Carpentier-Edwards PERIMOUNT Magna bioprosthesis: a stented valve with stentless performance? 2005

Pasquale Totaro, and Nello Degno, and Afzal Zaidi, and Aprim Youhana, and Vincenzo Argano
Cardiac Surgery Division, Regional Cardiac Centre, Morriston Hospital, Swansea, United Kingdom. ptotaro@yahoo.com

OBJECTIVE We designed this study to evaluate the early hemodynamic performance of the recently introduced Carpentier-Edwards PERIMOUNT Magna bioprosthesis (Edwards Lifesciences, Irvine, Calif) and compare it with those of the conventional Carpentier-Edwards PERIMOUNT stented bioprosthesis (Edwards Lifesciences) and Edwards Prima Plus porcine stentless bioprosthesis (Edwards Lifesciences). METHODS Sixty-three patients (>70 years old) were enrolled in this prospective, randomized study. At operation, once the annulus had been measured, the best size suitable was assessed for each of the three valves before random assignment. Transthoracic echocardiography was performed before discharge to evaluate early postoperative hemodynamic performances of the different valves implanted. RESULTS The best size suitable of Edwards Prima Plus (24.3 +/- 1.7 mm) was significantly superior to those of both the Carpentier-Edwards PERIMOUNT Magna (23.4 +/- 2.1 mm) and Carpentier-Edwards PERIMOUNT (22.4 +/- 1.8 mm). The best size suitable of the Carpentier-Edwards PERIMOUNT Magna, however, was significantly superior to that of the Carpentier-Edwards PERIMOUNT. Furthermore the best size suitable of the Carpentier-Edwards PERIMOUNT Magna was equal to the measured annulus in 55% of patients, as opposed to 25% for the Carpentier-Edwards PERIMOUNT (P < .001). Mean implanted labeled size of the Edwards Prima Plus was significantly higher than those of both the Carpentier-Edwards PERIMOUNT Magna and the Carpentier-Edwards PERIMOUNT (24.6 +/- 1.9 mm, 23.1 +/- 1.9 mm, and 22.5 +/- 1.8 mm, respectively). Early postoperative hemodynamic performance of the Carpentier-Edwards PERIMOUNT Magna, however, was superior to those of both the Edwards Prima Plus and the Carpentier-Edwards PERIMOUNT in both effective orifice area index (1.07 +/- 0.4 cm2/m2, 0.87 +/- 0.3 cm2/m2, and 0.80 +/- 0.2 cm2/m2, respectively) and mean peak gradient (20 +/- 6 mm Hg, 27 +/- 8 mm Hg, and 28 +/- 12 mm Hg, respectively). CONCLUSIONS The improved design of the recently introduced third-generation stented bioprosthesis Carpentier-Edwards PERIMOUNT Magna allows implantation of a significantly bigger valve than with the old generation. Furthermore, the improved hemodynamic performance of the Carpentier-Edwards PERIMOUNT Magna compares favorably with both the Carpentier-Edwards PERIMOUNT and the Edwards Prima Plus.

UI MeSH Term Description Entries
D008297 Male Males
D011446 Prospective Studies Observation of a population for a sufficient number of persons over a sufficient number of years to generate incidence or mortality rates subsequent to the selection of the study group. Prospective Study,Studies, Prospective,Study, Prospective
D011474 Prosthesis Design The plan and delineation of prostheses in general or a specific prosthesis. Design, Prosthesis,Designs, Prosthesis,Prosthesis Designs
D005260 Female Females
D006350 Heart Valve Prosthesis A device that substitutes for a heart valve. It may be composed of biological material (BIOPROSTHESIS) and/or synthetic material. Prosthesis, Heart Valve,Cardiac Valve Prosthesis,Cardiac Valve Prostheses,Heart Valve Prostheses,Prostheses, Cardiac Valve,Prostheses, Heart Valve,Prosthesis, Cardiac Valve,Valve Prostheses, Cardiac,Valve Prostheses, Heart,Valve Prosthesis, Cardiac,Valve Prosthesis, Heart
D006439 Hemodynamics The movement and the forces involved in the movement of the blood through the CARDIOVASCULAR SYSTEM. Hemodynamic
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D000368 Aged A person 65 years of age or older. For a person older than 79 years, AGED, 80 AND OVER is available. Elderly
D001021 Aortic Valve The valve between the left ventricle and the ascending aorta which prevents backflow into the left ventricle. Aortic Valves,Valve, Aortic,Valves, Aortic
D001705 Bioprosthesis Prosthesis, usually heart valve, composed of biological material and whose durability depends upon the stability of the material after pretreatment, rather than regeneration by host cell ingrowth. Durability is achieved 1, mechanically by the interposition of a cloth, usually polytetrafluoroethylene, between the host and the graft, and 2, chemically by stabilization of the tissue by intermolecular linking, usually with glutaraldehyde, after removal of antigenic components, or the use of reconstituted and restructured biopolymers. Glutaraldehyde-Stabilized Grafts,Heterograft Bioprosthesis,Porcine Xenograft Bioprosthesis,Xenograft Bioprosthesis,Bioprostheses,Bioprostheses, Heterograft,Bioprostheses, Porcine Xenograft,Bioprostheses, Xenograft,Bioprosthesis, Heterograft,Bioprosthesis, Porcine Xenograft,Bioprosthesis, Xenograft,Glutaraldehyde Stabilized Grafts,Glutaraldehyde-Stabilized Graft,Graft, Glutaraldehyde-Stabilized,Grafts, Glutaraldehyde-Stabilized,Heterograft Bioprostheses,Porcine Xenograft Bioprostheses,Xenograft Bioprostheses,Xenograft Bioprostheses, Porcine,Xenograft Bioprosthesis, Porcine

Related Publications

Pasquale Totaro, and Nello Degno, and Afzal Zaidi, and Aprim Youhana, and Vincenzo Argano
June 2018, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery,
Pasquale Totaro, and Nello Degno, and Afzal Zaidi, and Aprim Youhana, and Vincenzo Argano
January 2016, Journal of cardiothoracic surgery,
Pasquale Totaro, and Nello Degno, and Afzal Zaidi, and Aprim Youhana, and Vincenzo Argano
April 2016, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery,
Pasquale Totaro, and Nello Degno, and Afzal Zaidi, and Aprim Youhana, and Vincenzo Argano
May 2007, International journal of cardiology,
Pasquale Totaro, and Nello Degno, and Afzal Zaidi, and Aprim Youhana, and Vincenzo Argano
May 2009, The Journal of heart valve disease,
Pasquale Totaro, and Nello Degno, and Afzal Zaidi, and Aprim Youhana, and Vincenzo Argano
May 2001, The Annals of thoracic surgery,
Pasquale Totaro, and Nello Degno, and Afzal Zaidi, and Aprim Youhana, and Vincenzo Argano
March 2014, The Journal of heart valve disease,
Pasquale Totaro, and Nello Degno, and Afzal Zaidi, and Aprim Youhana, and Vincenzo Argano
January 2016, Revista portuguesa de cirurgia cardio-toracica e vascular : orgao oficial da Sociedade Portuguesa de Cirurgia Cardio-Toracica e Vascular,
Pasquale Totaro, and Nello Degno, and Afzal Zaidi, and Aprim Youhana, and Vincenzo Argano
December 2015, Interactive cardiovascular and thoracic surgery,
Pasquale Totaro, and Nello Degno, and Afzal Zaidi, and Aprim Youhana, and Vincenzo Argano
June 2007, The Annals of thoracic surgery,
Copied contents to your clipboard!