Rotator cuff tears: assessment with MR arthrography in 275 patients with arthroscopic correlation. 2007

S Waldt, and M Bruegel, and D Mueller, and K Holzapfel, and A B Imhoff, and E J Rummeny, and K Woertler
Department of Radiology, Technische Universität München, Klinikum rechts der Isar, Ismaninger Strasse 22, D-81675 Munich, Germany. waldt@roe.med.tum.de

We assessed the diagnostic performance of magnetic resonance (MR) arthrography in the diagnosis of articular-sided partial-thickness and full-thickness rotator cuff tears in a large symptomatic population. MR arthrograms obtained in 275 patients including a study group of 139 patients with rotator cuff tears proved by arthroscopy and a control group of 136 patients with arthroscopically intact rotator cuff tendons were reviewed in random order. MR imaging was performed on a 1.0 T system (Magnetom Expert, Siemens). MR arthrograms were analyzed by two radiologists in consensus for articular-sided partial-thickness and full-thickness tears of the supraspinatus, infraspinatus, and subscapularis tendons. At arthroscopy, 197 rotator cuff tears were diagnosed, including 105 partial-thickness (93 supraspinatus, nine infraspinatus, three subscapularis) and 92 full-thickness (43 supraspinatus, 20 infraspinatus, 29 subscapularis) tendon tears. For full-thickness tears, sensitivity, specificity, and accuracy were 96%, 99%, and 98%, respectively, and for partial tears 80%, 97%, and 95%, respectively. False negative and positive assessments in the diagnosis of articular-sided partial-thickness tears were predominantly [78% (35/45)] observed with small articular-sided (Ellman grade1) tendon tears. MR arthrography is highly accurate in the diagnosis of full-thickness rotator cuff tears and is accurate in the diagnosis of articular-sided partial-thickness tears. Limitations in the diagnosis of partial-thickness tears are mainly restricted to small articular-sided tears (Ellman grade 1) due to difficulties in differentiation between fiber tearing, tendinitis, synovitic changes, and superficial fraying at tendon margins.

UI MeSH Term Description Entries
D007090 Image Interpretation, Computer-Assisted Methods developed to aid in the interpretation of ultrasound, radiographic images, etc., for diagnosis of disease. Image Interpretation, Computer Assisted,Computer-Assisted Image Interpretation,Computer-Assisted Image Interpretations,Image Interpretations, Computer-Assisted,Interpretation, Computer-Assisted Image,Interpretations, Computer-Assisted Image
D007091 Image Processing, Computer-Assisted A technique of inputting two-dimensional or three-dimensional images into a computer and then enhancing or analyzing the imagery into a form that is more useful to the human observer. Biomedical Image Processing,Computer-Assisted Image Processing,Digital Image Processing,Image Analysis, Computer-Assisted,Image Reconstruction,Medical Image Processing,Analysis, Computer-Assisted Image,Computer-Assisted Image Analysis,Computer Assisted Image Analysis,Computer Assisted Image Processing,Computer-Assisted Image Analyses,Image Analyses, Computer-Assisted,Image Analysis, Computer Assisted,Image Processing, Biomedical,Image Processing, Computer Assisted,Image Processing, Digital,Image Processing, Medical,Image Processings, Medical,Image Reconstructions,Medical Image Processings,Processing, Biomedical Image,Processing, Digital Image,Processing, Medical Image,Processings, Digital Image,Processings, Medical Image,Reconstruction, Image,Reconstructions, Image
D008279 Magnetic Resonance Imaging Non-invasive method of demonstrating internal anatomy based on the principle that atomic nuclei in a strong magnetic field absorb pulses of radiofrequency energy and emit them as radiowaves which can be reconstructed into computerized images. The concept includes proton spin tomographic techniques. Chemical Shift Imaging,MR Tomography,MRI Scans,MRI, Functional,Magnetic Resonance Image,Magnetic Resonance Imaging, Functional,Magnetization Transfer Contrast Imaging,NMR Imaging,NMR Tomography,Tomography, NMR,Tomography, Proton Spin,fMRI,Functional Magnetic Resonance Imaging,Imaging, Chemical Shift,Proton Spin Tomography,Spin Echo Imaging,Steady-State Free Precession MRI,Tomography, MR,Zeugmatography,Chemical Shift Imagings,Echo Imaging, Spin,Echo Imagings, Spin,Functional MRI,Functional MRIs,Image, Magnetic Resonance,Imaging, Magnetic Resonance,Imaging, NMR,Imaging, Spin Echo,Imagings, Chemical Shift,Imagings, Spin Echo,MRI Scan,MRIs, Functional,Magnetic Resonance Images,Resonance Image, Magnetic,Scan, MRI,Scans, MRI,Shift Imaging, Chemical,Shift Imagings, Chemical,Spin Echo Imagings,Steady State Free Precession MRI
D008297 Male Males
D008875 Middle Aged An adult aged 45 - 64 years. Middle Age
D012107 Research Design A plan for collecting and utilizing data so that desired information can be obtained with sufficient precision or so that an hypothesis can be tested properly. Experimental Design,Data Adjustment,Data Reporting,Design, Experimental,Designs, Experimental,Error Sources,Experimental Designs,Matched Groups,Methodology, Research,Problem Formulation,Research Methodology,Research Proposal,Research Strategy,Research Technics,Research Techniques,Scoring Methods,Adjustment, Data,Adjustments, Data,Data Adjustments,Design, Research,Designs, Research,Error Source,Formulation, Problem,Formulations, Problem,Group, Matched,Groups, Matched,Matched Group,Method, Scoring,Methods, Scoring,Problem Formulations,Proposal, Research,Proposals, Research,Reporting, Data,Research Designs,Research Proposals,Research Strategies,Research Technic,Research Technique,Scoring Method,Source, Error,Sources, Error,Strategies, Research,Strategy, Research,Technic, Research,Technics, Research,Technique, Research,Techniques, Research
D005188 False Negative Reactions Negative test results in subjects who possess the attribute for which the test is conducted. The labeling of diseased persons as healthy when screening in the detection of disease. (Last, A Dictionary of Epidemiology, 2d ed) False Negative Reaction,Reaction, False Negative,Reactions, False Negative
D005189 False Positive Reactions Positive test results in subjects who do not possess the attribute for which the test is conducted. The labeling of healthy persons as diseased when screening in the detection of disease. (Last, A Dictionary of Epidemiology, 2d ed) False Positive Reaction,Positive Reaction, False,Positive Reactions, False,Reaction, False Positive,Reactions, False Positive
D005260 Female Females
D005858 Germany A country in central Europe, bordering the Baltic Sea and the North Sea, between the Netherlands and Poland, south of Denmark. The capital is Berlin.

Related Publications

S Waldt, and M Bruegel, and D Mueller, and K Holzapfel, and A B Imhoff, and E J Rummeny, and K Woertler
January 2010, Korean journal of radiology,
S Waldt, and M Bruegel, and D Mueller, and K Holzapfel, and A B Imhoff, and E J Rummeny, and K Woertler
March 2004, Skeletal radiology,
S Waldt, and M Bruegel, and D Mueller, and K Holzapfel, and A B Imhoff, and E J Rummeny, and K Woertler
February 1992, Radiology,
S Waldt, and M Bruegel, and D Mueller, and K Holzapfel, and A B Imhoff, and E J Rummeny, and K Woertler
May 1995, Radiology,
S Waldt, and M Bruegel, and D Mueller, and K Holzapfel, and A B Imhoff, and E J Rummeny, and K Woertler
December 2015, Skeletal radiology,
S Waldt, and M Bruegel, and D Mueller, and K Holzapfel, and A B Imhoff, and E J Rummeny, and K Woertler
June 1999, Investigative radiology,
S Waldt, and M Bruegel, and D Mueller, and K Holzapfel, and A B Imhoff, and E J Rummeny, and K Woertler
May 2017, Journal of clinical and diagnostic research : JCDR,
S Waldt, and M Bruegel, and D Mueller, and K Holzapfel, and A B Imhoff, and E J Rummeny, and K Woertler
January 2000, Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association,
S Waldt, and M Bruegel, and D Mueller, and K Holzapfel, and A B Imhoff, and E J Rummeny, and K Woertler
January 1994, Journal of computer assisted tomography,
S Waldt, and M Bruegel, and D Mueller, and K Holzapfel, and A B Imhoff, and E J Rummeny, and K Woertler
May 1994, Nihon Igaku Hoshasen Gakkai zasshi. Nippon acta radiologica,
Copied contents to your clipboard!