Monte Carlo dosimetric evaluation of high energy vs low energy photon beams in low density tissues. 2006

Miltiadis F Tsiakalos, and Sotirios Stathakis, and George A Plataniotis, and Constantin Kappas, and Kiki Theodorou
Medical Physics Department, Medical School, University of Thessalia, Larissa, Hellas, Greece. tsiakalos@med.uth.gr

OBJECTIVE Low megavoltage photon beams are often the treatment choice in radiotherapy when low density heterogeneities are involved, because higher energies show some undesirable dosimetric effects. This work is aimed at investigating the effects of different energy selection for low density tissues. METHODS BEAMnrc was used to simulate simple treatment set-ups in a simple and a CT reconstructed lung phantom and an air-channel phantom. The dose distribution of 6, 15 and 20 MV photon beams was studied using single, AP/PA and three-field arrangements. RESULTS Our results showed no significant changes in the penumbra width in lung when a pair of opposed fields were used. The underdosage at the anterior/posterior tumor edge caused by the dose build-up at the lung-tumor interface reached 7% for a 5 x 5 cm AP/PA set-up. Shrinkage of the 90% isodose volume was noticed for the same set-up, which could be rectified by adding a lateral field. For the CT reconstructed phantom, the AP/PA set-up offered better tumor coverage when lower energies were used but for the three field set-up, higher energies resulted to better sparing of the lung tissue. For the air-channel set-up, adding an opposed field reduced the penumbra width. Using higher energies resulted in a 7% cold spot around the air-tissue interface for a 5 x 5 cm field. CONCLUSIONS The choice of energy for treatment in the low density areas is not a straightforward decision but depends on a number of parameters such as the beam set-up and the dosimetric criteria. Updated calculation algorithms should be used in order to be confident for the choice of energy of treatment.

UI MeSH Term Description Entries
D008175 Lung Neoplasms Tumors or cancer of the LUNG. Cancer of Lung,Lung Cancer,Pulmonary Cancer,Pulmonary Neoplasms,Cancer of the Lung,Neoplasms, Lung,Neoplasms, Pulmonary,Cancer, Lung,Cancer, Pulmonary,Cancers, Lung,Cancers, Pulmonary,Lung Cancers,Lung Neoplasm,Neoplasm, Lung,Neoplasm, Pulmonary,Pulmonary Cancers,Pulmonary Neoplasm
D009010 Monte Carlo Method In statistics, a technique for numerically approximating the solution of a mathematical problem by studying the distribution of some random variable, often generated by a computer. The name alludes to the randomness characteristic of the games of chance played at the gambling casinos in Monte Carlo. (From Random House Unabridged Dictionary, 2d ed, 1993) Method, Monte Carlo
D011829 Radiation Dosage The amount of radiation energy that is deposited in a unit mass of material, such as tissues of plants or animal. In RADIOTHERAPY, radiation dosage is expressed in gray units (Gy). In RADIOLOGIC HEALTH, the dosage is expressed by the product of absorbed dose (Gy) and quality factor (a function of linear energy transfer), and is called radiation dose equivalent in sievert units (Sv). Sievert Units,Dosage, Radiation,Gray Units,Gy Radiation,Sv Radiation Dose Equivalent,Dosages, Radiation,Radiation Dosages,Units, Gray,Units, Sievert
D011880 Radiotherapy Planning, Computer-Assisted Computer-assisted mathematical calculations of beam angles, intensities of radiation, and duration of irradiation in radiotherapy. Computer-Assisted Radiotherapy Planning,Dosimetry Calculations, Computer-Assisted,Planning, Computer-Assisted Radiotherapy,Calculation, Computer-Assisted Dosimetry,Calculations, Computer-Assisted Dosimetry,Computer Assisted Radiotherapy Planning,Computer-Assisted Dosimetry Calculation,Computer-Assisted Dosimetry Calculations,Dosimetry Calculation, Computer-Assisted,Dosimetry Calculations, Computer Assisted,Planning, Computer Assisted Radiotherapy,Radiotherapy Planning, Computer Assisted
D011882 Radiotherapy, High-Energy Radiotherapy using high-energy (megavolt or higher) ionizing radiation. Types of radiation include gamma rays, produced by a radioisotope within a teletherapy unit; x-rays, electrons, protons, alpha particles (helium ions) and heavy charged ions, produced by particle acceleration; and neutrons and pi-mesons (pions), produced as secondary particles following bombardment of a target with a primary particle. Megavolt Radiotherapy,High-Energy Radiotherapy,Radiotherapy, Megavolt,High Energy Radiotherapy,Radiotherapy, High Energy
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D000465 Algorithms A procedure consisting of a sequence of algebraic formulas and/or logical steps to calculate or determine a given task. Algorithm
D017785 Photons Discrete concentrations of energy, apparently massless elementary particles, that move at the speed of light. They are the unit or quantum of electromagnetic radiation. Photons are emitted when electrons move from one energy state to another. (From Hawley's Condensed Chemical Dictionary, 11th ed)
D019047 Phantoms, Imaging Devices or objects in various imaging techniques used to visualize or enhance visualization by simulating conditions encountered in the procedure. Phantoms are used very often in procedures employing or measuring x-irradiation or radioactive material to evaluate performance. Phantoms often have properties similar to human tissue. Water demonstrates absorbing properties similar to normal tissue, hence water-filled phantoms are used to map radiation levels. Phantoms are used also as teaching aids to simulate real conditions with x-ray or ultrasonic machines. (From Iturralde, Dictionary and Handbook of Nuclear Medicine and Clinical Imaging, 1990) Phantoms, Radiographic,Phantoms, Radiologic,Radiographic Phantoms,Radiologic Phantoms,Phantom, Radiographic,Phantom, Radiologic,Radiographic Phantom,Radiologic Phantom,Imaging Phantom,Imaging Phantoms,Phantom, Imaging
D020266 Radiotherapy, Conformal A therapy using IONIZING RADIATION where there is improved dose homogeneity within the tumor and reduced dosage to uninvolved structures. The precise shaping of dose distribution is achieved via the use of computer-controlled multileaf collimators. Conformal Radiotherapy,3-D Conformal Radiotherapy,Three-Dimensional Conformal Radiotherapy,3-D Conformal Radiotherapies,Conformal Radiotherapies,Conformal Radiotherapies, 3-D,Conformal Radiotherapies, Three-Dimensional,Conformal Radiotherapy, 3-D,Conformal Radiotherapy, Three-Dimensional,Radiotherapies, 3-D Conformal,Radiotherapies, Conformal,Radiotherapies, Three-Dimensional Conformal,Radiotherapy, 3-D Conformal,Radiotherapy, Three-Dimensional Conformal,Three Dimensional Conformal Radiotherapy,Three-Dimensional Conformal Radiotherapies

Related Publications

Miltiadis F Tsiakalos, and Sotirios Stathakis, and George A Plataniotis, and Constantin Kappas, and Kiki Theodorou
December 2009, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology,
Miltiadis F Tsiakalos, and Sotirios Stathakis, and George A Plataniotis, and Constantin Kappas, and Kiki Theodorou
August 2006, Nihon Hoshasen Gijutsu Gakkai zasshi,
Miltiadis F Tsiakalos, and Sotirios Stathakis, and George A Plataniotis, and Constantin Kappas, and Kiki Theodorou
January 2007, Physics in medicine and biology,
Miltiadis F Tsiakalos, and Sotirios Stathakis, and George A Plataniotis, and Constantin Kappas, and Kiki Theodorou
October 2012, Medical physics,
Miltiadis F Tsiakalos, and Sotirios Stathakis, and George A Plataniotis, and Constantin Kappas, and Kiki Theodorou
January 2013, Radiological physics and technology,
Miltiadis F Tsiakalos, and Sotirios Stathakis, and George A Plataniotis, and Constantin Kappas, and Kiki Theodorou
December 2009, Physics in medicine and biology,
Miltiadis F Tsiakalos, and Sotirios Stathakis, and George A Plataniotis, and Constantin Kappas, and Kiki Theodorou
November 2003, Physics in medicine and biology,
Miltiadis F Tsiakalos, and Sotirios Stathakis, and George A Plataniotis, and Constantin Kappas, and Kiki Theodorou
September 2007, Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine,
Miltiadis F Tsiakalos, and Sotirios Stathakis, and George A Plataniotis, and Constantin Kappas, and Kiki Theodorou
June 2008, Physics in medicine and biology,
Miltiadis F Tsiakalos, and Sotirios Stathakis, and George A Plataniotis, and Constantin Kappas, and Kiki Theodorou
September 2011, Zeitschrift fur medizinische Physik,
Copied contents to your clipboard!