Determination of amiodarone and desethylamiodarone in horse plasma and urine by high-performance liquid chromatography combined with UV detection and electrospray ionization mass spectrometry. 2006

A Maes, and K Baert, and S Croubels, and D De Clercq, and G van Loon, and P Deprez, and P De Backer
Department of Pharmacology, Toxicology, Biochemistry and Organ Physiology, Ghent University, Salisburylaan 133, B-9820 Merelbeke, Belgium. an.maes@ugent.be

A rapid method for the quantification of amiodarone and desethylamiodarone in animal plasma using high-performance liquid chromatography combined with UV detection (HPLC-UV) is presented. The sample preparation includes a simple deproteinisation step with acetonitrile. In addition, a sensitive method for the quantification of amiodarone and desethylamiodarone in horse plasma and urine using high-performance liquid chromatography combined with electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) is described. The sample preparation includes a solid-phase extraction (SPE) with a SCX column. Tamoxifen is used as an internal standard for both chromatographic methods. Chromatographic separation is achieved on an ODS Hypersil column using isocratic elution with 0.01% diethylamine and acetonitrile as mobile phase for the HPLC-UV method and with 0.1% formic acid and acetonitrile as mobile phase for the LC-MS/MS method. For the HPLC-UV method, good linearity was observed in the range 0-5 microg ml(-1), and in the range 0-1 microg ml(-1) for the LC-MS/MS method. The limit of quantification (LOQ) was set at 50 and 5 ng ml(-1) for the HPLC-UV method and the LC-MS/MS method, respectively. For the UV method, the limit of detection (LOD) was 15 and 10 ng ml(-1) for amiodarone and desethylamiodarone, respectively. The LODs of the LC-MS/MS method in plasma were much lower, i.e. 0.10 and 0.04 ng ml(-1) for amiodarone and desethylamiodarone, respectively. The LODs obtained for the urine samples were 0.16 and 0.09 ng ml(-1) for amiodarone and desethylamiodarone, respectively. The methods were shown to be of use in horses. The rapid HPLC-UV method was used for therapeutic drug monitoring after amiodarone treatment, while the LC-MS/MS method showed its applicability for single dose pharmacokinetic studies.

UI MeSH Term Description Entries
D012015 Reference Standards A basis of value established for the measure of quantity, weight, extent or quality, e.g. weight standards, standard solutions, methods, techniques, and procedures used in diagnosis and therapy. Standard Preparations,Standards, Reference,Preparations, Standard,Standardization,Standards,Preparation, Standard,Reference Standard,Standard Preparation,Standard, Reference
D002851 Chromatography, High Pressure Liquid Liquid chromatographic techniques which feature high inlet pressures, high sensitivity, and high speed. Chromatography, High Performance Liquid,Chromatography, High Speed Liquid,Chromatography, Liquid, High Pressure,HPLC,High Performance Liquid Chromatography,High-Performance Liquid Chromatography,UPLC,Ultra Performance Liquid Chromatography,Chromatography, High-Performance Liquid,High-Performance Liquid Chromatographies,Liquid Chromatography, High-Performance
D006736 Horses Large, hoofed mammals of the family EQUIDAE. Horses are active day and night with most of the day spent seeking and consuming food. Feeding peaks occur in the early morning and late afternoon, and there are several daily periods of rest. Equus caballus,Equus przewalskii,Horse, Domestic,Domestic Horse,Domestic Horses,Horse,Horses, Domestic
D000638 Amiodarone An antianginal and class III antiarrhythmic drug. It increases the duration of ventricular and atrial muscle action by inhibiting POTASSIUM CHANNELS and VOLTAGE-GATED SODIUM CHANNELS. There is a resulting decrease in heart rate and in vascular resistance. Amiobeta,Amiodarex,Amiodarona,Amiodarone Hydrochloride,Amiohexal,Aratac,Braxan,Corbionax,Cordarex,Cordarone,Kordaron,L-3428,Ortacrone,Rytmarone,SKF 33134-A,Tachydaron,Trangorex,Hydrochloride, Amiodarone,L 3428,L3428,SKF 33134 A,SKF 33134A
D000818 Animals Unicellular or multicellular, heterotrophic organisms, that have sensation and the power of voluntary movement. Under the older five kingdom paradigm, Animalia was one of the kingdoms. Under the modern three domain model, Animalia represents one of the many groups in the domain EUKARYOTA. Animal,Metazoa,Animalia
D012680 Sensitivity and Specificity Binary classification measures to assess test results. Sensitivity or recall rate is the proportion of true positives. Specificity is the probability of correctly determining the absence of a condition. (From Last, Dictionary of Epidemiology, 2d ed) Specificity,Sensitivity,Specificity and Sensitivity
D013056 Spectrophotometry, Ultraviolet Determination of the spectra of ultraviolet absorption by specific molecules in gases or liquids, for example Cl2, SO2, NO2, CS2, ozone, mercury vapor, and various unsaturated compounds. (McGraw-Hill Dictionary of Scientific and Technical Terms, 4th ed) Ultraviolet Spectrophotometry
D021241 Spectrometry, Mass, Electrospray Ionization A mass spectrometry technique used for analysis of nonvolatile compounds such as proteins and macromolecules. The technique involves preparing electrically charged droplets from analyte molecules dissolved in solvent. The electrically charged droplets enter a vacuum chamber where the solvent is evaporated. Evaporation of solvent reduces the droplet size, thereby increasing the coulombic repulsion within the droplet. As the charged droplets get smaller, the excess charge within them causes them to disintegrate and release analyte molecules. The volatilized analyte molecules are then analyzed by mass spectrometry. ESI Mass Spectrometry,Electrospray Ionization Mass Spectrometry,Mass Spectrometry, ESI,Spectrometry, ESI Mass

Related Publications

A Maes, and K Baert, and S Croubels, and D De Clercq, and G van Loon, and P Deprez, and P De Backer
January 2002, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences,
A Maes, and K Baert, and S Croubels, and D De Clercq, and G van Loon, and P Deprez, and P De Backer
August 2002, Journal of mass spectrometry : JMS,
A Maes, and K Baert, and S Croubels, and D De Clercq, and G van Loon, and P Deprez, and P De Backer
February 2009, Biomedical chromatography : BMC,
A Maes, and K Baert, and S Croubels, and D De Clercq, and G van Loon, and P Deprez, and P De Backer
January 2004, Rapid communications in mass spectrometry : RCM,
A Maes, and K Baert, and S Croubels, and D De Clercq, and G van Loon, and P Deprez, and P De Backer
January 2003, Rapid communications in mass spectrometry : RCM,
A Maes, and K Baert, and S Croubels, and D De Clercq, and G van Loon, and P Deprez, and P De Backer
September 2011, Journal of pharmaceutical and biomedical analysis,
A Maes, and K Baert, and S Croubels, and D De Clercq, and G van Loon, and P Deprez, and P De Backer
July 2008, Biomedical chromatography : BMC,
A Maes, and K Baert, and S Croubels, and D De Clercq, and G van Loon, and P Deprez, and P De Backer
June 2007, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences,
A Maes, and K Baert, and S Croubels, and D De Clercq, and G van Loon, and P Deprez, and P De Backer
February 1997, Journal of chromatography. B, Biomedical sciences and applications,
Copied contents to your clipboard!