Intrathoracic impedance monitoring to predict decompensated heart failure. 2007

Claudia Ypenburg, and Jeroen J Bax, and Ernst E van der Wall, and Martin J Schalij, and Lieselot van Erven
Department of Cardiology, Leiden University Medical Center, Leiden, The Netherlands. c.ypenburg@lumc.nl

Intrathoracic impedance measurement has been introduced in the InSync Sentry biventricular implantable cardioverter-defibrillator and may permit the early identification of pulmonary fluid accumulation secondary to left-sided heart failure (HF). An audible alarm (the OptiVol alert) can be triggered when the impedance index increases to greater than a predefined level of 60 Omega . day. The aim of this study was to evaluate the clinical value of the OptiVol alert and its prediction for decompensated HF. One hundred fifteen consecutive patients (mean New York Heart Association class 2.8 +/- 0.5, mean left ventricular ejection fraction 26 +/- 8%) who received InSync Sentry biventricular implantable cardioverter-defibrillators were included. When presenting with the OptiVol alert, current hemodynamic status was evaluated. During follow-up (mean 9 +/- 5 months), there were 45 presentations with the OptiVol alert in 30 patients. Clinical signs and symptoms of HF were present in only 15 patients (33%), whereas in the remaining patients, clinical signs of HF were absent (p <0.05). Receiver-operating characteristic curve analysis showed that increasing the threshold for the OptiVol alert provided a substantial increase in specificity for the detection of HF, with the optimal cut-off value identified at 120 Omega . day, yielding sensitivity of 60% and specificity of 73%. In conclusion, intrathoracic impedance measurement as present in the InSync Sentry biventricular implantable cardioverter-defibrillator may be a useful tool for monitoring pulmonary fluid status. The proposed threshold for the OptiVol alert of 60 Omega. day is very sensitive but not specific for the assessment of HF; adjustment of threshold settings may yield a superior balance between sensitivity and specificity.

UI MeSH Term Description Entries
D008297 Male Males
D008991 Monitoring, Physiologic The continuous measurement of physiological processes, blood pressure, heart rate, renal output, reflexes, respiration, etc., in a patient or experimental animal; includes pharmacologic monitoring, the measurement of administered drugs or their metabolites in the blood, tissues, or urine. Patient Monitoring,Monitoring, Physiological,Physiologic Monitoring,Monitoring, Patient,Physiological Monitoring
D011237 Predictive Value of Tests In screening and diagnostic tests, the probability that a person with a positive test is a true positive (i.e., has the disease), is referred to as the predictive value of a positive test; whereas, the predictive value of a negative test is the probability that the person with a negative test does not have the disease. Predictive value is related to the sensitivity and specificity of the test. Negative Predictive Value,Positive Predictive Value,Predictive Value Of Test,Predictive Values Of Tests,Negative Predictive Values,Positive Predictive Values,Predictive Value, Negative,Predictive Value, Positive
D002307 Cardiography, Impedance A type of impedance plethysmography in which bioelectrical impedance is measured between electrodes positioned around the neck and around the lower thorax. It is used principally to calculate stroke volume and cardiac volume, but it is also related to myocardial contractility, thoracic fluid content, and circulation to the extremities. Impedance, Transthoracic,Plethysmography, Impedance, Transthoracic,Impedance Cardiography,Impedance Plethysmography, Transthoracic,Plethysmography, Transthoracic Impedance,Transthoracic Impedance Plethysmography,Cardiographies, Impedance,Impedance Cardiographies,Impedance Plethysmographies, Transthoracic,Impedances, Transthoracic,Plethysmographies, Transthoracic Impedance,Transthoracic Impedance,Transthoracic Impedance Plethysmographies,Transthoracic Impedances
D005260 Female Females
D006333 Heart Failure A heterogeneous condition in which the heart is unable to pump out sufficient blood to meet the metabolic need of the body. Heart failure can be caused by structural defects, functional abnormalities (VENTRICULAR DYSFUNCTION), or a sudden overload beyond its capacity. Chronic heart failure is more common than acute heart failure which results from sudden insult to cardiac function, such as MYOCARDIAL INFARCTION. Cardiac Failure,Heart Decompensation,Congestive Heart Failure,Heart Failure, Congestive,Heart Failure, Left-Sided,Heart Failure, Right-Sided,Left-Sided Heart Failure,Myocardial Failure,Right-Sided Heart Failure,Decompensation, Heart,Heart Failure, Left Sided,Heart Failure, Right Sided,Left Sided Heart Failure,Right Sided Heart Failure
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D000368 Aged A person 65 years of age or older. For a person older than 79 years, AGED, 80 AND OVER is available. Elderly
D012372 ROC Curve A graphic means for assessing the ability of a screening test to discriminate between healthy and diseased persons; may also be used in other studies, e.g., distinguishing stimuli responses as to a faint stimuli or nonstimuli. ROC Analysis,Receiver Operating Characteristic,Analysis, ROC,Analyses, ROC,Characteristic, Receiver Operating,Characteristics, Receiver Operating,Curve, ROC,Curves, ROC,ROC Analyses,ROC Curves,Receiver Operating Characteristics
D017147 Defibrillators, Implantable Implantable devices which continuously monitor the electrical activity of the heart and automatically detect and terminate ventricular tachycardia (TACHYCARDIA, VENTRICULAR) and VENTRICULAR FIBRILLATION. They consist of an impulse generator, batteries, and electrodes. Cardioverter-Defibrillators, Implantable,Implantable Cardioverter Defibrillator,Implantable Cardioverter-Defibrillators,Implantable Defibrillators,Cardioverter Defibrillator, Implantable,Cardioverter Defibrillators, Implantable,Cardioverter-Defibrillator, Implantable,Defibrillator, Implantable,Defibrillator, Implantable Cardioverter,Defibrillators, Implantable Cardioverter,Implantable Cardioverter Defibrillators,Implantable Cardioverter-Defibrillator,Implantable Defibrillator

Related Publications

Claudia Ypenburg, and Jeroen J Bax, and Ernst E van der Wall, and Martin J Schalij, and Lieselot van Erven
May 2007, The American journal of cardiology,
Claudia Ypenburg, and Jeroen J Bax, and Ernst E van der Wall, and Martin J Schalij, and Lieselot van Erven
January 2007, Congestive heart failure (Greenwich, Conn.),
Claudia Ypenburg, and Jeroen J Bax, and Ernst E van der Wall, and Martin J Schalij, and Lieselot van Erven
August 2011, Pacing and clinical electrophysiology : PACE,
Claudia Ypenburg, and Jeroen J Bax, and Ernst E van der Wall, and Martin J Schalij, and Lieselot van Erven
January 2010, Dimensions of critical care nursing : DCCN,
Claudia Ypenburg, and Jeroen J Bax, and Ernst E van der Wall, and Martin J Schalij, and Lieselot van Erven
January 2007, European journal of heart failure,
Claudia Ypenburg, and Jeroen J Bax, and Ernst E van der Wall, and Martin J Schalij, and Lieselot van Erven
January 2012, Circulation journal : official journal of the Japanese Circulation Society,
Claudia Ypenburg, and Jeroen J Bax, and Ernst E van der Wall, and Martin J Schalij, and Lieselot van Erven
October 2011, Circulation,
Claudia Ypenburg, and Jeroen J Bax, and Ernst E van der Wall, and Martin J Schalij, and Lieselot van Erven
May 2010, Circulation. Heart failure,
Claudia Ypenburg, and Jeroen J Bax, and Ernst E van der Wall, and Martin J Schalij, and Lieselot van Erven
January 2012, Circulation journal : official journal of the Japanese Circulation Society,
Claudia Ypenburg, and Jeroen J Bax, and Ernst E van der Wall, and Martin J Schalij, and Lieselot van Erven
March 2009, Pacing and clinical electrophysiology : PACE,
Copied contents to your clipboard!