Incidence and mechanism of interruption of reentrant ventricular tachycardia with rapid ventricular pacing. 1992

Y Aizawa, and S Niwano, and M Chinushi, and M Tamura, and Y Kusano, and T Miyajima, and H Kitazawa, and A Shibata
First Department of Internal Medicine, Niigata University School of Medicine, Japan.

BACKGROUND Information concerning the electrophysiological characteristics of the reentrant circuit is still limited. To understand the incidence and mechanism of pacing-induced interruption of ventricular tachycardia (VT), rapid pacing was performed to entrain VT, and the local electrogram at the VT origin and the surface electrocardiogram were analyzed. RESULTS Among 25 patients, evidence of transient entrainment was confirmed in 20 patients, but the critical paced cycle length at which VT was interrupted was obtained in 13 patients when the paced cycle length was decreased in steps of 10 msec. During pacing at the critical cycle length (defined as block cycle length), changes in the local electrogram at VT origin were confirmed in all of the 13 patients; that is, 1) a change in morphology and 2) a change in the timing of activation: a sudden shortening in the stimulus to local electrogram time (third entrainment criterion by Waldo). The two changes mean that the exit is activated from a different direction (retrograde capture) because of an orthodromic block in the slow conduction zone. The QRS complex in the surface electrocardiogram showed a change in configuration from the fusion complex to the fully paced one at the same time when the exit was captured antidromically. CONCLUSIONS Based on our observations in these patients, ventricular tachycardia interruption is very often associated with orthodromic block in the reentrant circuit at a critical cycle length of rapid pacing.

UI MeSH Term Description Entries
D008297 Male Males
D008875 Middle Aged An adult aged 45 - 64 years. Middle Age
D002304 Cardiac Pacing, Artificial Regulation of the rate of contraction of the heart muscles by an artificial pacemaker. Pacing, Cardiac, Artificial,Artificial Cardiac Pacing,Artificial Cardiac Pacings,Cardiac Pacings, Artificial,Pacing, Artificial Cardiac,Pacings, Artificial Cardiac
D002648 Child A person 6 to 12 years of age. An individual 2 to 5 years old is CHILD, PRESCHOOL. Children
D004562 Electrocardiography Recording of the moment-to-moment electromotive forces of the HEART as projected onto various sites on the body's surface, delineated as a scalar function of time. The recording is monitored by a tracing on slow moving chart paper or by observing it on a cardioscope, which is a CATHODE RAY TUBE DISPLAY. 12-Lead ECG,12-Lead EKG,12-Lead Electrocardiography,Cardiography,ECG,EKG,Electrocardiogram,Electrocardiograph,12 Lead ECG,12 Lead EKG,12 Lead Electrocardiography,12-Lead ECGs,12-Lead EKGs,12-Lead Electrocardiographies,Cardiographies,ECG, 12-Lead,EKG, 12-Lead,Electrocardiograms,Electrocardiographies, 12-Lead,Electrocardiographs,Electrocardiography, 12-Lead
D005260 Female Females
D006324 Heart Arrest, Induced A procedure to stop the contraction of MYOCARDIUM during HEART SURGERY. It is usually achieved with the use of chemicals (CARDIOPLEGIC SOLUTIONS) or cold temperature (such as chilled perfusate). Cardiac Arrest, Induced,Cardioplegia,Induced Cardiac Arrest,Induced Heart Arrest,Cardioplegias
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D000293 Adolescent A person 13 to 18 years of age. Adolescence,Youth,Adolescents,Adolescents, Female,Adolescents, Male,Teenagers,Teens,Adolescent, Female,Adolescent, Male,Female Adolescent,Female Adolescents,Male Adolescent,Male Adolescents,Teen,Teenager,Youths
D000328 Adult A person having attained full growth or maturity. Adults are of 19 through 44 years of age. For a person between 19 and 24 years of age, YOUNG ADULT is available. Adults

Related Publications

Y Aizawa, and S Niwano, and M Chinushi, and M Tamura, and Y Kusano, and T Miyajima, and H Kitazawa, and A Shibata
February 1984, Journal of the American College of Cardiology,
Y Aizawa, and S Niwano, and M Chinushi, and M Tamura, and Y Kusano, and T Miyajima, and H Kitazawa, and A Shibata
November 1984, Journal of the American College of Cardiology,
Y Aizawa, and S Niwano, and M Chinushi, and M Tamura, and Y Kusano, and T Miyajima, and H Kitazawa, and A Shibata
November 1984, Journal of the American College of Cardiology,
Y Aizawa, and S Niwano, and M Chinushi, and M Tamura, and Y Kusano, and T Miyajima, and H Kitazawa, and A Shibata
April 1995, Journal of electrocardiology,
Y Aizawa, and S Niwano, and M Chinushi, and M Tamura, and Y Kusano, and T Miyajima, and H Kitazawa, and A Shibata
November 2014, Pacing and clinical electrophysiology : PACE,
Y Aizawa, and S Niwano, and M Chinushi, and M Tamura, and Y Kusano, and T Miyajima, and H Kitazawa, and A Shibata
January 1978, The American journal of cardiology,
Y Aizawa, and S Niwano, and M Chinushi, and M Tamura, and Y Kusano, and T Miyajima, and H Kitazawa, and A Shibata
October 1992, Journal of electrocardiology,
Y Aizawa, and S Niwano, and M Chinushi, and M Tamura, and Y Kusano, and T Miyajima, and H Kitazawa, and A Shibata
July 1999, Japanese heart journal,
Y Aizawa, and S Niwano, and M Chinushi, and M Tamura, and Y Kusano, and T Miyajima, and H Kitazawa, and A Shibata
August 1980, Circulation,
Y Aizawa, and S Niwano, and M Chinushi, and M Tamura, and Y Kusano, and T Miyajima, and H Kitazawa, and A Shibata
September 1994, Japanese heart journal,
Copied contents to your clipboard!