Bioimpedance cardiography measurements of cardiac output and other cardiovascular parameters. 2006

Nancy M Albert
Cleveland Clinic, 9500 Euclid Avenue, P-32, Cleveland, OH 44195, USA. albertn@ccf.org

This paper describes impedance technique and device types, discusses hemodynamic data parameters that are available, discusses the differences between impedance cardiography and data that are derived from invasive pulmonary artery catheters, and explains how nurses can apply bioimpedance cardiography in a variety of patient populations.

UI MeSH Term Description Entries
D006973 Hypertension Persistently high systemic arterial BLOOD PRESSURE. Based on multiple readings (BLOOD PRESSURE DETERMINATION), hypertension is currently defined as when SYSTOLIC PRESSURE is consistently greater than 140 mm Hg or when DIASTOLIC PRESSURE is consistently 90 mm Hg or more. Blood Pressure, High,Blood Pressures, High,High Blood Pressure,High Blood Pressures
D008991 Monitoring, Physiologic The continuous measurement of physiological processes, blood pressure, heart rate, renal output, reflexes, respiration, etc., in a patient or experimental animal; includes pharmacologic monitoring, the measurement of administered drugs or their metabolites in the blood, tissues, or urine. Patient Monitoring,Monitoring, Physiological,Physiologic Monitoring,Monitoring, Patient,Physiological Monitoring
D009730 Nursing Assessment Evaluation of the nature and extent of nursing problems presented by a patient for the purpose of patient care planning. Nursing Protocols,Assessment, Nursing,Protocols, Nursing,Assessments, Nursing,Nursing Assessments,Nursing Protocol,Protocol, Nursing
D010138 Pacemaker, Artificial A device designed to stimulate, by electric impulses, contraction of the heart muscles. It may be temporary (external) or permanent (internal or internal-external). Cardiac Pacemaker, Artificial,Artificial Cardiac Pacemaker,Artificial Cardiac Pacemakers,Artificial Pacemaker,Artificial Pacemakers,Cardiac Pacemakers, Artificial,Pacemaker, Artificial Cardiac,Pacemakers, Artificial,Pacemakers, Artificial Cardiac
D001783 Blood Flow Velocity A value equal to the total volume flow divided by the cross-sectional area of the vascular bed. Blood Flow Velocities,Flow Velocities, Blood,Flow Velocity, Blood,Velocities, Blood Flow,Velocity, Blood Flow
D002302 Cardiac Output The volume of BLOOD passing through the HEART per unit of time. It is usually expressed as liters (volume) per minute so as not to be confused with STROKE VOLUME (volume per beat). Cardiac Outputs,Output, Cardiac,Outputs, Cardiac
D002307 Cardiography, Impedance A type of impedance plethysmography in which bioelectrical impedance is measured between electrodes positioned around the neck and around the lower thorax. It is used principally to calculate stroke volume and cardiac volume, but it is also related to myocardial contractility, thoracic fluid content, and circulation to the extremities. Impedance, Transthoracic,Plethysmography, Impedance, Transthoracic,Impedance Cardiography,Impedance Plethysmography, Transthoracic,Plethysmography, Transthoracic Impedance,Transthoracic Impedance Plethysmography,Cardiographies, Impedance,Impedance Cardiographies,Impedance Plethysmographies, Transthoracic,Impedances, Transthoracic,Plethysmographies, Transthoracic Impedance,Transthoracic Impedance,Transthoracic Impedance Plethysmographies,Transthoracic Impedances
D002407 Catheterization, Swan-Ganz Placement of a balloon-tipped catheter into the pulmonary artery through the antecubital, subclavian, and sometimes the femoral vein. It is used to measure pulmonary artery pressure and pulmonary artery wedge pressure which reflects left atrial pressure and left ventricular end-diastolic pressure. The catheter is threaded into the right atrium, the balloon is inflated and the catheter follows the blood flow through the tricuspid valve into the right ventricle and out into the pulmonary artery. Catheterization, Pulmonary Artery,Swan-Ganz Catheterization,Pulmonary Artery Catheterization,Artery Catheterization, Pulmonary,Artery Catheterizations, Pulmonary,Catheterization, Swan Ganz,Catheterizations, Pulmonary Artery,Pulmonary Artery Catheterizations,Swan Ganz Catheterization
D003422 Critical Care Health care provided to a critically ill patient during a medical emergency or crisis. Intensive Care,Intensive Care, Surgical,Surgical Intensive Care,Care, Critical,Care, Intensive,Care, Surgical Intensive
D006333 Heart Failure A heterogeneous condition in which the heart is unable to pump out sufficient blood to meet the metabolic need of the body. Heart failure can be caused by structural defects, functional abnormalities (VENTRICULAR DYSFUNCTION), or a sudden overload beyond its capacity. Chronic heart failure is more common than acute heart failure which results from sudden insult to cardiac function, such as MYOCARDIAL INFARCTION. Cardiac Failure,Heart Decompensation,Congestive Heart Failure,Heart Failure, Congestive,Heart Failure, Left-Sided,Heart Failure, Right-Sided,Left-Sided Heart Failure,Myocardial Failure,Right-Sided Heart Failure,Decompensation, Heart,Heart Failure, Left Sided,Heart Failure, Right Sided,Left Sided Heart Failure,Right Sided Heart Failure

Related Publications

Nancy M Albert
June 1990, Journal of the Royal Army Medical Corps,
Nancy M Albert
October 1990, Journal of the Royal Army Medical Corps,
Nancy M Albert
October 1983, Rinsho byori. The Japanese journal of clinical pathology,
Nancy M Albert
November 1992, Pacing and clinical electrophysiology : PACE,
Nancy M Albert
May 1990, Canadian journal of anaesthesia = Journal canadien d'anesthesie,
Nancy M Albert
September 1994, Critical care medicine,
Nancy M Albert
June 1997, Academic emergency medicine : official journal of the Society for Academic Emergency Medicine,
Nancy M Albert
March 1994, The Annals of physiological anthropology = Seiri Jinruigaku Kenkyukai kaishi,
Copied contents to your clipboard!