Single-photon emission computed tomography/computed tomography: basic instrumentation and innovations. 2006

Michael K O'Connor, and Brad J Kemp
Department of Nuclear Medicine, Mayo Clinic, Rochester, MN 55905, USA. mkoconnor@mayo.edu

Correlation of the anatomical and functional information presented by single-photon emission computed tomography (SPECT) and computed tomography (CT) can aid in the decision-making process by enabling better localization and definition of organs and lesions and improving the precision of surgical biopsies. Technical developments over the past 20 years have led to the development of better software techniques for image fusion and, more recently, to the development of modern SPECT/CT systems. While image fusion techniques have been in clinical use for many years, the first commercial SPECT/CT system was only developed in 1999. Following the commercial success of PET/CT systems that employed multidetector CT (MDCT) scanners, there has been renewed interest in the development of comparable SPECT/CT systems. This has resulted in the development of a range of SPECT/CT devices varying from a simple CT add-on to a conventional SPECT system that can provide low-dose CT images to a full MDCT scanner integrated with a SPECT system. The advantages of combining SPECT with CT are numerous and are primarily due to the anatomic referencing and the attenuation correction capabilities of CT. Depending on system design, there are varying technical issues surrounding the different SPECT/CT devices, ranging from cost, radiation dose, planning, and siting requirements to system-specific issues such as table sag and CT artifacts due to patient motion. Motion artifacts should be less prevalent with the faster acquisition times of modern scanners, but are still problematic in the thorax and have not yet been fully resolved as they pertain to the use of CT data for cardiac attenuation correction. As this technology matures, we can expect to see a range of SPECT/CT devices available on the market that range from low-dose 1-4 slice inexpensive CT upgrades of conventional SPECT systems, to SPECT systems incorporating 64 or 128 slices CT scanners. The cost of the high-end CT scanners will exceed the cost of the SPECT scanner and hence the justification for such devices will be heavily dependent on clear demonstration of their value in clinical practice.

UI MeSH Term Description Entries
D007089 Image Enhancement Improvement of the quality of a picture by various techniques, including computer processing, digital filtering, echocardiographic techniques, light and ultrastructural MICROSCOPY, fluorescence spectrometry and microscopy, scintigraphy, and in vitro image processing at the molecular level. Image Quality Enhancement,Enhancement, Image,Enhancement, Image Quality,Enhancements, Image,Enhancements, Image Quality,Image Enhancements,Image Quality Enhancements,Quality Enhancement, Image,Quality Enhancements, Image
D007090 Image Interpretation, Computer-Assisted Methods developed to aid in the interpretation of ultrasound, radiographic images, etc., for diagnosis of disease. Image Interpretation, Computer Assisted,Computer-Assisted Image Interpretation,Computer-Assisted Image Interpretations,Image Interpretations, Computer-Assisted,Interpretation, Computer-Assisted Image,Interpretations, Computer-Assisted Image
D004867 Equipment Design Methods and patterns of fabricating machines and related hardware. Design, Equipment,Device Design,Medical Device Design,Design, Medical Device,Designs, Medical Device,Device Design, Medical,Device Designs, Medical,Medical Device Designs,Design, Device,Designs, Device,Designs, Equipment,Device Designs,Equipment Designs
D013382 Subtraction Technique Combination or superimposition of two images for demonstrating differences between them (e.g., radiograph with contrast vs. one without, radionuclide images using different radionuclides, radiograph vs. radionuclide image) and in the preparation of audiovisual materials (e.g., offsetting identical images, coloring of vessels in angiograms). Subtraction Technic,Subtraction Technics,Subtraction Techniques,Technic, Subtraction,Technics, Subtraction,Technique, Subtraction,Techniques, Subtraction
D013673 Technology Assessment, Biomedical Evaluation of biomedical technology in relation to cost, efficacy, utilization, etc., and its future impact on social, ethical, and legal systems. Assessment, Biomedical Technology,Assessment, Technology,Biomedical Technology Assessment,Technology Assessment,Technology Assessment, Health,Assessment, Health Technology,Assessments, Biomedical Technology,Assessments, Health Technology,Assessments, Technology,Biomedical Technology Assessments,Health Technology Assessment,Health Technology Assessments,Technology Assessments,Technology Assessments, Biomedical,Technology Assessments, Health
D014057 Tomography, X-Ray Computed Tomography using x-ray transmission and a computer algorithm to reconstruct the image. CAT Scan, X-Ray,CT Scan, X-Ray,Cine-CT,Computerized Tomography, X-Ray,Electron Beam Computed Tomography,Tomodensitometry,Tomography, Transmission Computed,X-Ray Tomography, Computed,CAT Scan, X Ray,CT X Ray,Computed Tomography, X-Ray,Computed X Ray Tomography,Computerized Tomography, X Ray,Electron Beam Tomography,Tomography, X Ray Computed,Tomography, X-Ray Computer Assisted,Tomography, X-Ray Computerized,Tomography, X-Ray Computerized Axial,Tomography, Xray Computed,X Ray Computerized Tomography,X Ray Tomography, Computed,X-Ray Computer Assisted Tomography,X-Ray Computerized Axial Tomography,Beam Tomography, Electron,CAT Scans, X-Ray,CT Scan, X Ray,CT Scans, X-Ray,CT X Rays,Cine CT,Computed Tomography, Transmission,Computed Tomography, X Ray,Computed Tomography, Xray,Computed X-Ray Tomography,Scan, X-Ray CAT,Scan, X-Ray CT,Scans, X-Ray CAT,Scans, X-Ray CT,Tomographies, Computed X-Ray,Tomography, Computed X-Ray,Tomography, Electron Beam,Tomography, X Ray Computer Assisted,Tomography, X Ray Computerized,Tomography, X Ray Computerized Axial,Transmission Computed Tomography,X Ray Computer Assisted Tomography,X Ray Computerized Axial Tomography,X Ray, CT,X Rays, CT,X-Ray CAT Scan,X-Ray CAT Scans,X-Ray CT Scan,X-Ray CT Scans,X-Ray Computed Tomography,X-Ray Computerized Tomography,Xray Computed Tomography
D015899 Tomography, Emission-Computed, Single-Photon A method of computed tomography that uses radionuclides which emit a single photon of a given energy. The camera is rotated 180 or 360 degrees around the patient to capture images at multiple positions along the arc. The computer is then used to reconstruct the transaxial, sagittal, and coronal images from the 3-dimensional distribution of radionuclides in the organ. The advantages of SPECT are that it can be used to observe biochemical and physiological processes as well as size and volume of the organ. The disadvantage is that, unlike positron-emission tomography where the positron-electron annihilation results in the emission of 2 photons at 180 degrees from each other, SPECT requires physical collimation to line up the photons, which results in the loss of many available photons and hence degrades the image. CAT Scan, Single-Photon Emission,CT Scan, Single-Photon Emission,Radionuclide Tomography, Single-Photon Emission-Computed,SPECT,Single-Photon Emission-Computed Tomography,Tomography, Single-Photon, Emission-Computed,Single-Photon Emission CT Scan,Single-Photon Emission Computer-Assisted Tomography,Single-Photon Emission Computerized Tomography,CAT Scan, Single Photon Emission,CT Scan, Single Photon Emission,Emission-Computed Tomography, Single-Photon,Radionuclide Tomography, Single Photon Emission Computed,Single Photon Emission CT Scan,Single Photon Emission Computed Tomography,Single Photon Emission Computer Assisted Tomography,Single Photon Emission Computerized Tomography,Tomography, Single-Photon Emission-Computed

Related Publications

Michael K O'Connor, and Brad J Kemp
December 1985, Investigative radiology,
Michael K O'Connor, and Brad J Kemp
October 1990, Seminars in nuclear medicine,
Michael K O'Connor, and Brad J Kemp
November 1995, Neuroimaging clinics of North America,
Michael K O'Connor, and Brad J Kemp
October 2010, Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology,
Michael K O'Connor, and Brad J Kemp
January 1985, Computerized radiology : official journal of the Computerized Tomography Society,
Michael K O'Connor, and Brad J Kemp
October 2010, Physics in medicine and biology,
Michael K O'Connor, and Brad J Kemp
April 1996, Current opinion in neurology,
Michael K O'Connor, and Brad J Kemp
March 2001, Journal of nuclear medicine technology,
Michael K O'Connor, and Brad J Kemp
September 1995, Academic radiology,
Michael K O'Connor, and Brad J Kemp
October 2006, Seminars in nuclear medicine,
Copied contents to your clipboard!