Accuracy of the new ICare rebound tonometer vs. other portable tonometers in healthy eyes. 2006

Carlos García-Resúa, and José M González-Meijome, and Jorge Gilino, and Eva Yebra-Pimentel
Department of Applied Physics (Optometry Group), University of Santiago de Compostela, Spain.

OBJECTIVE The ICare (Tiolat Oy, Helsinki, Finland) is a new portable tonometer that measures intraocular pressure (IOP) with a new rebound method, in which a very light probe is used to make momentary contact with the cornea in slow motion. The purpose of this study is to assess the accuracy of the ICare IOP measurements by comparing them against other portable tonometers: Perkins applanation tonometer and Tono-Pen XL digital tonometer (Medtronic Solan, Jacksonville, FL). METHODS Sixty-five young subjects were assessed with each of the tonometers. ICare tonometry was performed first, followed by Perkins applanation tonometry and Tono-Pen XL in a random order. Regression analysis was used to evaluate the relationship between the Perkins tonometer and the remaining tonometers used in this study. Tonometers were also compared by plotting the difference between the methods against the mean. The hypothesis of zero bias was examined by a paired t test and the 95% limits of agreement (LoA) were calculated. RESULTS ICare and Tono-Pen XL significantly overestimate IOP when compared with Perkins applanation tonometry. The mean of the difference between Perkins and ICare and Perkins and Tono-Pen XL was (mean +/- standard deviation) -3.35 +/- 2.28 mm Hg and -2.78 +/- 2.53 mm Hg, respectively. The 95% LoA between Perkins tonometry and ICare tonometry were between -7.81 and +1.12 and between Perkins tonometry and Tono-Pen XL tonometry between -7.74 and +2.18. CONCLUSIONS Compared with Perkins tonometry, the ICare tonometer allows clinicians to estimate IOP with a portable, rapid, and noninvasive method with similar reliability to that offered by Tono-Pen XL. Clinicians should be aware of the systematic overestimation of IOP with the ICare. Further research is needed to evaluate the performance of rebound tonometry in populations with higher IOP and assess the reliability of this technique in the early detection and follow up of glaucomatous patients.

UI MeSH Term Description Entries
D007429 Intraocular Pressure The pressure of the fluids in the eye. Ocular Tension,Intraocular Pressures,Ocular Tensions,Pressure, Intraocular,Pressures, Intraocular,Tension, Ocular,Tensions, Ocular
D008297 Male Males
D012016 Reference Values The range or frequency distribution of a measurement in a population (of organisms, organs or things) that has not been selected for the presence of disease or abnormality. Normal Range,Normal Values,Reference Ranges,Normal Ranges,Normal Value,Range, Normal,Range, Reference,Ranges, Normal,Ranges, Reference,Reference Range,Reference Value,Value, Normal,Value, Reference,Values, Normal,Values, Reference
D004867 Equipment Design Methods and patterns of fabricating machines and related hardware. Design, Equipment,Device Design,Medical Device Design,Design, Medical Device,Designs, Medical Device,Device Design, Medical,Device Designs, Medical,Medical Device Designs,Design, Device,Designs, Device,Designs, Equipment,Device Designs,Equipment Designs
D005260 Female Females
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D000328 Adult A person having attained full growth or maturity. Adults are of 19 through 44 years of age. For a person between 19 and 24 years of age, YOUNG ADULT is available. Adults
D014065 Tonometry, Ocular Measurement of ocular tension (INTRAOCULAR PRESSURE) with a tonometer. (Cline, et al., Dictionary of Visual Science, 4th ed) Ocular Tonometry
D015203 Reproducibility of Results The statistical reproducibility of measurements (often in a clinical context), including the testing of instrumentation or techniques to obtain reproducible results. The concept includes reproducibility of physiological measurements, which may be used to develop rules to assess probability or prognosis, or response to a stimulus; reproducibility of occurrence of a condition; and reproducibility of experimental results. Reliability and Validity,Reliability of Result,Reproducibility Of Result,Reproducibility of Finding,Validity of Result,Validity of Results,Face Validity,Reliability (Epidemiology),Reliability of Results,Reproducibility of Findings,Test-Retest Reliability,Validity (Epidemiology),Finding Reproducibilities,Finding Reproducibility,Of Result, Reproducibility,Of Results, Reproducibility,Reliabilities, Test-Retest,Reliability, Test-Retest,Result Reliabilities,Result Reliability,Result Validities,Result Validity,Result, Reproducibility Of,Results, Reproducibility Of,Test Retest Reliability,Validity and Reliability,Validity, Face

Related Publications

Carlos García-Resúa, and José M González-Meijome, and Jorge Gilino, and Eva Yebra-Pimentel
September 2015, Journal of glaucoma,
Carlos García-Resúa, and José M González-Meijome, and Jorge Gilino, and Eva Yebra-Pimentel
April 2018, International ophthalmology,
Carlos García-Resúa, and José M González-Meijome, and Jorge Gilino, and Eva Yebra-Pimentel
January 2008, Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists),
Carlos García-Resúa, and José M González-Meijome, and Jorge Gilino, and Eva Yebra-Pimentel
January 2011, Journal of glaucoma,
Carlos García-Resúa, and José M González-Meijome, and Jorge Gilino, and Eva Yebra-Pimentel
June 2016, Journal of glaucoma,
Carlos García-Resúa, and José M González-Meijome, and Jorge Gilino, and Eva Yebra-Pimentel
January 2011, Journal of glaucoma,
Carlos García-Resúa, and José M González-Meijome, and Jorge Gilino, and Eva Yebra-Pimentel
January 2021, Ophthalmic research,
Carlos García-Resúa, and José M González-Meijome, and Jorge Gilino, and Eva Yebra-Pimentel
January 2010, Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists),
Carlos García-Resúa, and José M González-Meijome, and Jorge Gilino, and Eva Yebra-Pimentel
August 2019, Experimental eye research,
Carlos García-Resúa, and José M González-Meijome, and Jorge Gilino, and Eva Yebra-Pimentel
May 2017, Experimental and therapeutic medicine,
Copied contents to your clipboard!