Rapid quantification of nebivolol in human plasma by liquid chromatography coupled with electrospray ionization tandem mass spectrometry. 2005

N V S Ramakrishna, and K N Vishwottam, and M Koteshwara, and S Manoj, and M Santosh, and D P Varma
Biopharmaceutical Research, Suven Life Sciences Ltd., Serene Chambers, Road #7, Banjara Hills, Hyderabad 500034, India. nvsrk@suven.com

A simple, sensitive and rapid liquid chromatographic/electrospray ionization tandem mass spectrometric method was developed and validated for the quantitation of nebivolol in human plasma. The method involved a simple single-step liquid-liquid extraction with diethyl ether/dichloromethane (70/30). The analyte was chromatographed on Waters symmetry C18 reversed-phase chromatographic column by isocratic elution with water:acetonitrile:formic acid (30:70:0.03, v/v) and analyzed by mass spectrometry in the multiple reaction monitoring mode. The precursor to product ion transitions of m/z 406.4-151.5 and m/z 409.1-228.1 were used to measure the analyte and the internal standard (I.S.), respectively. The chromatographic runtime was 2 min and the weighted (1/x2) calibration curves were linear over the range 50-10,000 pg/mL. The method was validated in terms of accuracy, precision, absolute recovery, freeze-thaw stability, bench-top stability and re-injection reproducibility. The limit of detection and lower limit of quantification in human plasma were 10 and 50 pg/mL, respectively. The within- and between-batch accuracy and precision were found to be well within acceptable limits (<10%). The analyte was stable after three freeze-thaw cycles (deviation <10%). The average absolute recoveries of nebivolol and tamsulosin, used as an internal standard, from spiked plasma samples were 73.4+/-3.7 and 72.1+/-2.0%, respectively. The assay method described here was applied to study the pharmacokinetics of nebivolol.

UI MeSH Term Description Entries
D011786 Quality Control A system for verifying and maintaining a desired level of quality in a product or process by careful planning, use of proper equipment, continued inspection, and corrective action as required. (Random House Unabridged Dictionary, 2d ed) Control, Quality,Controls, Quality,Quality Controls
D002138 Calibration Determination, by measurement or comparison with a standard, of the correct value of each scale reading on a meter or other measuring instrument; or determination of the settings of a control device that correspond to particular values of voltage, current, frequency or other output. Calibrations
D002851 Chromatography, High Pressure Liquid Liquid chromatographic techniques which feature high inlet pressures, high sensitivity, and high speed. Chromatography, High Performance Liquid,Chromatography, High Speed Liquid,Chromatography, Liquid, High Pressure,HPLC,High Performance Liquid Chromatography,High-Performance Liquid Chromatography,UPLC,Ultra Performance Liquid Chromatography,Chromatography, High-Performance Liquid,High-Performance Liquid Chromatographies,Liquid Chromatography, High-Performance
D004983 Ethanolamines AMINO ALCOHOLS containing the ETHANOLAMINE; (-NH2CH2CHOH) group and its derivatives. Aminoethanols
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D000068577 Nebivolol A cardioselective ADRENERGIC BETA-1 RECEPTOR ANTAGONIST (beta-blocker) that functions as a VASODILATOR through the endothelial L-arginine/ NITRIC OXIDE system. It is used to manage HYPERTENSION and chronic HEART FAILURE in elderly patients. Alpha,Alpha'-(Iminobis(Methylene))bis(6-Fluoro-3,4-dihydro)-2H-1-benzopyran-2-methanol,Bystolic,Lobivon,Nebilet,Nebivolol Hydrochloride,R 67555,R-67555,Silostar,67555, R,Hydrochloride, Nebivolol,R67555
D000319 Adrenergic beta-Antagonists Drugs that bind to but do not activate beta-adrenergic receptors thereby blocking the actions of beta-adrenergic agonists. Adrenergic beta-antagonists are used for treatment of hypertension, cardiac arrhythmias, angina pectoris, glaucoma, migraine headaches, and anxiety. Adrenergic beta-Antagonist,Adrenergic beta-Receptor Blockader,Adrenergic beta-Receptor Blockaders,beta-Adrenergic Antagonist,beta-Adrenergic Blocker,beta-Adrenergic Blocking Agent,beta-Adrenergic Blocking Agents,beta-Adrenergic Receptor Blockader,beta-Adrenergic Receptor Blockaders,beta-Adrenoceptor Antagonist,beta-Blockers, Adrenergic,beta-Adrenergic Antagonists,beta-Adrenergic Blockers,beta-Adrenoceptor Antagonists,Adrenergic beta Antagonist,Adrenergic beta Antagonists,Adrenergic beta Receptor Blockader,Adrenergic beta Receptor Blockaders,Adrenergic beta-Blockers,Agent, beta-Adrenergic Blocking,Agents, beta-Adrenergic Blocking,Antagonist, beta-Adrenergic,Antagonist, beta-Adrenoceptor,Antagonists, beta-Adrenergic,Antagonists, beta-Adrenoceptor,Blockader, Adrenergic beta-Receptor,Blockader, beta-Adrenergic Receptor,Blockaders, Adrenergic beta-Receptor,Blockaders, beta-Adrenergic Receptor,Blocker, beta-Adrenergic,Blockers, beta-Adrenergic,Blocking Agent, beta-Adrenergic,Blocking Agents, beta-Adrenergic,Receptor Blockader, beta-Adrenergic,Receptor Blockaders, beta-Adrenergic,beta Adrenergic Antagonist,beta Adrenergic Antagonists,beta Adrenergic Blocker,beta Adrenergic Blockers,beta Adrenergic Blocking Agent,beta Adrenergic Blocking Agents,beta Adrenergic Receptor Blockader,beta Adrenergic Receptor Blockaders,beta Adrenoceptor Antagonist,beta Adrenoceptor Antagonists,beta Blockers, Adrenergic,beta-Antagonist, Adrenergic,beta-Antagonists, Adrenergic,beta-Receptor Blockader, Adrenergic,beta-Receptor Blockaders, Adrenergic
D001578 Benzopyrans Compounds with a core of fused benzo-pyran rings. Benzopyran,Chromene,Chromenes
D015203 Reproducibility of Results The statistical reproducibility of measurements (often in a clinical context), including the testing of instrumentation or techniques to obtain reproducible results. The concept includes reproducibility of physiological measurements, which may be used to develop rules to assess probability or prognosis, or response to a stimulus; reproducibility of occurrence of a condition; and reproducibility of experimental results. Reliability and Validity,Reliability of Result,Reproducibility Of Result,Reproducibility of Finding,Validity of Result,Validity of Results,Face Validity,Reliability (Epidemiology),Reliability of Results,Reproducibility of Findings,Test-Retest Reliability,Validity (Epidemiology),Finding Reproducibilities,Finding Reproducibility,Of Result, Reproducibility,Of Results, Reproducibility,Reliabilities, Test-Retest,Reliability, Test-Retest,Result Reliabilities,Result Reliability,Result Validities,Result Validity,Result, Reproducibility Of,Results, Reproducibility Of,Test Retest Reliability,Validity and Reliability,Validity, Face
D021241 Spectrometry, Mass, Electrospray Ionization A mass spectrometry technique used for analysis of nonvolatile compounds such as proteins and macromolecules. The technique involves preparing electrically charged droplets from analyte molecules dissolved in solvent. The electrically charged droplets enter a vacuum chamber where the solvent is evaporated. Evaporation of solvent reduces the droplet size, thereby increasing the coulombic repulsion within the droplet. As the charged droplets get smaller, the excess charge within them causes them to disintegrate and release analyte molecules. The volatilized analyte molecules are then analyzed by mass spectrometry. ESI Mass Spectrometry,Electrospray Ionization Mass Spectrometry,Mass Spectrometry, ESI,Spectrometry, ESI Mass

Related Publications

N V S Ramakrishna, and K N Vishwottam, and M Koteshwara, and S Manoj, and M Santosh, and D P Varma
January 2010, Journal of AOAC International,
N V S Ramakrishna, and K N Vishwottam, and M Koteshwara, and S Manoj, and M Santosh, and D P Varma
February 2003, Journal of mass spectrometry : JMS,
N V S Ramakrishna, and K N Vishwottam, and M Koteshwara, and S Manoj, and M Santosh, and D P Varma
August 2006, Biomedical chromatography : BMC,
N V S Ramakrishna, and K N Vishwottam, and M Koteshwara, and S Manoj, and M Santosh, and D P Varma
July 2011, Analytical and bioanalytical chemistry,
N V S Ramakrishna, and K N Vishwottam, and M Koteshwara, and S Manoj, and M Santosh, and D P Varma
September 2006, Biomedical chromatography : BMC,
N V S Ramakrishna, and K N Vishwottam, and M Koteshwara, and S Manoj, and M Santosh, and D P Varma
February 2007, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences,
N V S Ramakrishna, and K N Vishwottam, and M Koteshwara, and S Manoj, and M Santosh, and D P Varma
January 2003, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences,
N V S Ramakrishna, and K N Vishwottam, and M Koteshwara, and S Manoj, and M Santosh, and D P Varma
October 2004, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences,
N V S Ramakrishna, and K N Vishwottam, and M Koteshwara, and S Manoj, and M Santosh, and D P Varma
January 2005, Rapid communications in mass spectrometry : RCM,
N V S Ramakrishna, and K N Vishwottam, and M Koteshwara, and S Manoj, and M Santosh, and D P Varma
June 2015, Journal of separation science,
Copied contents to your clipboard!