Free serum cortisol: quantification applying equilibrium dialysis or ultrafiltration and an automated immunoassay system. 2007

Michael Vogeser, and Patrick Möhnle, and Josef Briegel
Institute of Clinical Chemistry, Hospital of the University of Munich, Munich, Germany. Michael.Vogeser@med.uni-muenchen.de

BACKGROUND Quantification of bioactive, free serum cortisol concentrations can characterize adrenocortical function more appropriately compared to total serum cortisol measurement. Ultrafiltration or equilibrium dialysis of serum samples allow direct measurement of free serum cortisol concentrations but respective methods have poorly been validated so far. The aim of our study was to investigate the analytical performance of free serum cortisol measurement employing equilibrium dialysis and ultrafiltration. METHODS Two commercially available ultrafiltration devices and self-assembled dialysis cells, respectively, were studied. Cortisol was quantified in filtrate or dialysate using an automated immunoassay system. Using two serum pools, the inter-assay coefficient of variation was determined for the three methods and a method comparison was performed. RESULTS Inter-assay coefficients of variation (n=10) between 3.2% and 14.8% were observed in the imprecision study. Method comparison demonstrated close agreement between free serum cortisol results obtained by ultrafiltration and equilibrium dialysis, respectively (equilibrium dialysis=1.2xultrafiltration+3.9 nmol/L; r=0.99; n=35). CONCLUSIONS Direct quantification of free serum cortisol after equilibrium dialysis or ultrafiltration of the samples offers acceptable reproducibility and results in close agreement can be obtained. Both methods can potentially be introduced into a routine laboratory setting.

UI MeSH Term Description Entries
D007118 Immunoassay A technique using antibodies for identifying or quantifying a substance. Usually the substance being studied serves as antigen both in antibody production and in measurement of antibody by the test substance. Immunochromatographic Assay,Assay, Immunochromatographic,Assays, Immunochromatographic,Immunoassays,Immunochromatographic Assays
D003956 Dialysis A process of selective diffusion through a membrane. It is usually used to separate low-molecular-weight solutes which diffuse through the membrane from the colloidal and high-molecular-weight solutes which do not. (McGraw-Hill Dictionary of Scientific and Technical Terms, 4th ed) Dialyses
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D006854 Hydrocortisone The main glucocorticoid secreted by the ADRENAL CORTEX. Its synthetic counterpart is used, either as an injection or topically, in the treatment of inflammation, allergy, collagen diseases, asthma, adrenocortical deficiency, shock, and some neoplastic conditions. Cortef,Cortisol,Pregn-4-ene-3,20-dione, 11,17,21-trihydroxy-, (11beta)-,11-Epicortisol,Cortifair,Cortril,Epicortisol,Hydrocortisone, (11 alpha)-Isomer,Hydrocortisone, (9 beta,10 alpha,11 alpha)-Isomer,11 Epicortisol
D001331 Automation Controlled operation of an apparatus, process, or system by mechanical or electronic devices that take the place of human organs of observation, effort, and decision. (From Webster's Collegiate Dictionary, 1993) Automations
D014462 Ultrafiltration The separation of particles from a suspension by passage through a filter with very fine pores. In ultrafiltration the separation is accomplished by convective transport; in DIALYSIS separation relies instead upon differential diffusion. Ultrafiltration occurs naturally and is a laboratory procedure. Artificial ultrafiltration of the blood is referred to as HEMOFILTRATION or HEMODIAFILTRATION (if combined with HEMODIALYSIS).
D015203 Reproducibility of Results The statistical reproducibility of measurements (often in a clinical context), including the testing of instrumentation or techniques to obtain reproducible results. The concept includes reproducibility of physiological measurements, which may be used to develop rules to assess probability or prognosis, or response to a stimulus; reproducibility of occurrence of a condition; and reproducibility of experimental results. Reliability and Validity,Reliability of Result,Reproducibility Of Result,Reproducibility of Finding,Validity of Result,Validity of Results,Face Validity,Reliability (Epidemiology),Reliability of Results,Reproducibility of Findings,Test-Retest Reliability,Validity (Epidemiology),Finding Reproducibilities,Finding Reproducibility,Of Result, Reproducibility,Of Results, Reproducibility,Reliabilities, Test-Retest,Reliability, Test-Retest,Result Reliabilities,Result Reliability,Result Validities,Result Validity,Result, Reproducibility Of,Results, Reproducibility Of,Test Retest Reliability,Validity and Reliability,Validity, Face

Related Publications

Michael Vogeser, and Patrick Möhnle, and Josef Briegel
January 1978, The Journal of nuclear medicine and allied sciences,
Michael Vogeser, and Patrick Möhnle, and Josef Briegel
December 1993, Clinical chemistry,
Michael Vogeser, and Patrick Möhnle, and Josef Briegel
July 1994, Scandinavian journal of clinical and laboratory investigation,
Michael Vogeser, and Patrick Möhnle, and Josef Briegel
January 1984, Clinical pharmacokinetics,
Michael Vogeser, and Patrick Möhnle, and Josef Briegel
July 1991, Kaku igaku. The Japanese journal of nuclear medicine,
Michael Vogeser, and Patrick Möhnle, and Josef Briegel
August 2020, Clinica chimica acta; international journal of clinical chemistry,
Michael Vogeser, and Patrick Möhnle, and Josef Briegel
June 1982, Clinical chemistry,
Michael Vogeser, and Patrick Möhnle, and Josef Briegel
July 1982, Clinical chemistry,
Michael Vogeser, and Patrick Möhnle, and Josef Briegel
November 1988, The Journal of clinical endocrinology and metabolism,
Copied contents to your clipboard!