Postoperative assessment of extracranial-intracranial bypass by time-resolved 3D contrast-enhanced MR angiography using parallel imaging. 2005

Kazuhiro Tsuchiya, and Keita Honya, and Akira Fujikawa, and Hidekatsu Tateishi, and Yoshiaki Shiokawa
Department of Radiology, Kyorin University School of Medicine, Tokyo, Japan.

OBJECTIVE Our goals were to assess image quality of time-resolved contrast-enhanced MR angiography (CE MRA), by using 3D data acquisition along with a parallel imaging technique that can improve temporal resolution and to compare this technique with 3D-time-of-flight (TOF) MRA in the postoperative assessment of extracranial (EC)-intracranial (IC) bypass surgery. METHODS On a 1.5T imaging system, we performed CE MRA by using a 3D fast field-echo sequence in combination with a parallel imaging technique, to obtain images in the coronal plane centered at the postoperative site. Our patient group comprised 17 patients, including 13 after superficial temporal artery-middle cerebral artery (MCA) anastomosis, 3 after external carotid artery-MCA anastomosis, and one after extracranial vertebral artery-posterior cerebral artery anastomosis. Visualization of the anastomosis and the distal flow on the CE-MRA images was assessed comparatively with that on 3D-TOF MR angiograms obtained at the same time. In 6 patients, we also compared the efficiency of visualization on CE-MRA images with that on conventional angiograms. RESULTS A temporal resolution of 0.8 s/frame could be achieved with the technique employed. The bypass was better demonstrated postoperatively on CE-MRA images than on 3D-TOF MR angiograms in 13 patients (76%), whereas the 2 methods were equivalent in 4 patients (24%). Good correspondence of results was observed in the 6 patients for whom CE MRA and conventional digital subtraction angiography (DSA) images were compared. CONCLUSIONS CE MRA by using the parallel imaging technique can increase image acquisition speed with sufficient image quality. This technique is at least equivalent to 3D-TOF MRA to evaluate the postoperative status of EC-IC bypass.

UI MeSH Term Description Entries
D007091 Image Processing, Computer-Assisted A technique of inputting two-dimensional or three-dimensional images into a computer and then enhancing or analyzing the imagery into a form that is more useful to the human observer. Biomedical Image Processing,Computer-Assisted Image Processing,Digital Image Processing,Image Analysis, Computer-Assisted,Image Reconstruction,Medical Image Processing,Analysis, Computer-Assisted Image,Computer-Assisted Image Analysis,Computer Assisted Image Analysis,Computer Assisted Image Processing,Computer-Assisted Image Analyses,Image Analyses, Computer-Assisted,Image Analysis, Computer Assisted,Image Processing, Biomedical,Image Processing, Computer Assisted,Image Processing, Digital,Image Processing, Medical,Image Processings, Medical,Image Reconstructions,Medical Image Processings,Processing, Biomedical Image,Processing, Digital Image,Processing, Medical Image,Processings, Digital Image,Processings, Medical Image,Reconstruction, Image,Reconstructions, Image
D008297 Male Males
D008875 Middle Aged An adult aged 45 - 64 years. Middle Age
D002548 Cerebral Revascularization Microsurgical revascularization to improve intracranial circulation. It usually involves joining the extracranial circulation to the intracranial circulation but may include extracranial revascularization (e.g., subclavian-vertebral artery bypass, subclavian-external carotid artery bypass). It is performed by joining two arteries (direct anastomosis or use of graft) or by free autologous transplantation of highly vascularized tissue to the surface of the brain. Brain Revascularization,EC-IC Arterial Bypass,Extracranial-Intracranial Arterial Bypass,Microsurgical Revascularization, Cerebral,STA-MCA Bypass,Cerebral Microsurgical Revascularization,Arterial Bypass, EC-IC,Arterial Bypass, Extracranial-Intracranial,Arterial Bypasses, EC-IC,Arterial Bypasses, Extracranial-Intracranial,Bypass, EC-IC Arterial,Bypass, Extracranial-Intracranial Arterial,Bypass, STA-MCA,Bypasses, EC-IC Arterial,Bypasses, Extracranial-Intracranial Arterial,Bypasses, STA-MCA,Cerebral Microsurgical Revascularizations,EC IC Arterial Bypass,EC-IC Arterial Bypasses,Extracranial Intracranial Arterial Bypass,Extracranial-Intracranial Arterial Bypasses,Revascularization, Brain,Revascularization, Cerebral,Revascularization, Cerebral Microsurgical,STA MCA Bypass,STA-MCA Bypasses
D003287 Contrast Media Substances used to allow enhanced visualization of tissues. Radiopaque Media,Contrast Agent,Contrast Agents,Contrast Material,Contrast Materials,Radiocontrast Agent,Radiocontrast Agents,Radiocontrast Media,Agent, Contrast,Agent, Radiocontrast,Agents, Contrast,Agents, Radiocontrast,Material, Contrast,Materials, Contrast,Media, Contrast,Media, Radiocontrast,Media, Radiopaque
D005260 Female Females
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D000328 Adult A person having attained full growth or maturity. Adults are of 19 through 44 years of age. For a person between 19 and 24 years of age, YOUNG ADULT is available. Adults
D000368 Aged A person 65 years of age or older. For a person older than 79 years, AGED, 80 AND OVER is available. Elderly
D015203 Reproducibility of Results The statistical reproducibility of measurements (often in a clinical context), including the testing of instrumentation or techniques to obtain reproducible results. The concept includes reproducibility of physiological measurements, which may be used to develop rules to assess probability or prognosis, or response to a stimulus; reproducibility of occurrence of a condition; and reproducibility of experimental results. Reliability and Validity,Reliability of Result,Reproducibility Of Result,Reproducibility of Finding,Validity of Result,Validity of Results,Face Validity,Reliability (Epidemiology),Reliability of Results,Reproducibility of Findings,Test-Retest Reliability,Validity (Epidemiology),Finding Reproducibilities,Finding Reproducibility,Of Result, Reproducibility,Of Results, Reproducibility,Reliabilities, Test-Retest,Reliability, Test-Retest,Result Reliabilities,Result Reliability,Result Validities,Result Validity,Result, Reproducibility Of,Results, Reproducibility Of,Test Retest Reliability,Validity and Reliability,Validity, Face

Related Publications

Kazuhiro Tsuchiya, and Keita Honya, and Akira Fujikawa, and Hidekatsu Tateishi, and Yoshiaki Shiokawa
September 1996, Magnetic resonance in medicine,
Kazuhiro Tsuchiya, and Keita Honya, and Akira Fujikawa, and Hidekatsu Tateishi, and Yoshiaki Shiokawa
April 2008, Journal of magnetic resonance imaging : JMRI,
Kazuhiro Tsuchiya, and Keita Honya, and Akira Fujikawa, and Hidekatsu Tateishi, and Yoshiaki Shiokawa
March 2002, AJNR. American journal of neuroradiology,
Kazuhiro Tsuchiya, and Keita Honya, and Akira Fujikawa, and Hidekatsu Tateishi, and Yoshiaki Shiokawa
April 2006, AJNR. American journal of neuroradiology,
Kazuhiro Tsuchiya, and Keita Honya, and Akira Fujikawa, and Hidekatsu Tateishi, and Yoshiaki Shiokawa
July 2015, Journal of magnetic resonance imaging : JMRI,
Kazuhiro Tsuchiya, and Keita Honya, and Akira Fujikawa, and Hidekatsu Tateishi, and Yoshiaki Shiokawa
September 2003, RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin,
Kazuhiro Tsuchiya, and Keita Honya, and Akira Fujikawa, and Hidekatsu Tateishi, and Yoshiaki Shiokawa
February 2010, VASA. Zeitschrift fur Gefasskrankheiten,
Kazuhiro Tsuchiya, and Keita Honya, and Akira Fujikawa, and Hidekatsu Tateishi, and Yoshiaki Shiokawa
April 2007, Journal of magnetic resonance imaging : JMRI,
Kazuhiro Tsuchiya, and Keita Honya, and Akira Fujikawa, and Hidekatsu Tateishi, and Yoshiaki Shiokawa
September 2006, Magnetic resonance in medicine,
Kazuhiro Tsuchiya, and Keita Honya, and Akira Fujikawa, and Hidekatsu Tateishi, and Yoshiaki Shiokawa
May 2007, AJNR. American journal of neuroradiology,
Copied contents to your clipboard!