Accuracy of a computer-assisted navigation system for total knee replacement. 2006

R P Pitto, and A J Graydon, and L Bradley, and S F Malak, and C G Walker, and I A Anderson
University of Auckland, and Department of Orthopaedics, Middlemore Hospital, 93311 Otahuhu, Auckland, New Zealand. RPitto@middlemore.co.nz

The object of this study was to develop a method to assess the accuracy of an image-free total knee replacement navigation system in legs with normal or abnormal mechanical axes. A phantom leg was constructed with simulated hip and knee joints and provided a means to locate the centre of the ankle joint. Additional joints located at the midshaft of the tibia and femur allowed deformation in the flexion/extension, varus/valgus and rotational planes. Using a digital caliper unit to measure the coordinates precisely, a software program was developed to convert these local coordinates into a determination of actual leg alignment. At specific points in the procedure, information was compared between the digital caliper measurements and the image-free navigation system. Repeated serial measurements were undertaken. In the setting of normal alignment the mean error of the system was within 0.5 degrees . In the setting of abnormal plane alignment in both the femur and the tibia, the error was within 1 degrees . This is the first study designed to assess the accuracy of a clinically-validated navigation system. It demonstrates in vitro accuracy of the image-free navigation system in both normal and abnormal leg alignment settings.

UI MeSH Term Description Entries
D007719 Knee Joint A synovial hinge connection formed between the bones of the FEMUR; TIBIA; and PATELLA. Superior Tibiofibular Joint,Joint, Knee,Joint, Superior Tibiofibular,Knee Joints,Superior Tibiofibular Joints,Tibiofibular Joint, Superior
D007720 Knee Prosthesis Replacement for a knee joint. Knee Prostheses,Prostheses, Knee,Prosthesis, Knee
D007866 Leg The inferior part of the lower extremity between the KNEE and the ANKLE. Legs
D004867 Equipment Design Methods and patterns of fabricating machines and related hardware. Design, Equipment,Device Design,Medical Device Design,Design, Medical Device,Designs, Medical Device,Device Design, Medical,Device Designs, Medical,Medical Device Designs,Design, Device,Designs, Device,Designs, Equipment,Device Designs,Equipment Designs
D005269 Femur The longest and largest bone of the skeleton, it is situated between the hip and the knee. Trochanter,Greater Trochanter,Lesser Trochanter,Femurs,Greater Trochanters,Lesser Trochanters,Trochanter, Greater,Trochanter, Lesser,Trochanters,Trochanters, Greater,Trochanters, Lesser
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D001696 Biomechanical Phenomena The properties, processes, and behavior of biological systems under the action of mechanical forces. Biomechanics,Kinematics,Biomechanic Phenomena,Mechanobiological Phenomena,Biomechanic,Biomechanic Phenomenas,Phenomena, Biomechanic,Phenomena, Biomechanical,Phenomena, Mechanobiological,Phenomenas, Biomechanic
D012399 Rotation Motion of an object in which either one or more points on a line are fixed. It is also the motion of a particle about a fixed point. (From McGraw-Hill Dictionary of Scientific and Technical Terms, 4th ed) Clinorotation,Clinorotations,Rotations
D013977 Tibia The second longest bone of the skeleton. It is located on the medial side of the lower leg, articulating with the FIBULA laterally, the TALUS distally, and the FEMUR proximally. Tibias
D017760 Bone Malalignment Displacement of bones out of line in relation to joints. It may be congenital or traumatic in origin. Bone Malposition,Bone Misalignment,Bone Malalignments,Bone Malpositions,Bone Misalignments,Malalignment, Bone,Malposition, Bone,Misalignment, Bone

Related Publications

R P Pitto, and A J Graydon, and L Bradley, and S F Malak, and C G Walker, and I A Anderson
March 2010, Operative Orthopadie und Traumatologie,
R P Pitto, and A J Graydon, and L Bradley, and S F Malak, and C G Walker, and I A Anderson
January 2000, Studies in health technology and informatics,
R P Pitto, and A J Graydon, and L Bradley, and S F Malak, and C G Walker, and I A Anderson
February 2008, Technology Evaluation Center Assessment Program. Executive summary,
R P Pitto, and A J Graydon, and L Bradley, and S F Malak, and C G Walker, and I A Anderson
January 2013, ISRN orthopedics,
R P Pitto, and A J Graydon, and L Bradley, and S F Malak, and C G Walker, and I A Anderson
August 2005, The Journal of bone and joint surgery. British volume,
R P Pitto, and A J Graydon, and L Bradley, and S F Malak, and C G Walker, and I A Anderson
April 2011, The Journal of arthroplasty,
R P Pitto, and A J Graydon, and L Bradley, and S F Malak, and C G Walker, and I A Anderson
August 2007, The Journal of bone and joint surgery. British volume,
R P Pitto, and A J Graydon, and L Bradley, and S F Malak, and C G Walker, and I A Anderson
May 2020, Surgical technology international,
R P Pitto, and A J Graydon, and L Bradley, and S F Malak, and C G Walker, and I A Anderson
February 2006, Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi,
R P Pitto, and A J Graydon, and L Bradley, and S F Malak, and C G Walker, and I A Anderson
May 2008, Computer aided surgery : official journal of the International Society for Computer Aided Surgery,
Copied contents to your clipboard!