One-year follow-up of automatic adaptation of the rate response algorithm of the QT sensing, rate adaptive pacemaker. 1991

M W Baig, and W Boute, and M Begemann, and E J Perrins
Department of Medical Cardiology, General Infirmary at Leeds, England.

Optimal functioning of a rate adaptive pacemaker depends upon reliable sensing of the sensor and appropriate programming of the rate of response algorithm. QT sensing pacemakers use data derived from the endocardial electrogram in the programming of the rate response algorithm. In the latest versions of these pacemakers, programming of the rate response algorithm may be performed using either a semiautomatic Fast Learn (FL) procedure or by using the newly developed, fully Automatic Slope Adaptation (ASA) mechanism. We report our experience in a prospective study of 17 patients in the first year postimplantation. ASA was characterized by significant changes only in the values of the slope settings at the lower rate limit (3.7 msec/msec at time 0 to 5.77 msec/msec at 2 weeks, P less than 0.001) during the first 2 weeks after its enablement. Further adaptation between weeks 2 to 4 was observed (5.77 msec/msec to 6.4 msec/msec, P = 0.2) but this was not significant. The slope settings derived using the FL procedure were also checked at 2 and 4 weeks and were reproducible. They were closest in value to the values attained by the automated mechanism at 4 weeks. This suggests that the final value of the slope setting at the lower rate limit using ASA is reached between weeks 2 to 4. Both methods of slope determination result in satisfactory and similar rate response profiles but the time to achieve slope stability will necessarily be slower with ASA.

UI MeSH Term Description Entries
D008297 Male Males
D008875 Middle Aged An adult aged 45 - 64 years. Middle Age
D010138 Pacemaker, Artificial A device designed to stimulate, by electric impulses, contraction of the heart muscles. It may be temporary (external) or permanent (internal or internal-external). Cardiac Pacemaker, Artificial,Artificial Cardiac Pacemaker,Artificial Cardiac Pacemakers,Artificial Pacemaker,Artificial Pacemakers,Cardiac Pacemakers, Artificial,Pacemaker, Artificial Cardiac,Pacemakers, Artificial,Pacemakers, Artificial Cardiac
D002304 Cardiac Pacing, Artificial Regulation of the rate of contraction of the heart muscles by an artificial pacemaker. Pacing, Cardiac, Artificial,Artificial Cardiac Pacing,Artificial Cardiac Pacings,Cardiac Pacings, Artificial,Pacing, Artificial Cardiac,Pacings, Artificial Cardiac
D004562 Electrocardiography Recording of the moment-to-moment electromotive forces of the HEART as projected onto various sites on the body's surface, delineated as a scalar function of time. The recording is monitored by a tracing on slow moving chart paper or by observing it on a cardioscope, which is a CATHODE RAY TUBE DISPLAY. 12-Lead ECG,12-Lead EKG,12-Lead Electrocardiography,Cardiography,ECG,EKG,Electrocardiogram,Electrocardiograph,12 Lead ECG,12 Lead EKG,12 Lead Electrocardiography,12-Lead ECGs,12-Lead EKGs,12-Lead Electrocardiographies,Cardiographies,ECG, 12-Lead,EKG, 12-Lead,Electrocardiograms,Electrocardiographies, 12-Lead,Electrocardiographs,Electrocardiography, 12-Lead
D004867 Equipment Design Methods and patterns of fabricating machines and related hardware. Design, Equipment,Device Design,Medical Device Design,Design, Medical Device,Designs, Medical Device,Device Design, Medical,Device Designs, Medical,Medical Device Designs,Design, Device,Designs, Device,Designs, Equipment,Device Designs,Equipment Designs
D005080 Exercise Test Controlled physical activity which is performed in order to allow assessment of physiological functions, particularly cardiovascular and pulmonary, but also aerobic capacity. Maximal (most intense) exercise is usually required but submaximal exercise is also used. Arm Ergometry Test,Bicycle Ergometry Test,Cardiopulmonary Exercise Testing,Exercise Testing,Step Test,Stress Test,Treadmill Test,Cardiopulmonary Exercise Test,EuroFit Tests,Eurofit Test Battery,European Fitness Testing Battery,Fitness Testing,Physical Fitness Testing,Arm Ergometry Tests,Bicycle Ergometry Tests,Cardiopulmonary Exercise Tests,Ergometry Test, Arm,Ergometry Test, Bicycle,Ergometry Tests, Arm,Ergometry Tests, Bicycle,EuroFit Test,Eurofit Test Batteries,Exercise Test, Cardiopulmonary,Exercise Testing, Cardiopulmonary,Exercise Tests,Exercise Tests, Cardiopulmonary,Fitness Testing, Physical,Fitness Testings,Step Tests,Stress Tests,Test Battery, Eurofit,Test, Arm Ergometry,Test, Bicycle Ergometry,Test, Cardiopulmonary Exercise,Test, EuroFit,Test, Exercise,Test, Step,Test, Stress,Test, Treadmill,Testing, Cardiopulmonary Exercise,Testing, Exercise,Testing, Fitness,Testing, Physical Fitness,Tests, Arm Ergometry,Tests, Bicycle Ergometry,Tests, Cardiopulmonary Exercise,Tests, EuroFit,Tests, Exercise,Tests, Step,Tests, Stress,Tests, Treadmill,Treadmill Tests
D005260 Female Females
D005500 Follow-Up Studies Studies in which individuals or populations are followed to assess the outcome of exposures, procedures, or effects of a characteristic, e.g., occurrence of disease. Followup Studies,Follow Up Studies,Follow-Up Study,Followup Study,Studies, Follow-Up,Studies, Followup,Study, Follow-Up,Study, Followup
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man

Related Publications

M W Baig, and W Boute, and M Begemann, and E J Perrins
November 1993, American heart journal,
M W Baig, and W Boute, and M Begemann, and E J Perrins
January 1989, Pacing and clinical electrophysiology : PACE,
M W Baig, and W Boute, and M Begemann, and E J Perrins
June 1989, Journal of internal medicine,
M W Baig, and W Boute, and M Begemann, and E J Perrins
May 1992, The Veterinary record,
M W Baig, and W Boute, and M Begemann, and E J Perrins
November 1992, Pacing and clinical electrophysiology : PACE,
M W Baig, and W Boute, and M Begemann, and E J Perrins
November 1988, Pacing and clinical electrophysiology : PACE,
M W Baig, and W Boute, and M Begemann, and E J Perrins
January 1993, International surgery,
M W Baig, and W Boute, and M Begemann, and E J Perrins
January 2005, Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology,
M W Baig, and W Boute, and M Begemann, and E J Perrins
December 1990, Pacing and clinical electrophysiology : PACE,
M W Baig, and W Boute, and M Begemann, and E J Perrins
September 2020, European oral research,
Copied contents to your clipboard!