008163 Luminescent Measurements Techniques used for determining the values of photometric parameters of light resulting from LUMINESCENCE. Bioluminescence Measurements,Bioluminescent Assays,Bioluminescent Measurements,Chemiluminescence Measurements,Chemiluminescent Assays,Chemiluminescent Measurements,Chemoluminescence Measurements,Luminescence Measurements,Luminescent Assays,Luminescent Techniques,Phosphorescence Measurements,Phosphorescent Assays,Phosphorescent Measurements,Assay, Bioluminescent,Assay, Chemiluminescent,Assay, Luminescent,Assay, Phosphorescent,Assays, Bioluminescent,Assays, Chemiluminescent,Assays, Luminescent,Assays, Phosphorescent,Bioluminescence Measurement,Bioluminescent Assay,Bioluminescent Measurement,Chemiluminescence Measurement,Chemiluminescent Assay,Chemiluminescent Measurement,Chemoluminescence Measurement,Luminescence Measurement,Luminescent Assay,Luminescent Measurement,Luminescent Technique,Measurement, Bioluminescence,Measurement, Bioluminescent,Measurement, Chemiluminescence,Measurement, Chemiluminescent,Measurement, Chemoluminescence,Measurement, Luminescence,Measurement, Luminescent,Measurement, Phosphorescence,Measurement, Phosphorescent,Measurements, Bioluminescence,Measurements, Bioluminescent,Measurements, Chemiluminescence,Measurements, Chemiluminescent,Measurements, Chemoluminescence,Measurements, Luminescence,Measurements, Luminescent,Measurements, Phosphorescence,Measurements, Phosphorescent,Phosphorescence Measurement,Phosphorescent Assay,Phosphorescent Measurement,Technique, Luminescent,Techniques, Luminescent
D009569 Nitric Oxide A free radical gas produced endogenously by a variety of mammalian cells, synthesized from ARGININE by NITRIC OXIDE SYNTHASE. Nitric oxide is one of the ENDOTHELIUM-DEPENDENT RELAXING FACTORS released by the vascular endothelium and mediates VASODILATION. It also inhibits platelet aggregation, induces disaggregation of aggregated platelets, and inhibits platelet adhesion to the vascular endothelium. Nitric oxide activates cytosolic GUANYLATE CYCLASE and thus elevates intracellular levels of CYCLIC GMP. Endogenous Nitrate Vasodilator,Mononitrogen Monoxide,Nitric Oxide, Endothelium-Derived,Nitrogen Monoxide,Endothelium-Derived Nitric Oxide,Monoxide, Mononitrogen,Monoxide, Nitrogen,Nitrate Vasodilator, Endogenous,Nitric Oxide, Endothelium Derived,Oxide, Nitric,Vasodilator, Endogenous Nitrate
D003920 Diabetes Mellitus A heterogeneous group of disorders characterized by HYPERGLYCEMIA and GLUCOSE INTOLERANCE.
D004912 Erythrocytes Red blood cells. Mature erythrocytes are non-nucleated, biconcave disks containing HEMOGLOBIN whose function is to transport OXYGEN. Blood Cells, Red,Blood Corpuscles, Red,Red Blood Cells,Red Blood Corpuscles,Blood Cell, Red,Blood Corpuscle, Red,Erythrocyte,Red Blood Cell,Red Blood Corpuscle
D006454 Hemoglobins The oxygen-carrying proteins of ERYTHROCYTES. They are found in all vertebrates and some invertebrates. The number of globin subunits in the hemoglobin quaternary structure differs between species. Structures range from monomeric to a variety of multimeric arrangements. Eryhem,Ferrous Hemoglobin,Hemoglobin,Hemoglobin, Ferrous
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man

Related Publications

Stephen C Rogers, and Afshin Khalatbari, and Peter W Gapper, and Michael P Frenneaux, and Philip E James
January 2014, Biorheology,
Stephen C Rogers, and Afshin Khalatbari, and Peter W Gapper, and Michael P Frenneaux, and Philip E James
November 2016, Clinical hemorheology and microcirculation,
Stephen C Rogers, and Afshin Khalatbari, and Peter W Gapper, and Michael P Frenneaux, and Philip E James
May 2003, American journal of physiology. Heart and circulatory physiology,
Stephen C Rogers, and Afshin Khalatbari, and Peter W Gapper, and Michael P Frenneaux, and Philip E James
August 2000, British journal of haematology,
Stephen C Rogers, and Afshin Khalatbari, and Peter W Gapper, and Michael P Frenneaux, and Philip E James
April 2009, Trends in cardiovascular medicine,
Stephen C Rogers, and Afshin Khalatbari, and Peter W Gapper, and Michael P Frenneaux, and Philip E James
July 2018, Acta biochimica et biophysica Sinica,
Stephen C Rogers, and Afshin Khalatbari, and Peter W Gapper, and Michael P Frenneaux, and Philip E James
May 2013, Transfusion,
Stephen C Rogers, and Afshin Khalatbari, and Peter W Gapper, and Michael P Frenneaux, and Philip E James
September 2013, Proceedings of the National Academy of Sciences of the United States of America,
Stephen C Rogers, and Afshin Khalatbari, and Peter W Gapper, and Michael P Frenneaux, and Philip E James
September 2016, Clinical hemorheology and microcirculation,
Stephen C Rogers, and Afshin Khalatbari, and Peter W Gapper, and Michael P Frenneaux, and Philip E James
September 2016, Clinical hemorheology and microcirculation,
Copied contents to your clipboard!